Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry
A simple method for hydrogen/deuterium exchange in a standard electrospray (ESI) ionization source is presented. In this method, a D2O droplet is placed between the ESI needle and the entrance of the mass spectrometer and thus saturation of the atmosphere with deuterated vapor in the ESI region is a...
Saved in:
Published in: | Analytical chemistry (Washington) 2013-06, Vol.85 (11), p.5330-5334 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573 |
---|---|
cites | cdi_FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573 |
container_end_page | 5334 |
container_issue | 11 |
container_start_page | 5330 |
container_title | Analytical chemistry (Washington) |
container_volume | 85 |
creator | Kostyukevich, Yury Kononikhin, Alexey Popov, Igor Nikolaev, Eugene |
description | A simple method for hydrogen/deuterium exchange in a standard electrospray (ESI) ionization source is presented. In this method, a D2O droplet is placed between the ESI needle and the entrance of the mass spectrometer and thus saturation of the atmosphere with deuterated vapor in the ESI region is achieved. It was shown that full exchange of up to 23 labile acidic hydrogens with a minimal back exchange with the surrounding atmospheric water can be performed by this method. |
doi_str_mv | 10.1021/ac4006606 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1365656625</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2990126481</sourcerecordid><originalsourceid>FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573</originalsourceid><addsrcrecordid>eNplkE9LwzAYh4Mobk4PfgEJiAcPdW-SNe2OY1Y32PAwPZckS7eOtalJC9YP4Oc2uj8I8h4Cb548v_BD6JrAAwFK-kINADgHfoK6JKQQ8Dimp6gLACygEUAHXTi3ASAECD9HHcr4ICLAu-hrkRfVVuNRXRhXrbXNFZ60S2tWuuw_6qb2m6bAyYdai3Kl8VzXa7PEmbE4KZtCW1HnpsQmwzMhcy86PHZYtjjZalVbL7aixVNT5p87fC6cw4vq97LQtW0v0Vkmtk5f7c8eentKXseTYPbyPB2PZoFgEa8DJlkYRxmwoVIiFLFYhmKY6QGLqAZFMwXDUEo9iCWnchgxQRgVMQWQHCALI9ZDtztvZc17o12dbkxjSx-ZEsZDP5yGnrrfUcr_3VmdpZXNC2HblED603h6bNyzN3tjIwu9PJKHij1wtwOEcn_S_om-Aa5kiKM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1365656625</pqid></control><display><type>article</type><title>Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)</source><creator>Kostyukevich, Yury ; Kononikhin, Alexey ; Popov, Igor ; Nikolaev, Eugene</creator><creatorcontrib>Kostyukevich, Yury ; Kononikhin, Alexey ; Popov, Igor ; Nikolaev, Eugene</creatorcontrib><description>A simple method for hydrogen/deuterium exchange in a standard electrospray (ESI) ionization source is presented. In this method, a D2O droplet is placed between the ESI needle and the entrance of the mass spectrometer and thus saturation of the atmosphere with deuterated vapor in the ESI region is achieved. It was shown that full exchange of up to 23 labile acidic hydrogens with a minimal back exchange with the surrounding atmospheric water can be performed by this method.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac4006606</identifier><identifier>PMID: 23647106</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Analytical chemistry ; Atmosphere ; Deuterium - chemistry ; Deuterium Exchange Measurement ; Hydrogen ; Hydrogen - chemistry ; Mass spectrometry ; Spectrometry, Mass, Electrospray Ionization - methods ; Water - chemistry</subject><ispartof>Analytical chemistry (Washington), 2013-06, Vol.85 (11), p.5330-5334</ispartof><rights>Copyright © 2013 American Chemical Society</rights><rights>Copyright American Chemical Society Jun 4, 2013</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573</citedby><cites>FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23647106$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kostyukevich, Yury</creatorcontrib><creatorcontrib>Kononikhin, Alexey</creatorcontrib><creatorcontrib>Popov, Igor</creatorcontrib><creatorcontrib>Nikolaev, Eugene</creatorcontrib><title>Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>A simple method for hydrogen/deuterium exchange in a standard electrospray (ESI) ionization source is presented. In this method, a D2O droplet is placed between the ESI needle and the entrance of the mass spectrometer and thus saturation of the atmosphere with deuterated vapor in the ESI region is achieved. It was shown that full exchange of up to 23 labile acidic hydrogens with a minimal back exchange with the surrounding atmospheric water can be performed by this method.</description><subject>Analytical chemistry</subject><subject>Atmosphere</subject><subject>Deuterium - chemistry</subject><subject>Deuterium Exchange Measurement</subject><subject>Hydrogen</subject><subject>Hydrogen - chemistry</subject><subject>Mass spectrometry</subject><subject>Spectrometry, Mass, Electrospray Ionization - methods</subject><subject>Water - chemistry</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNplkE9LwzAYh4Mobk4PfgEJiAcPdW-SNe2OY1Y32PAwPZckS7eOtalJC9YP4Oc2uj8I8h4Cb548v_BD6JrAAwFK-kINADgHfoK6JKQQ8Dimp6gLACygEUAHXTi3ASAECD9HHcr4ICLAu-hrkRfVVuNRXRhXrbXNFZ60S2tWuuw_6qb2m6bAyYdai3Kl8VzXa7PEmbE4KZtCW1HnpsQmwzMhcy86PHZYtjjZalVbL7aixVNT5p87fC6cw4vq97LQtW0v0Vkmtk5f7c8eentKXseTYPbyPB2PZoFgEa8DJlkYRxmwoVIiFLFYhmKY6QGLqAZFMwXDUEo9iCWnchgxQRgVMQWQHCALI9ZDtztvZc17o12dbkxjSx-ZEsZDP5yGnrrfUcr_3VmdpZXNC2HblED603h6bNyzN3tjIwu9PJKHij1wtwOEcn_S_om-Aa5kiKM</recordid><startdate>20130604</startdate><enddate>20130604</enddate><creator>Kostyukevich, Yury</creator><creator>Kononikhin, Alexey</creator><creator>Popov, Igor</creator><creator>Nikolaev, Eugene</creator><general>American Chemical Society</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope></search><sort><creationdate>20130604</creationdate><title>Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry</title><author>Kostyukevich, Yury ; Kononikhin, Alexey ; Popov, Igor ; Nikolaev, Eugene</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Analytical chemistry</topic><topic>Atmosphere</topic><topic>Deuterium - chemistry</topic><topic>Deuterium Exchange Measurement</topic><topic>Hydrogen</topic><topic>Hydrogen - chemistry</topic><topic>Mass spectrometry</topic><topic>Spectrometry, Mass, Electrospray Ionization - methods</topic><topic>Water - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kostyukevich, Yury</creatorcontrib><creatorcontrib>Kononikhin, Alexey</creatorcontrib><creatorcontrib>Popov, Igor</creatorcontrib><creatorcontrib>Nikolaev, Eugene</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kostyukevich, Yury</au><au>Kononikhin, Alexey</au><au>Popov, Igor</au><au>Nikolaev, Eugene</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2013-06-04</date><risdate>2013</risdate><volume>85</volume><issue>11</issue><spage>5330</spage><epage>5334</epage><pages>5330-5334</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>A simple method for hydrogen/deuterium exchange in a standard electrospray (ESI) ionization source is presented. In this method, a D2O droplet is placed between the ESI needle and the entrance of the mass spectrometer and thus saturation of the atmosphere with deuterated vapor in the ESI region is achieved. It was shown that full exchange of up to 23 labile acidic hydrogens with a minimal back exchange with the surrounding atmospheric water can be performed by this method.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>23647106</pmid><doi>10.1021/ac4006606</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-2700 |
ispartof | Analytical chemistry (Washington), 2013-06, Vol.85 (11), p.5330-5334 |
issn | 0003-2700 1520-6882 |
language | eng |
recordid | cdi_proquest_journals_1365656625 |
source | American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list) |
subjects | Analytical chemistry Atmosphere Deuterium - chemistry Deuterium Exchange Measurement Hydrogen Hydrogen - chemistry Mass spectrometry Spectrometry, Mass, Electrospray Ionization - methods Water - chemistry |
title | Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T07%3A07%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simple%20Atmospheric%20Hydrogen/Deuterium%20Exchange%20Method%20for%20Enumeration%20of%20Labile%20Hydrogens%20by%20Electrospray%20Ionization%20Mass%20Spectrometry&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Kostyukevich,%20Yury&rft.date=2013-06-04&rft.volume=85&rft.issue=11&rft.spage=5330&rft.epage=5334&rft.pages=5330-5334&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac4006606&rft_dat=%3Cproquest_cross%3E2990126481%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1365656625&rft_id=info:pmid/23647106&rfr_iscdi=true |