Loading…

Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry

A simple method for hydrogen/deuterium exchange in a standard electrospray (ESI) ionization source is presented. In this method, a D2O droplet is placed between the ESI needle and the entrance of the mass spectrometer and thus saturation of the atmosphere with deuterated vapor in the ESI region is a...

Full description

Saved in:
Bibliographic Details
Published in:Analytical chemistry (Washington) 2013-06, Vol.85 (11), p.5330-5334
Main Authors: Kostyukevich, Yury, Kononikhin, Alexey, Popov, Igor, Nikolaev, Eugene
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573
cites cdi_FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573
container_end_page 5334
container_issue 11
container_start_page 5330
container_title Analytical chemistry (Washington)
container_volume 85
creator Kostyukevich, Yury
Kononikhin, Alexey
Popov, Igor
Nikolaev, Eugene
description A simple method for hydrogen/deuterium exchange in a standard electrospray (ESI) ionization source is presented. In this method, a D2O droplet is placed between the ESI needle and the entrance of the mass spectrometer and thus saturation of the atmosphere with deuterated vapor in the ESI region is achieved. It was shown that full exchange of up to 23 labile acidic hydrogens with a minimal back exchange with the surrounding atmospheric water can be performed by this method.
doi_str_mv 10.1021/ac4006606
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1365656625</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2990126481</sourcerecordid><originalsourceid>FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573</originalsourceid><addsrcrecordid>eNplkE9LwzAYh4Mobk4PfgEJiAcPdW-SNe2OY1Y32PAwPZckS7eOtalJC9YP4Oc2uj8I8h4Cb548v_BD6JrAAwFK-kINADgHfoK6JKQQ8Dimp6gLACygEUAHXTi3ASAECD9HHcr4ICLAu-hrkRfVVuNRXRhXrbXNFZ60S2tWuuw_6qb2m6bAyYdai3Kl8VzXa7PEmbE4KZtCW1HnpsQmwzMhcy86PHZYtjjZalVbL7aixVNT5p87fC6cw4vq97LQtW0v0Vkmtk5f7c8eentKXseTYPbyPB2PZoFgEa8DJlkYRxmwoVIiFLFYhmKY6QGLqAZFMwXDUEo9iCWnchgxQRgVMQWQHCALI9ZDtztvZc17o12dbkxjSx-ZEsZDP5yGnrrfUcr_3VmdpZXNC2HblED603h6bNyzN3tjIwu9PJKHij1wtwOEcn_S_om-Aa5kiKM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1365656625</pqid></control><display><type>article</type><title>Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry</title><source>American Chemical Society:Jisc Collections:American Chemical Society Read &amp; Publish Agreement 2022-2024 (Reading list)</source><creator>Kostyukevich, Yury ; Kononikhin, Alexey ; Popov, Igor ; Nikolaev, Eugene</creator><creatorcontrib>Kostyukevich, Yury ; Kononikhin, Alexey ; Popov, Igor ; Nikolaev, Eugene</creatorcontrib><description>A simple method for hydrogen/deuterium exchange in a standard electrospray (ESI) ionization source is presented. In this method, a D2O droplet is placed between the ESI needle and the entrance of the mass spectrometer and thus saturation of the atmosphere with deuterated vapor in the ESI region is achieved. It was shown that full exchange of up to 23 labile acidic hydrogens with a minimal back exchange with the surrounding atmospheric water can be performed by this method.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac4006606</identifier><identifier>PMID: 23647106</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Analytical chemistry ; Atmosphere ; Deuterium - chemistry ; Deuterium Exchange Measurement ; Hydrogen ; Hydrogen - chemistry ; Mass spectrometry ; Spectrometry, Mass, Electrospray Ionization - methods ; Water - chemistry</subject><ispartof>Analytical chemistry (Washington), 2013-06, Vol.85 (11), p.5330-5334</ispartof><rights>Copyright © 2013 American Chemical Society</rights><rights>Copyright American Chemical Society Jun 4, 2013</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573</citedby><cites>FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23647106$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kostyukevich, Yury</creatorcontrib><creatorcontrib>Kononikhin, Alexey</creatorcontrib><creatorcontrib>Popov, Igor</creatorcontrib><creatorcontrib>Nikolaev, Eugene</creatorcontrib><title>Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>A simple method for hydrogen/deuterium exchange in a standard electrospray (ESI) ionization source is presented. In this method, a D2O droplet is placed between the ESI needle and the entrance of the mass spectrometer and thus saturation of the atmosphere with deuterated vapor in the ESI region is achieved. It was shown that full exchange of up to 23 labile acidic hydrogens with a minimal back exchange with the surrounding atmospheric water can be performed by this method.</description><subject>Analytical chemistry</subject><subject>Atmosphere</subject><subject>Deuterium - chemistry</subject><subject>Deuterium Exchange Measurement</subject><subject>Hydrogen</subject><subject>Hydrogen - chemistry</subject><subject>Mass spectrometry</subject><subject>Spectrometry, Mass, Electrospray Ionization - methods</subject><subject>Water - chemistry</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNplkE9LwzAYh4Mobk4PfgEJiAcPdW-SNe2OY1Y32PAwPZckS7eOtalJC9YP4Oc2uj8I8h4Cb548v_BD6JrAAwFK-kINADgHfoK6JKQQ8Dimp6gLACygEUAHXTi3ASAECD9HHcr4ICLAu-hrkRfVVuNRXRhXrbXNFZ60S2tWuuw_6qb2m6bAyYdai3Kl8VzXa7PEmbE4KZtCW1HnpsQmwzMhcy86PHZYtjjZalVbL7aixVNT5p87fC6cw4vq97LQtW0v0Vkmtk5f7c8eentKXseTYPbyPB2PZoFgEa8DJlkYRxmwoVIiFLFYhmKY6QGLqAZFMwXDUEo9iCWnchgxQRgVMQWQHCALI9ZDtztvZc17o12dbkxjSx-ZEsZDP5yGnrrfUcr_3VmdpZXNC2HblED603h6bNyzN3tjIwu9PJKHij1wtwOEcn_S_om-Aa5kiKM</recordid><startdate>20130604</startdate><enddate>20130604</enddate><creator>Kostyukevich, Yury</creator><creator>Kononikhin, Alexey</creator><creator>Popov, Igor</creator><creator>Nikolaev, Eugene</creator><general>American Chemical Society</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope></search><sort><creationdate>20130604</creationdate><title>Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry</title><author>Kostyukevich, Yury ; Kononikhin, Alexey ; Popov, Igor ; Nikolaev, Eugene</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Analytical chemistry</topic><topic>Atmosphere</topic><topic>Deuterium - chemistry</topic><topic>Deuterium Exchange Measurement</topic><topic>Hydrogen</topic><topic>Hydrogen - chemistry</topic><topic>Mass spectrometry</topic><topic>Spectrometry, Mass, Electrospray Ionization - methods</topic><topic>Water - chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kostyukevich, Yury</creatorcontrib><creatorcontrib>Kononikhin, Alexey</creatorcontrib><creatorcontrib>Popov, Igor</creatorcontrib><creatorcontrib>Nikolaev, Eugene</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kostyukevich, Yury</au><au>Kononikhin, Alexey</au><au>Popov, Igor</au><au>Nikolaev, Eugene</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>2013-06-04</date><risdate>2013</risdate><volume>85</volume><issue>11</issue><spage>5330</spage><epage>5334</epage><pages>5330-5334</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>A simple method for hydrogen/deuterium exchange in a standard electrospray (ESI) ionization source is presented. In this method, a D2O droplet is placed between the ESI needle and the entrance of the mass spectrometer and thus saturation of the atmosphere with deuterated vapor in the ESI region is achieved. It was shown that full exchange of up to 23 labile acidic hydrogens with a minimal back exchange with the surrounding atmospheric water can be performed by this method.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>23647106</pmid><doi>10.1021/ac4006606</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 2013-06, Vol.85 (11), p.5330-5334
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_journals_1365656625
source American Chemical Society:Jisc Collections:American Chemical Society Read & Publish Agreement 2022-2024 (Reading list)
subjects Analytical chemistry
Atmosphere
Deuterium - chemistry
Deuterium Exchange Measurement
Hydrogen
Hydrogen - chemistry
Mass spectrometry
Spectrometry, Mass, Electrospray Ionization - methods
Water - chemistry
title Simple Atmospheric Hydrogen/Deuterium Exchange Method for Enumeration of Labile Hydrogens by Electrospray Ionization Mass Spectrometry
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T07%3A07%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simple%20Atmospheric%20Hydrogen/Deuterium%20Exchange%20Method%20for%20Enumeration%20of%20Labile%20Hydrogens%20by%20Electrospray%20Ionization%20Mass%20Spectrometry&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Kostyukevich,%20Yury&rft.date=2013-06-04&rft.volume=85&rft.issue=11&rft.spage=5330&rft.epage=5334&rft.pages=5330-5334&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac4006606&rft_dat=%3Cproquest_cross%3E2990126481%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a376t-3b3587f039cca5a8ad5a9fe4372e0c2fc095bbe48b62b973a132a8200b600f573%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1365656625&rft_id=info:pmid/23647106&rfr_iscdi=true