Determination of the radiochemical purity of 99mTc medronate injection by thin layer chromatography on iTLC-SG: effect of medronate concentration on the value measured
Background When using iTLC‐SG thin layer chromatography plates to measure radiochemical impurities in 99mTc medronate, falsely high values were obtained for 99mTc pertechnetate impurity. Preliminary investigations indicated that the mass of 99mTc medronate applied to the plate influences the value....
Saved in:
Published in: | Journal of labelled compounds & radiopharmaceuticals 2013-05, Vol.56 (5), p.301-304 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background
When using iTLC‐SG thin layer chromatography plates to measure radiochemical impurities in 99mTc medronate, falsely high values were obtained for 99mTc pertechnetate impurity. Preliminary investigations indicated that the mass of 99mTc medronate applied to the plate influences the value.
Aim
The goal of this study was to determine if the concentration of medronate influences the value obtained for 99mTc pertechnetate impurity.
Experimental
99mTc medronate was prepared at two concentrations: 4 mg/mL and 0.2 mg/mL. Impurity levels were measured using three stationary phases: dried and undried iTLC‐SG and 54SFC paper. Two mobile phases were used: methyl ethyl ketone to detect 99mTc pertechnetate and sodium acetate 136 g/L to detect hydrolysed and colloidal 99mTc. Sample spot drying and volume were also investigated.
Results
With 4 mg/mL samples, the three stationary phases measured similar impurity levels (p > 0.05). With the 0.2 mg/mL samples, higher levels of 99mTc pertechnetate were measured with iTLC‐SG than with paper (p |
---|---|