Development And Investigation Of An Optical Power Meter Front End
Circuit of the classical transimpedance amplifier (TIA) is revised and improved circuit is developed. Analytical solutions for the classical and improved circuits are derived. Both circuits were built and their parameters were measured. An experiment results showed that improved TIA achieves 4.5 dB...
Saved in:
Published in: | Science future of Lithuania 2015-05, Vol.7 (3), p.330 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | eng ; lit |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Circuit of the classical transimpedance amplifier (TIA) is revised and improved circuit is developed. Analytical solutions for the classical and improved circuits are derived. Both circuits were built and their parameters were measured. An experiment results showed that improved TIA achieves 4.5 dB greater dynamic rage than the classical TIA at +50 °C and 12 dB greater at -10 °C. Article in: Lithuanian Article published: 2015-07-13 |
---|---|
ISSN: | 2029-2341 2029-2252 |
DOI: | 10.3846/mla.2015.794 |