GW25-e4485 The analyses of incidence of failure and relate factors in patients with retrograde wire for the treatment of chronic coronary artery occlusion
Methods The data of 170 CTO patients undergoing retrograde PCI for a CTO from August 2004 to October 2013.170 cases with chronic coronary artery occlusion underwent transcutaneous coronary artery intervention (PCI) therapy by retrograde wire technique were enrolled in this study (male: 97, mean age:...
Saved in:
Published in: | Journal of the American College of Cardiology 2014-10, Vol.64 (16), p.C151-C151 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Methods The data of 170 CTO patients undergoing retrograde PCI for a CTO from August 2004 to October 2013.170 cases with chronic coronary artery occlusion underwent transcutaneous coronary artery intervention (PCI) therapy by retrograde wire technique were enrolled in this study (male: 97, mean age: 60.6±11.3 years).Failure is defined as wire is unable to pass through the occlusion of the target - artery or retrograde wire is unable to find the collateral circulation of miraclechannel. |
---|---|