Determination of Isocitrate Using Immobilized Isocitrate Dehydrogenase in a Flow System and its Application to Analyze the Total Isocitrate Content of Beverages

The quantity of isocitrate was determined using an apparatus containing a reactor with immobilized isocitrate dehydrogenase in a flow line. NADH formed by an enzymatic reaction was fluorometrically detected. The optimal concentration of NAD+ in the carrier was determined. The maximum peak areas due...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Health Science 2005, Vol.51(6), pp.711-714
Main Authors: Mori, Hisakazu, Okamoto, Yukiko, Fujita, Yuko
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c587t-7528441e5f07e9df70cad4a9212d134810921383ba20e1963aeabfae9d961cc63
cites cdi_FETCH-LOGICAL-c587t-7528441e5f07e9df70cad4a9212d134810921383ba20e1963aeabfae9d961cc63
container_end_page 714
container_issue 6
container_start_page 711
container_title Journal of Health Science
container_volume 51
creator Mori, Hisakazu
Okamoto, Yukiko
Fujita, Yuko
description The quantity of isocitrate was determined using an apparatus containing a reactor with immobilized isocitrate dehydrogenase in a flow line. NADH formed by an enzymatic reaction was fluorometrically detected. The optimal concentration of NAD+ in the carrier was determined. The maximum peak areas due to NADH were observed at pH 8.0 when the pH of the carrier consisting of Tris buffer ranged from 6.0 to 8.6. Various buffer types were also examined as carrier mediums at pH 8.0. In contrast to 2-[4-(2-hydroxyethyl)-1-piperazinyl]ethanesulfonic acid (HEPES), piperazine-1,4-bis(2-ethanesulfonic acid) (PIPES) and triethanolamine buffers which afforded comparable peak areas with that of Tris buffer, phosphate buffer showed a reduced peak area. This peak area decreased with an increase in the pH of the phosphate buffer from 6.5 to 8.5, suggesting the inhibitory effect of phosphate dianions upon the binding of adenosine-5′-monophosphate (AMP) to the binding site of the enzyme. When the carrier composed of Tris buffer (0.1 M, pH 8.0) was used, the calibration curve for isocitrate was linear in the range of 0.1-50 μM (r = 1.000). The detection limit (S/N = 3) was 0.07 μM. Relative standard deviations of the peak area at 1 and 10 μM were 4.0% (n = 7) and 2.8% (n = 7), respectively. Thirty samples of isocitrate (2 μM) were analyzed for 1 hr. This method was applied to the analysis of total isocitrate in several beverages. The recovery tests for the isocitrate added to samples indicatied the reliability of the present method.
doi_str_mv 10.1248/jhs.51.711
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1443495612</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3104422861</sourcerecordid><originalsourceid>FETCH-LOGICAL-c587t-7528441e5f07e9df70cad4a9212d134810921383ba20e1963aeabfae9d961cc63</originalsourceid><addsrcrecordid>eNpNkc1u1DAQxyMEEqX00iewxA0pW4_jxMkJLdsPVqrEgfZseZ3JxivHXmwXtH2aPmq9hEIPHo80__nNV1GcA10A4-3FboyLGhYC4E1xAhUXZc2oePvH52UnKHtffIhxRynraAsnxdMlJgyTcSoZ74gfyDp6bVJQCcl9NG5L1tPkN8aaR-xfBy9xPPTBb9GpiMQ4osi19b_Jj0NMOBHlemJSJMv93ho905MnS6fs4RFJGpHc-aTsa-TKu4QuHbv4ir8wqC3Gj8W7QdmIZ3__0-L--upu9a28_X6zXi1vS123IpWiZi3ngPVABXb9IKhWPVcdA9bn2Vug2a3aaqMYReiaSqHaDCpLuwa0bqrT4tPM3Qf_8wFjkjv_EHK3UQLnFe_qBlhWfZ5VOvgYAw5yH8ykwkEClccLyHwBWYPMF8jim1k8YZ9XYL2zxuF_ro5iRGWTZJTWMj-gjaTAJM3ZR8OBiorWXSZ9mUm7mPJS_hVVIRlt8aVoM5tj9ktEjypIdNUzZqCpBQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1443495612</pqid></control><display><type>article</type><title>Determination of Isocitrate Using Immobilized Isocitrate Dehydrogenase in a Flow System and its Application to Analyze the Total Isocitrate Content of Beverages</title><source>Freely Accessible Journals</source><creator>Mori, Hisakazu ; Okamoto, Yukiko ; Fujita, Yuko</creator><creatorcontrib>Mori, Hisakazu ; Okamoto, Yukiko ; Fujita, Yuko ; Kyoritsu College of Pharmacy</creatorcontrib><description>The quantity of isocitrate was determined using an apparatus containing a reactor with immobilized isocitrate dehydrogenase in a flow line. NADH formed by an enzymatic reaction was fluorometrically detected. The optimal concentration of NAD+ in the carrier was determined. The maximum peak areas due to NADH were observed at pH 8.0 when the pH of the carrier consisting of Tris buffer ranged from 6.0 to 8.6. Various buffer types were also examined as carrier mediums at pH 8.0. In contrast to 2-[4-(2-hydroxyethyl)-1-piperazinyl]ethanesulfonic acid (HEPES), piperazine-1,4-bis(2-ethanesulfonic acid) (PIPES) and triethanolamine buffers which afforded comparable peak areas with that of Tris buffer, phosphate buffer showed a reduced peak area. This peak area decreased with an increase in the pH of the phosphate buffer from 6.5 to 8.5, suggesting the inhibitory effect of phosphate dianions upon the binding of adenosine-5′-monophosphate (AMP) to the binding site of the enzyme. When the carrier composed of Tris buffer (0.1 M, pH 8.0) was used, the calibration curve for isocitrate was linear in the range of 0.1-50 μM (r = 1.000). The detection limit (S/N = 3) was 0.07 μM. Relative standard deviations of the peak area at 1 and 10 μM were 4.0% (n = 7) and 2.8% (n = 7), respectively. Thirty samples of isocitrate (2 μM) were analyzed for 1 hr. This method was applied to the analysis of total isocitrate in several beverages. The recovery tests for the isocitrate added to samples indicatied the reliability of the present method.</description><identifier>ISSN: 1344-9702</identifier><identifier>EISSN: 1347-5207</identifier><identifier>DOI: 10.1248/jhs.51.711</identifier><language>eng</language><publisher>Tokyo: The Pharmaceutical Society of Japan</publisher><subject>beverage ; flow injection analysis ; immobilized enzyme ; isocitrate ; isocitrate dehydrogenase</subject><ispartof>Journal of Health Science, 2005, Vol.51(6), pp.711-714</ispartof><rights>2005 by The Pharmaceutical Society of Japan</rights><rights>Copyright Japan Science and Technology Agency 2005</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c587t-7528441e5f07e9df70cad4a9212d134810921383ba20e1963aeabfae9d961cc63</citedby><cites>FETCH-LOGICAL-c587t-7528441e5f07e9df70cad4a9212d134810921383ba20e1963aeabfae9d961cc63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4023,27922,27923,27924</link.rule.ids></links><search><creatorcontrib>Mori, Hisakazu</creatorcontrib><creatorcontrib>Okamoto, Yukiko</creatorcontrib><creatorcontrib>Fujita, Yuko</creatorcontrib><creatorcontrib>Kyoritsu College of Pharmacy</creatorcontrib><title>Determination of Isocitrate Using Immobilized Isocitrate Dehydrogenase in a Flow System and its Application to Analyze the Total Isocitrate Content of Beverages</title><title>Journal of Health Science</title><description>The quantity of isocitrate was determined using an apparatus containing a reactor with immobilized isocitrate dehydrogenase in a flow line. NADH formed by an enzymatic reaction was fluorometrically detected. The optimal concentration of NAD+ in the carrier was determined. The maximum peak areas due to NADH were observed at pH 8.0 when the pH of the carrier consisting of Tris buffer ranged from 6.0 to 8.6. Various buffer types were also examined as carrier mediums at pH 8.0. In contrast to 2-[4-(2-hydroxyethyl)-1-piperazinyl]ethanesulfonic acid (HEPES), piperazine-1,4-bis(2-ethanesulfonic acid) (PIPES) and triethanolamine buffers which afforded comparable peak areas with that of Tris buffer, phosphate buffer showed a reduced peak area. This peak area decreased with an increase in the pH of the phosphate buffer from 6.5 to 8.5, suggesting the inhibitory effect of phosphate dianions upon the binding of adenosine-5′-monophosphate (AMP) to the binding site of the enzyme. When the carrier composed of Tris buffer (0.1 M, pH 8.0) was used, the calibration curve for isocitrate was linear in the range of 0.1-50 μM (r = 1.000). The detection limit (S/N = 3) was 0.07 μM. Relative standard deviations of the peak area at 1 and 10 μM were 4.0% (n = 7) and 2.8% (n = 7), respectively. Thirty samples of isocitrate (2 μM) were analyzed for 1 hr. This method was applied to the analysis of total isocitrate in several beverages. The recovery tests for the isocitrate added to samples indicatied the reliability of the present method.</description><subject>beverage</subject><subject>flow injection analysis</subject><subject>immobilized enzyme</subject><subject>isocitrate</subject><subject>isocitrate dehydrogenase</subject><issn>1344-9702</issn><issn>1347-5207</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNpNkc1u1DAQxyMEEqX00iewxA0pW4_jxMkJLdsPVqrEgfZseZ3JxivHXmwXtH2aPmq9hEIPHo80__nNV1GcA10A4-3FboyLGhYC4E1xAhUXZc2oePvH52UnKHtffIhxRynraAsnxdMlJgyTcSoZ74gfyDp6bVJQCcl9NG5L1tPkN8aaR-xfBy9xPPTBb9GpiMQ4osi19b_Jj0NMOBHlemJSJMv93ho905MnS6fs4RFJGpHc-aTsa-TKu4QuHbv4ir8wqC3Gj8W7QdmIZ3__0-L--upu9a28_X6zXi1vS123IpWiZi3ngPVABXb9IKhWPVcdA9bn2Vug2a3aaqMYReiaSqHaDCpLuwa0bqrT4tPM3Qf_8wFjkjv_EHK3UQLnFe_qBlhWfZ5VOvgYAw5yH8ykwkEClccLyHwBWYPMF8jim1k8YZ9XYL2zxuF_ro5iRGWTZJTWMj-gjaTAJM3ZR8OBiorWXSZ9mUm7mPJS_hVVIRlt8aVoM5tj9ktEjypIdNUzZqCpBQ</recordid><startdate>2005</startdate><enddate>2005</enddate><creator>Mori, Hisakazu</creator><creator>Okamoto, Yukiko</creator><creator>Fujita, Yuko</creator><general>The Pharmaceutical Society of Japan</general><general>Pharmaceutical Society of Japan</general><general>Pharmaceutical Society of Japan, Nihon Yakugakkai</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2005</creationdate><title>Determination of Isocitrate Using Immobilized Isocitrate Dehydrogenase in a Flow System and its Application to Analyze the Total Isocitrate Content of Beverages</title><author>Mori, Hisakazu ; Okamoto, Yukiko ; Fujita, Yuko</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c587t-7528441e5f07e9df70cad4a9212d134810921383ba20e1963aeabfae9d961cc63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>beverage</topic><topic>flow injection analysis</topic><topic>immobilized enzyme</topic><topic>isocitrate</topic><topic>isocitrate dehydrogenase</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mori, Hisakazu</creatorcontrib><creatorcontrib>Okamoto, Yukiko</creatorcontrib><creatorcontrib>Fujita, Yuko</creatorcontrib><creatorcontrib>Kyoritsu College of Pharmacy</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of Health Science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mori, Hisakazu</au><au>Okamoto, Yukiko</au><au>Fujita, Yuko</au><aucorp>Kyoritsu College of Pharmacy</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of Isocitrate Using Immobilized Isocitrate Dehydrogenase in a Flow System and its Application to Analyze the Total Isocitrate Content of Beverages</atitle><jtitle>Journal of Health Science</jtitle><date>2005</date><risdate>2005</risdate><volume>51</volume><issue>6</issue><spage>711</spage><epage>714</epage><pages>711-714</pages><issn>1344-9702</issn><eissn>1347-5207</eissn><abstract>The quantity of isocitrate was determined using an apparatus containing a reactor with immobilized isocitrate dehydrogenase in a flow line. NADH formed by an enzymatic reaction was fluorometrically detected. The optimal concentration of NAD+ in the carrier was determined. The maximum peak areas due to NADH were observed at pH 8.0 when the pH of the carrier consisting of Tris buffer ranged from 6.0 to 8.6. Various buffer types were also examined as carrier mediums at pH 8.0. In contrast to 2-[4-(2-hydroxyethyl)-1-piperazinyl]ethanesulfonic acid (HEPES), piperazine-1,4-bis(2-ethanesulfonic acid) (PIPES) and triethanolamine buffers which afforded comparable peak areas with that of Tris buffer, phosphate buffer showed a reduced peak area. This peak area decreased with an increase in the pH of the phosphate buffer from 6.5 to 8.5, suggesting the inhibitory effect of phosphate dianions upon the binding of adenosine-5′-monophosphate (AMP) to the binding site of the enzyme. When the carrier composed of Tris buffer (0.1 M, pH 8.0) was used, the calibration curve for isocitrate was linear in the range of 0.1-50 μM (r = 1.000). The detection limit (S/N = 3) was 0.07 μM. Relative standard deviations of the peak area at 1 and 10 μM were 4.0% (n = 7) and 2.8% (n = 7), respectively. Thirty samples of isocitrate (2 μM) were analyzed for 1 hr. This method was applied to the analysis of total isocitrate in several beverages. The recovery tests for the isocitrate added to samples indicatied the reliability of the present method.</abstract><cop>Tokyo</cop><pub>The Pharmaceutical Society of Japan</pub><doi>10.1248/jhs.51.711</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1344-9702
ispartof Journal of Health Science, 2005, Vol.51(6), pp.711-714
issn 1344-9702
1347-5207
language eng
recordid cdi_proquest_journals_1443495612
source Freely Accessible Journals
subjects beverage
flow injection analysis
immobilized enzyme
isocitrate
isocitrate dehydrogenase
title Determination of Isocitrate Using Immobilized Isocitrate Dehydrogenase in a Flow System and its Application to Analyze the Total Isocitrate Content of Beverages
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T23%3A37%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20Isocitrate%20Using%20Immobilized%20Isocitrate%20Dehydrogenase%20in%20a%20Flow%20System%20and%20its%20Application%20to%20Analyze%20the%20Total%20Isocitrate%20Content%20of%20Beverages&rft.jtitle=Journal%20of%20Health%20Science&rft.au=Mori,%20Hisakazu&rft.aucorp=Kyoritsu%20College%20of%20Pharmacy&rft.date=2005&rft.volume=51&rft.issue=6&rft.spage=711&rft.epage=714&rft.pages=711-714&rft.issn=1344-9702&rft.eissn=1347-5207&rft_id=info:doi/10.1248/jhs.51.711&rft_dat=%3Cproquest_cross%3E3104422861%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c587t-7528441e5f07e9df70cad4a9212d134810921383ba20e1963aeabfae9d961cc63%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1443495612&rft_id=info:pmid/&rfr_iscdi=true