Loading…

Accuracy of computed tomography detection of superior canal dehiscence

Citation: Sequeira SM, Whiting BR, Shimony JS, Vo KD, Hullar TE. Accuracy of computed tomography detection of superior canal dehiscence. Cochrane Database of Systematic Reviews 2011, Issue 9. pp. 1500–1505. DOI: 10.1097/MAO.0b013e318238280c. Hypothesis  High‐resolution temporal bone computed tomogra...

Full description

Saved in:
Bibliographic Details
Published in:Clinical otolaryngology 2012-08, Vol.37 (4), p.297-297
Main Authors: Sequeira, S.M., Whiting, B.R., Shimony, J.S., Vo, K.D., Hullar, T.E.
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Citation: Sequeira SM, Whiting BR, Shimony JS, Vo KD, Hullar TE. Accuracy of computed tomography detection of superior canal dehiscence. Cochrane Database of Systematic Reviews 2011, Issue 9. pp. 1500–1505. DOI: 10.1097/MAO.0b013e318238280c. Hypothesis  High‐resolution temporal bone computed tomography (CT) may erroneously demonstrate a superior semicircular canal dehiscence (SSCD) where none exists and inaccurately display the size of a dehiscence. Background  CT is an integral component of the diagnosis of SSCD. The prevalence of dehiscence as measured on computed tomographic scan is approximately eightfold higher than that on histologic studies, suggesting that CT may have a relatively low specificity for identifying canal dehiscence. This, in turn, can lead to an inappropriate diagnosis and treatment plan. Methods  We quantified the accuracy of CT in identifying a dehiscence of the superior semicircular canal in a cadaver model using microCT as a gold standard. The superior canals of 11 cadaver heads were blue lined. Twelve of the 22 ears were further drilled to create fenestrations of varying sizes. Heads were imaged using medical CT, followed by microCT scans of the temporal bones at 18‐μm resolution. Diagnosis of dehiscence and measurements of dehiscence size were performed on clinical CT and compared with that of microCT. Results  Clinical CT identified 7 of 8 intact canals as dehiscent and tended to overestimate the size of smaller fenestrations, particularly those surrounded by thin bone. Conclusion  These findings confirm that medical CT cannot be used as the exclusive gold standard for SSCD and that, particularly for small dehiscences on CT, clinical symptoms must be clearly indicative of a dehiscence before surgical treatment is undertaken. Preoperative counselling for small dehiscences may need to include the possibility that no dehiscence may be found despite radiologic evidence for it.
ISSN:1749-4478
1749-4486
DOI:10.1111/j.1749-4486.2012.02522.x