Loading…
PP-171 The Use of Low Molecular Weight Heparin During Pregnancy in Patients with Mechanical Heart Valves Carries Potential Risk for Valve Thrombosis: A Report of Three Cases
Transthoracic and transesophageal echocardiography (TTE and TEE) depicted 6 mm fibrillar thrombus in the aortic prosthetic valve and thrombi in the mitral prosthetic valve (Figure). [...]in the absence of anti-Xa monitoring, pregnants with MHV should not be treated with a fixed dose of LMWH, as such...
Saved in:
Published in: | The American journal of cardiology 2015-03, Vol.115, p.S172-S172 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Transthoracic and transesophageal echocardiography (TTE and TEE) depicted 6 mm fibrillar thrombus in the aortic prosthetic valve and thrombi in the mitral prosthetic valve (Figure). [...]in the absence of anti-Xa monitoring, pregnants with MHV should not be treated with a fixed dose of LMWH, as such treatment likely results in ineffective anticoagulation. |
---|---|
ISSN: | 0002-9149 1879-1913 |
DOI: | 10.1016/j.amjcard.2015.01.528 |