Loading…
Nondestructive testing of pitting corrosion cracks in rivet of multilayer structures
This research proposes an ultrasonic testing method for inspecting pitting corrosion cracks in a rivet of multilayer structures. The system is a combination of a magnetic sensor array and an ultrasonic sensor. The magnetic sensor array is used to automatically measure the presence of a rivet and its...
Saved in:
Published in: | International journal of precision engineering and manufacturing 2016-11, Vol.17 (11), p.1433-1442 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This research proposes an ultrasonic testing method for inspecting pitting corrosion cracks in a rivet of multilayer structures. The system is a combination of a magnetic sensor array and an ultrasonic sensor. The magnetic sensor array is used to automatically measure the presence of a rivet and its center position. Then, the ultrasonic sensor is guided to the rivet center in order to inspect pitting corrosion cracks in the rivet. The magnetic sensor uses a 64-Hall sensor elements array with a 0.52-mm interval that can measure the rivet center position at a standard deviation of 0.27 mm and 0.42 mm in the scan and sensor directions, respectively. The ultrasonic signal is analyzed in the frequency domain using the short-time Fourier transform that helps better observe the presence of cracks compared with the conventional signal analysis in A-scan present. |
---|---|
ISSN: | 2234-7593 2005-4602 |
DOI: | 10.1007/s12541-016-0169-7 |