Loading…
Output-Feedback Nonlinear Adaptive Control of Single-Phase Half-Bridge Ups Systems
We consider the problem of controlling single‐phase half‐bridge power converters in UPS systems operating in the presence of changing load. The control objective is twofold: (i) ensuring a satisfactory power factor correction (PFC) at the grid–UPS connection; (ii) guaranteeing a tight regulation of...
Saved in:
Published in: | Asian journal of control 2016-11, Vol.18 (6), p.1995-2009 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3353-fe0e7e016837739fcaae2fa5c81d4f463b06ad6a5cad7f0d78f8d8deca9b734c3 |
---|---|
cites | cdi_FETCH-LOGICAL-c3353-fe0e7e016837739fcaae2fa5c81d4f463b06ad6a5cad7f0d78f8d8deca9b734c3 |
container_end_page | 2009 |
container_issue | 6 |
container_start_page | 1995 |
container_title | Asian journal of control |
container_volume | 18 |
creator | Kissaoui, M. Abouloifa, A. Abouelmahjoub, Y. Chaoui, F. Z. Giri, F. |
description | We consider the problem of controlling single‐phase half‐bridge power converters in UPS systems operating in the presence of changing load. The control objective is twofold: (i) ensuring a satisfactory power factor correction (PFC) at the grid–UPS connection; (ii) guaranteeing a tight regulation of the DC bus voltage and the half‐bridge inverter output voltage despite changes in load. The considered control problem entails several difficulties including: (i) the high dimension and strong nonlinearity of the system; (ii) the numerous state variables that are inaccessible to measurements; (iii) the uncertainty that prevails on some system parameters. The problem is dealt with using a multi‐loop nonlinear adaptive control system that makes use of the backstepping design technique. The inner loop ensures the PFC objective and involves an adaptive observer estimating the grid voltage and impedance parameters. The intermediary loop regulates the inverter output voltage to its reference, which is a sinusoidal wave, and it also contains an observer estimating the current in the inverter coil. The outer loop regulates the DC bus voltage up to small size ripples. The controller performances are formally analyzed using system averaging theory. |
doi_str_mv | 10.1002/asjc.1293 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1844748721</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>4265705291</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3353-fe0e7e016837739fcaae2fa5c81d4f463b06ad6a5cad7f0d78f8d8deca9b734c3</originalsourceid><addsrcrecordid>eNp1kFFPwjAQxxejiYg--A2W-ORDoV23tntEIiAgGCcx8aUp6xUHc5vtUPn2jkB88-kul9__LvfzvGuCOwTjoKvcOu2QIKYnXovENEQMx_S06SNGkGBBdO5dOLfGmBEqopb3PN_W1bZGAwC9VOnGn5VFnhWgrN_TqqqzL_D7ZVHbMvdL4ydZscoBPb0rB_5I5Qbd2UyvwF9Uzk92roYPd-mdGZU7uDrWtrcY3L_0R2g6Hz70e1OUUhpRZAADB0yYoJzT2KRKQWBUlAqiQxMyusRMadYMlOYGay6M0EJDquIlp2FK297NYW9ly88tuFquy60tmpOSiDDkoeABaajbA5Xa0jkLRlY2-1B2JwmWe2Vyr0zulTVs98B-Zzns_gdlLxn3jwl0SGTN6z9_CWU3knHKI_k6G8rxYzB5CyeRTOgvyHJ9XQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1844748721</pqid></control><display><type>article</type><title>Output-Feedback Nonlinear Adaptive Control of Single-Phase Half-Bridge Ups Systems</title><source>Wiley</source><creator>Kissaoui, M. ; Abouloifa, A. ; Abouelmahjoub, Y. ; Chaoui, F. Z. ; Giri, F.</creator><creatorcontrib>Kissaoui, M. ; Abouloifa, A. ; Abouelmahjoub, Y. ; Chaoui, F. Z. ; Giri, F.</creatorcontrib><description>We consider the problem of controlling single‐phase half‐bridge power converters in UPS systems operating in the presence of changing load. The control objective is twofold: (i) ensuring a satisfactory power factor correction (PFC) at the grid–UPS connection; (ii) guaranteeing a tight regulation of the DC bus voltage and the half‐bridge inverter output voltage despite changes in load. The considered control problem entails several difficulties including: (i) the high dimension and strong nonlinearity of the system; (ii) the numerous state variables that are inaccessible to measurements; (iii) the uncertainty that prevails on some system parameters. The problem is dealt with using a multi‐loop nonlinear adaptive control system that makes use of the backstepping design technique. The inner loop ensures the PFC objective and involves an adaptive observer estimating the grid voltage and impedance parameters. The intermediary loop regulates the inverter output voltage to its reference, which is a sinusoidal wave, and it also contains an observer estimating the current in the inverter coil. The outer loop regulates the DC bus voltage up to small size ripples. The controller performances are formally analyzed using system averaging theory.</description><identifier>ISSN: 1561-8625</identifier><identifier>EISSN: 1934-6093</identifier><identifier>DOI: 10.1002/asjc.1293</identifier><language>eng</language><publisher>Hoboken: Blackwell Publishing Ltd</publisher><subject>Adaptive observer ; Control systems ; Motors ; nonlinear control ; power factor correction ; single-phase half-bridge ups systems ; stability analysis ; Uninterruptible power supply</subject><ispartof>Asian journal of control, 2016-11, Vol.18 (6), p.1995-2009</ispartof><rights>2016 Chinese Automatic Control Society and John Wiley & Sons Australia, Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3353-fe0e7e016837739fcaae2fa5c81d4f463b06ad6a5cad7f0d78f8d8deca9b734c3</citedby><cites>FETCH-LOGICAL-c3353-fe0e7e016837739fcaae2fa5c81d4f463b06ad6a5cad7f0d78f8d8deca9b734c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Kissaoui, M.</creatorcontrib><creatorcontrib>Abouloifa, A.</creatorcontrib><creatorcontrib>Abouelmahjoub, Y.</creatorcontrib><creatorcontrib>Chaoui, F. Z.</creatorcontrib><creatorcontrib>Giri, F.</creatorcontrib><title>Output-Feedback Nonlinear Adaptive Control of Single-Phase Half-Bridge Ups Systems</title><title>Asian journal of control</title><addtitle>Asian Journal of Control</addtitle><description>We consider the problem of controlling single‐phase half‐bridge power converters in UPS systems operating in the presence of changing load. The control objective is twofold: (i) ensuring a satisfactory power factor correction (PFC) at the grid–UPS connection; (ii) guaranteeing a tight regulation of the DC bus voltage and the half‐bridge inverter output voltage despite changes in load. The considered control problem entails several difficulties including: (i) the high dimension and strong nonlinearity of the system; (ii) the numerous state variables that are inaccessible to measurements; (iii) the uncertainty that prevails on some system parameters. The problem is dealt with using a multi‐loop nonlinear adaptive control system that makes use of the backstepping design technique. The inner loop ensures the PFC objective and involves an adaptive observer estimating the grid voltage and impedance parameters. The intermediary loop regulates the inverter output voltage to its reference, which is a sinusoidal wave, and it also contains an observer estimating the current in the inverter coil. The outer loop regulates the DC bus voltage up to small size ripples. The controller performances are formally analyzed using system averaging theory.</description><subject>Adaptive observer</subject><subject>Control systems</subject><subject>Motors</subject><subject>nonlinear control</subject><subject>power factor correction</subject><subject>single-phase half-bridge ups systems</subject><subject>stability analysis</subject><subject>Uninterruptible power supply</subject><issn>1561-8625</issn><issn>1934-6093</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNp1kFFPwjAQxxejiYg--A2W-ORDoV23tntEIiAgGCcx8aUp6xUHc5vtUPn2jkB88-kul9__LvfzvGuCOwTjoKvcOu2QIKYnXovENEQMx_S06SNGkGBBdO5dOLfGmBEqopb3PN_W1bZGAwC9VOnGn5VFnhWgrN_TqqqzL_D7ZVHbMvdL4ydZscoBPb0rB_5I5Qbd2UyvwF9Uzk92roYPd-mdGZU7uDrWtrcY3L_0R2g6Hz70e1OUUhpRZAADB0yYoJzT2KRKQWBUlAqiQxMyusRMadYMlOYGay6M0EJDquIlp2FK297NYW9ly88tuFquy60tmpOSiDDkoeABaajbA5Xa0jkLRlY2-1B2JwmWe2Vyr0zulTVs98B-Zzns_gdlLxn3jwl0SGTN6z9_CWU3knHKI_k6G8rxYzB5CyeRTOgvyHJ9XQ</recordid><startdate>201611</startdate><enddate>201611</enddate><creator>Kissaoui, M.</creator><creator>Abouloifa, A.</creator><creator>Abouelmahjoub, Y.</creator><creator>Chaoui, F. Z.</creator><creator>Giri, F.</creator><general>Blackwell Publishing Ltd</general><general>Wiley Subscription Services, Inc</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>JQ2</scope></search><sort><creationdate>201611</creationdate><title>Output-Feedback Nonlinear Adaptive Control of Single-Phase Half-Bridge Ups Systems</title><author>Kissaoui, M. ; Abouloifa, A. ; Abouelmahjoub, Y. ; Chaoui, F. Z. ; Giri, F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3353-fe0e7e016837739fcaae2fa5c81d4f463b06ad6a5cad7f0d78f8d8deca9b734c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Adaptive observer</topic><topic>Control systems</topic><topic>Motors</topic><topic>nonlinear control</topic><topic>power factor correction</topic><topic>single-phase half-bridge ups systems</topic><topic>stability analysis</topic><topic>Uninterruptible power supply</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kissaoui, M.</creatorcontrib><creatorcontrib>Abouloifa, A.</creatorcontrib><creatorcontrib>Abouelmahjoub, Y.</creatorcontrib><creatorcontrib>Chaoui, F. Z.</creatorcontrib><creatorcontrib>Giri, F.</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>ProQuest Computer Science Collection</collection><jtitle>Asian journal of control</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kissaoui, M.</au><au>Abouloifa, A.</au><au>Abouelmahjoub, Y.</au><au>Chaoui, F. Z.</au><au>Giri, F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Output-Feedback Nonlinear Adaptive Control of Single-Phase Half-Bridge Ups Systems</atitle><jtitle>Asian journal of control</jtitle><addtitle>Asian Journal of Control</addtitle><date>2016-11</date><risdate>2016</risdate><volume>18</volume><issue>6</issue><spage>1995</spage><epage>2009</epage><pages>1995-2009</pages><issn>1561-8625</issn><eissn>1934-6093</eissn><abstract>We consider the problem of controlling single‐phase half‐bridge power converters in UPS systems operating in the presence of changing load. The control objective is twofold: (i) ensuring a satisfactory power factor correction (PFC) at the grid–UPS connection; (ii) guaranteeing a tight regulation of the DC bus voltage and the half‐bridge inverter output voltage despite changes in load. The considered control problem entails several difficulties including: (i) the high dimension and strong nonlinearity of the system; (ii) the numerous state variables that are inaccessible to measurements; (iii) the uncertainty that prevails on some system parameters. The problem is dealt with using a multi‐loop nonlinear adaptive control system that makes use of the backstepping design technique. The inner loop ensures the PFC objective and involves an adaptive observer estimating the grid voltage and impedance parameters. The intermediary loop regulates the inverter output voltage to its reference, which is a sinusoidal wave, and it also contains an observer estimating the current in the inverter coil. The outer loop regulates the DC bus voltage up to small size ripples. The controller performances are formally analyzed using system averaging theory.</abstract><cop>Hoboken</cop><pub>Blackwell Publishing Ltd</pub><doi>10.1002/asjc.1293</doi><tpages>15</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1561-8625 |
ispartof | Asian journal of control, 2016-11, Vol.18 (6), p.1995-2009 |
issn | 1561-8625 1934-6093 |
language | eng |
recordid | cdi_proquest_journals_1844748721 |
source | Wiley |
subjects | Adaptive observer Control systems Motors nonlinear control power factor correction single-phase half-bridge ups systems stability analysis Uninterruptible power supply |
title | Output-Feedback Nonlinear Adaptive Control of Single-Phase Half-Bridge Ups Systems |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T21%3A10%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Output-Feedback%20Nonlinear%20Adaptive%20Control%20of%20Single-Phase%20Half-Bridge%20Ups%20Systems&rft.jtitle=Asian%20journal%20of%20control&rft.au=Kissaoui,%20M.&rft.date=2016-11&rft.volume=18&rft.issue=6&rft.spage=1995&rft.epage=2009&rft.pages=1995-2009&rft.issn=1561-8625&rft.eissn=1934-6093&rft_id=info:doi/10.1002/asjc.1293&rft_dat=%3Cproquest_cross%3E4265705291%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3353-fe0e7e016837739fcaae2fa5c81d4f463b06ad6a5cad7f0d78f8d8deca9b734c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1844748721&rft_id=info:pmid/&rfr_iscdi=true |