Loading…
The new method of initial calibration with the wheel force transducer
Purpose – One of the major shortcomings in the data process of the traditional wheel force transducers (WFTs) is the theoretical errors of initial value determination. A new method to identify the initial values of the WFT for the solution of this problem is proposed in this paper. The paper aims to...
Saved in:
Published in: | Sensor review 2014-01, Vol.34 (1), p.98-109 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Purpose
– One of the major shortcomings in the data process of the traditional wheel force transducers (WFTs) is the theoretical errors of initial value determination. A new method to identify the initial values of the WFT for the solution of this problem is proposed in this paper. The paper aims to discuss these issues.
Design/methodology/approach
– With this method, the initial values can be obtained by equations which are established based on multiple stops on horizontal road.
Findings
– The calibration and contrast tests on the MTS calibration platform illustrate the better performance with the new method. Moreover, the real vehicle test confirms the effectiveness in practice.
Originality/value
– The test results show that the new method of initial calibration has an advanced performance compared to the traditional one. In addition, it is effective in the brake test with a real vehicle. |
---|---|
ISSN: | 0260-2288 1758-6828 |
DOI: | 10.1108/SR-12-2012-734 |