Loading…

Amperometric Glucose Biosensor for an Undiluted Whole-Blood Analysis

The design of an enzymatic biosensor based on the use of immobilized glucose oxidase is described for the determination of glucose in blood serum and undiluted whole blood. Measurements in whole blood with RSD=0.3% are possible due to the use of an outer polypropylene membrane wetted with a mixture...

Full description

Saved in:
Bibliographic Details
Published in:Analytical Sciences 1994/06/10, Vol.10(3), pp.423-428
Main Authors: MATUSZEWSKI, W., TROJANOWICZ, M., LEWENSTAM, A., MOSCZYNSKA, A., LANGE-MOROZ, E.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c483t-569840187bd62756152d4dda97ace7937b1f92453f4ba3ae63fd6316ad8bb2813
cites cdi_FETCH-LOGICAL-c483t-569840187bd62756152d4dda97ace7937b1f92453f4ba3ae63fd6316ad8bb2813
container_end_page 428
container_issue 3
container_start_page 423
container_title Analytical Sciences
container_volume 10
creator MATUSZEWSKI, W.
TROJANOWICZ, M.
LEWENSTAM, A.
MOSCZYNSKA, A.
LANGE-MOROZ, E.
description The design of an enzymatic biosensor based on the use of immobilized glucose oxidase is described for the determination of glucose in blood serum and undiluted whole blood. Measurements in whole blood with RSD=0.3% are possible due to the use of an outer polypropylene membrane wetted with a mixture of various polyoxyethylene ethers (Triton X-100).
doi_str_mv 10.2116/analsci.10.423
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1448514874</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3117788281</sourcerecordid><originalsourceid>FETCH-LOGICAL-c483t-569840187bd62756152d4dda97ace7937b1f92453f4ba3ae63fd6316ad8bb2813</originalsourceid><addsrcrecordid>eNo9kL1PwzAQxS0EEqWwMkeCNcVfcZyxLaUgVWKhYowutkNdpXGxk6H_PY5SOtydTv7de_JD6JHgGSVEvEALTVB2FndO2RWaEMZlSikX12iCC4JTwTi-RXch7DEmVFI6Qa_zw9F4dzCdtypZN71ywSQLG3sbnE_qWNAm21bbpu-MTr53rjHponFOJ_PoeAo23KObOnqbh_Ocou3b6mv5nm4-1x_L-SZVXLIuzUQhOSYyr7SgeSZIRjXXGooclMkLllekLijPWM0rYGAEq7VgRICWVUUlYVP0NOoevfvtTejKvev98O2ScC4zwmXOIzUbKeVdCN7U5dHbA_hTSXA5JFWekxr2mFQ8eD7LQlDQ1B5aZcPlirGYFssith6xfejgx1zewXdWNeZflRQyG5TZ2KLBhVA78KVp2R9X84KG</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1448514874</pqid></control><display><type>article</type><title>Amperometric Glucose Biosensor for an Undiluted Whole-Blood Analysis</title><source>J-STAGE (Japan Science &amp; Technology Information Aggregator, Electronic) Freely Available Titles - English</source><creator>MATUSZEWSKI, W. ; TROJANOWICZ, M. ; LEWENSTAM, A. ; MOSCZYNSKA, A. ; LANGE-MOROZ, E.</creator><creatorcontrib>MATUSZEWSKI, W. ; TROJANOWICZ, M. ; LEWENSTAM, A. ; MOSCZYNSKA, A. ; LANGE-MOROZ, E.</creatorcontrib><description>The design of an enzymatic biosensor based on the use of immobilized glucose oxidase is described for the determination of glucose in blood serum and undiluted whole blood. Measurements in whole blood with RSD=0.3% are possible due to the use of an outer polypropylene membrane wetted with a mixture of various polyoxyethylene ethers (Triton X-100).</description><identifier>ISSN: 0910-6340</identifier><identifier>EISSN: 1348-2246</identifier><identifier>DOI: 10.2116/analsci.10.423</identifier><identifier>CODEN: ANSCEN</identifier><language>eng</language><publisher>Tokyo: The Japan Society for Analytical Chemistry</publisher><subject>amperometric Biosensor ; Biological and medical sciences ; Biosensors ; Biotechnology ; Fundamental and applied biological sciences. Psychology ; Glucose ; Methods. Procedures. Technologies ; Various methods and equipments ; whole-blood analysis</subject><ispartof>Analytical Sciences, 1994/06/10, Vol.10(3), pp.423-428</ispartof><rights>The Japan Society for Analytical Chemistry</rights><rights>1995 INIST-CNRS</rights><rights>Copyright Japan Science and Technology Agency 1994</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c483t-569840187bd62756152d4dda97ace7937b1f92453f4ba3ae63fd6316ad8bb2813</citedby><cites>FETCH-LOGICAL-c483t-569840187bd62756152d4dda97ace7937b1f92453f4ba3ae63fd6316ad8bb2813</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,1877,4011,27905,27906,27907</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=3300135$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>MATUSZEWSKI, W.</creatorcontrib><creatorcontrib>TROJANOWICZ, M.</creatorcontrib><creatorcontrib>LEWENSTAM, A.</creatorcontrib><creatorcontrib>MOSCZYNSKA, A.</creatorcontrib><creatorcontrib>LANGE-MOROZ, E.</creatorcontrib><title>Amperometric Glucose Biosensor for an Undiluted Whole-Blood Analysis</title><title>Analytical Sciences</title><description>The design of an enzymatic biosensor based on the use of immobilized glucose oxidase is described for the determination of glucose in blood serum and undiluted whole blood. Measurements in whole blood with RSD=0.3% are possible due to the use of an outer polypropylene membrane wetted with a mixture of various polyoxyethylene ethers (Triton X-100).</description><subject>amperometric Biosensor</subject><subject>Biological and medical sciences</subject><subject>Biosensors</subject><subject>Biotechnology</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Glucose</subject><subject>Methods. Procedures. Technologies</subject><subject>Various methods and equipments</subject><subject>whole-blood analysis</subject><issn>0910-6340</issn><issn>1348-2246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><recordid>eNo9kL1PwzAQxS0EEqWwMkeCNcVfcZyxLaUgVWKhYowutkNdpXGxk6H_PY5SOtydTv7de_JD6JHgGSVEvEALTVB2FndO2RWaEMZlSikX12iCC4JTwTi-RXch7DEmVFI6Qa_zw9F4dzCdtypZN71ywSQLG3sbnE_qWNAm21bbpu-MTr53rjHponFOJ_PoeAo23KObOnqbh_Ocou3b6mv5nm4-1x_L-SZVXLIuzUQhOSYyr7SgeSZIRjXXGooclMkLllekLijPWM0rYGAEq7VgRICWVUUlYVP0NOoevfvtTejKvev98O2ScC4zwmXOIzUbKeVdCN7U5dHbA_hTSXA5JFWekxr2mFQ8eD7LQlDQ1B5aZcPlirGYFssith6xfejgx1zewXdWNeZflRQyG5TZ2KLBhVA78KVp2R9X84KG</recordid><startdate>1994</startdate><enddate>1994</enddate><creator>MATUSZEWSKI, W.</creator><creator>TROJANOWICZ, M.</creator><creator>LEWENSTAM, A.</creator><creator>MOSCZYNSKA, A.</creator><creator>LANGE-MOROZ, E.</creator><general>The Japan Society for Analytical Chemistry</general><general>Japan Society for Analytical Chemistry</general><general>Japan Science and Technology Agency</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SE</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>H8G</scope><scope>JG9</scope><scope>L7M</scope><scope>P64</scope></search><sort><creationdate>1994</creationdate><title>Amperometric Glucose Biosensor for an Undiluted Whole-Blood Analysis</title><author>MATUSZEWSKI, W. ; TROJANOWICZ, M. ; LEWENSTAM, A. ; MOSCZYNSKA, A. ; LANGE-MOROZ, E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c483t-569840187bd62756152d4dda97ace7937b1f92453f4ba3ae63fd6316ad8bb2813</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>amperometric Biosensor</topic><topic>Biological and medical sciences</topic><topic>Biosensors</topic><topic>Biotechnology</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Glucose</topic><topic>Methods. Procedures. Technologies</topic><topic>Various methods and equipments</topic><topic>whole-blood analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>MATUSZEWSKI, W.</creatorcontrib><creatorcontrib>TROJANOWICZ, M.</creatorcontrib><creatorcontrib>LEWENSTAM, A.</creatorcontrib><creatorcontrib>MOSCZYNSKA, A.</creatorcontrib><creatorcontrib>LANGE-MOROZ, E.</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Copper Technical Reference Library</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Analytical Sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MATUSZEWSKI, W.</au><au>TROJANOWICZ, M.</au><au>LEWENSTAM, A.</au><au>MOSCZYNSKA, A.</au><au>LANGE-MOROZ, E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Amperometric Glucose Biosensor for an Undiluted Whole-Blood Analysis</atitle><jtitle>Analytical Sciences</jtitle><date>1994</date><risdate>1994</risdate><volume>10</volume><issue>3</issue><spage>423</spage><epage>428</epage><pages>423-428</pages><issn>0910-6340</issn><eissn>1348-2246</eissn><coden>ANSCEN</coden><abstract>The design of an enzymatic biosensor based on the use of immobilized glucose oxidase is described for the determination of glucose in blood serum and undiluted whole blood. Measurements in whole blood with RSD=0.3% are possible due to the use of an outer polypropylene membrane wetted with a mixture of various polyoxyethylene ethers (Triton X-100).</abstract><cop>Tokyo</cop><pub>The Japan Society for Analytical Chemistry</pub><doi>10.2116/analsci.10.423</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0910-6340
ispartof Analytical Sciences, 1994/06/10, Vol.10(3), pp.423-428
issn 0910-6340
1348-2246
language eng
recordid cdi_proquest_journals_1448514874
source J-STAGE (Japan Science & Technology Information Aggregator, Electronic) Freely Available Titles - English
subjects amperometric Biosensor
Biological and medical sciences
Biosensors
Biotechnology
Fundamental and applied biological sciences. Psychology
Glucose
Methods. Procedures. Technologies
Various methods and equipments
whole-blood analysis
title Amperometric Glucose Biosensor for an Undiluted Whole-Blood Analysis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T08%3A07%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Amperometric%20Glucose%20Biosensor%20for%20an%20Undiluted%20Whole-Blood%20Analysis&rft.jtitle=Analytical%20Sciences&rft.au=MATUSZEWSKI,%20W.&rft.date=1994&rft.volume=10&rft.issue=3&rft.spage=423&rft.epage=428&rft.pages=423-428&rft.issn=0910-6340&rft.eissn=1348-2246&rft.coden=ANSCEN&rft_id=info:doi/10.2116/analsci.10.423&rft_dat=%3Cproquest_cross%3E3117788281%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c483t-569840187bd62756152d4dda97ace7937b1f92453f4ba3ae63fd6316ad8bb2813%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1448514874&rft_id=info:pmid/&rfr_iscdi=true