Loading…

Metabolic phenotyping of human plasma by 1H‐NMR at high and medium magnetic field strengths: a case study for lung cancer

Accurate identification and quantification of human plasma metabolites can be challenging in crowded regions of the NMR spectrum with severe signal overlap. Therefore, this study describes metabolite spiking experiments on the basis of which the NMR spectrum can be rationally segmented into well‐def...

Full description

Saved in:
Bibliographic Details
Published in:Magnetic resonance in chemistry 2017-08, Vol.55 (8), p.706-713
Main Authors: Louis, Evelyne, Cantrelle, Francois‐Xavier, Mesotten, Liesbet, Reekmans, Gunter, Bervoets, Liene, Vanhove, Karolien, Thomeer, Michiel, Lippens, Guy, Adriaensens, Peter
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 713
container_issue 8
container_start_page 706
container_title Magnetic resonance in chemistry
container_volume 55
creator Louis, Evelyne
Cantrelle, Francois‐Xavier
Mesotten, Liesbet
Reekmans, Gunter
Bervoets, Liene
Vanhove, Karolien
Thomeer, Michiel
Lippens, Guy
Adriaensens, Peter
description Accurate identification and quantification of human plasma metabolites can be challenging in crowded regions of the NMR spectrum with severe signal overlap. Therefore, this study describes metabolite spiking experiments on the basis of which the NMR spectrum can be rationally segmented into well‐defined integration regions, and this for spectrometers having magnetic field strengths corresponding to 1H resonance frequencies of 400 MHz and 900 MHz. Subsequently, the integration data of a case–control dataset of 69 lung cancer patients and 74 controls were used to train a multivariate statistical classification model for both field strengths. In this way, the advantages/disadvantages of high versus medium magnetic field strength were evaluated. The discriminative power obtained from the data collected at the two magnetic field strengths is rather similar, i.e. a sensitivity and specificity of respectively 90 and 97% for the 400 MHz data versus 88 and 96% for the 900 MHz data. This shows that a medium‐field NMR spectrometer (400–600 MHz) is already sufficient to perform clinical metabolomics. However, the improved spectral resolution (reduced signal overlap) and signal‐to‐noise ratio of 900 MHz spectra yield more integration regions that represent a single metabolite. This will simplify the unraveling and understanding of the related, disease disturbed, biochemical pathways. Copyright © 2017 John Wiley & Sons, Ltd. This study describes metabolite spiking experiments on the basis of which the 1H‐NMR spectrum can be segmented into well‐defined integration regions, and this for 400 and 900 MHz spectra. Subsequently, the integration data of a case–control dataset were used to train a multivariate classifier for both magnetic field strengths. The discriminative power of the resulting models is rather similar, i.e. a sensitivity and specificity of 90 and 97% for the 400 MHz data versus 88 and 96% for the 900 MHz data.
doi_str_mv 10.1002/mrc.4577
format article
fullrecord <record><control><sourceid>proquest_wiley</sourceid><recordid>TN_cdi_proquest_journals_1915708036</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1915708036</sourcerecordid><originalsourceid>FETCH-LOGICAL-p1517-6782a0f69d853fc464e875294f15feadd51a6f7c600fb35d90c831c0c53cd03a3</originalsourceid><addsrcrecordid>eNotkN9KwzAchYMoOKfgIwS8rv6yNE3jnQx1wqYwFLwLWf6sHW1akxYp3vgIPqNPYse8OnA4fAc-hC4JXBOA2U0d9HXKOD9CEwKCJynL34_RBHgqEsJycorOYtwBgBCcTtDXynZq01Slxm1hfdMNbem3uHG46GvlcVupWCu8GTBZ_H7_PK_WWHW4KLcFVt7g2pqyr3Gttt52I8OVtjI4dsH6bVfEW6ywVtGOTW8G7JqAq37Ea-W1DefoxKkq2ov_nKK3h_vX-SJZvjw-ze-WSUsY4UnG85kClwmTM-p0mqU252wmUkeYs8oYRlTmuM4A3IYyI0DnlGjQjGoDVNEpujpw29B89DZ2ctf0wY-XkgjCOORAs3GVHFafZWUH2YayVmGQBOTeqxy9yr1XuVrP90n_AMpmbgs</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1915708036</pqid></control><display><type>article</type><title>Metabolic phenotyping of human plasma by 1H‐NMR at high and medium magnetic field strengths: a case study for lung cancer</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Louis, Evelyne ; Cantrelle, Francois‐Xavier ; Mesotten, Liesbet ; Reekmans, Gunter ; Bervoets, Liene ; Vanhove, Karolien ; Thomeer, Michiel ; Lippens, Guy ; Adriaensens, Peter</creator><creatorcontrib>Louis, Evelyne ; Cantrelle, Francois‐Xavier ; Mesotten, Liesbet ; Reekmans, Gunter ; Bervoets, Liene ; Vanhove, Karolien ; Thomeer, Michiel ; Lippens, Guy ; Adriaensens, Peter</creatorcontrib><description>Accurate identification and quantification of human plasma metabolites can be challenging in crowded regions of the NMR spectrum with severe signal overlap. Therefore, this study describes metabolite spiking experiments on the basis of which the NMR spectrum can be rationally segmented into well‐defined integration regions, and this for spectrometers having magnetic field strengths corresponding to 1H resonance frequencies of 400 MHz and 900 MHz. Subsequently, the integration data of a case–control dataset of 69 lung cancer patients and 74 controls were used to train a multivariate statistical classification model for both field strengths. In this way, the advantages/disadvantages of high versus medium magnetic field strength were evaluated. The discriminative power obtained from the data collected at the two magnetic field strengths is rather similar, i.e. a sensitivity and specificity of respectively 90 and 97% for the 400 MHz data versus 88 and 96% for the 900 MHz data. This shows that a medium‐field NMR spectrometer (400–600 MHz) is already sufficient to perform clinical metabolomics. However, the improved spectral resolution (reduced signal overlap) and signal‐to‐noise ratio of 900 MHz spectra yield more integration regions that represent a single metabolite. This will simplify the unraveling and understanding of the related, disease disturbed, biochemical pathways. Copyright © 2017 John Wiley &amp; Sons, Ltd. This study describes metabolite spiking experiments on the basis of which the 1H‐NMR spectrum can be segmented into well‐defined integration regions, and this for 400 and 900 MHz spectra. Subsequently, the integration data of a case–control dataset were used to train a multivariate classifier for both magnetic field strengths. The discriminative power of the resulting models is rather similar, i.e. a sensitivity and specificity of 90 and 97% for the 400 MHz data versus 88 and 96% for the 900 MHz data.</description><identifier>ISSN: 0749-1581</identifier><identifier>EISSN: 1097-458X</identifier><identifier>DOI: 10.1002/mrc.4577</identifier><language>eng</language><publisher>Bognor Regis: Wiley Subscription Services, Inc</publisher><subject>1H, magnetic field strength ; Biochemistry ; Blood plasma ; Cancer ; Classification ; Field strength ; Lung cancer ; Magnetic fields ; metabolic phenotype ; Metabolites ; NMR ; Nuclear magnetic resonance ; nuclear magnetic resonance spectroscopy ; Patients ; Plasma ; Signal to noise ratio ; Spectral resolution ; Spectrometers ; Spiking</subject><ispartof>Magnetic resonance in chemistry, 2017-08, Vol.55 (8), p.706-713</ispartof><rights>Copyright © 2017 John Wiley &amp; Sons, Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><orcidid>0000-0003-4183-0150 ; 0000-0001-6600-2584</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Louis, Evelyne</creatorcontrib><creatorcontrib>Cantrelle, Francois‐Xavier</creatorcontrib><creatorcontrib>Mesotten, Liesbet</creatorcontrib><creatorcontrib>Reekmans, Gunter</creatorcontrib><creatorcontrib>Bervoets, Liene</creatorcontrib><creatorcontrib>Vanhove, Karolien</creatorcontrib><creatorcontrib>Thomeer, Michiel</creatorcontrib><creatorcontrib>Lippens, Guy</creatorcontrib><creatorcontrib>Adriaensens, Peter</creatorcontrib><title>Metabolic phenotyping of human plasma by 1H‐NMR at high and medium magnetic field strengths: a case study for lung cancer</title><title>Magnetic resonance in chemistry</title><description>Accurate identification and quantification of human plasma metabolites can be challenging in crowded regions of the NMR spectrum with severe signal overlap. Therefore, this study describes metabolite spiking experiments on the basis of which the NMR spectrum can be rationally segmented into well‐defined integration regions, and this for spectrometers having magnetic field strengths corresponding to 1H resonance frequencies of 400 MHz and 900 MHz. Subsequently, the integration data of a case–control dataset of 69 lung cancer patients and 74 controls were used to train a multivariate statistical classification model for both field strengths. In this way, the advantages/disadvantages of high versus medium magnetic field strength were evaluated. The discriminative power obtained from the data collected at the two magnetic field strengths is rather similar, i.e. a sensitivity and specificity of respectively 90 and 97% for the 400 MHz data versus 88 and 96% for the 900 MHz data. This shows that a medium‐field NMR spectrometer (400–600 MHz) is already sufficient to perform clinical metabolomics. However, the improved spectral resolution (reduced signal overlap) and signal‐to‐noise ratio of 900 MHz spectra yield more integration regions that represent a single metabolite. This will simplify the unraveling and understanding of the related, disease disturbed, biochemical pathways. Copyright © 2017 John Wiley &amp; Sons, Ltd. This study describes metabolite spiking experiments on the basis of which the 1H‐NMR spectrum can be segmented into well‐defined integration regions, and this for 400 and 900 MHz spectra. Subsequently, the integration data of a case–control dataset were used to train a multivariate classifier for both magnetic field strengths. The discriminative power of the resulting models is rather similar, i.e. a sensitivity and specificity of 90 and 97% for the 400 MHz data versus 88 and 96% for the 900 MHz data.</description><subject>1H, magnetic field strength</subject><subject>Biochemistry</subject><subject>Blood plasma</subject><subject>Cancer</subject><subject>Classification</subject><subject>Field strength</subject><subject>Lung cancer</subject><subject>Magnetic fields</subject><subject>metabolic phenotype</subject><subject>Metabolites</subject><subject>NMR</subject><subject>Nuclear magnetic resonance</subject><subject>nuclear magnetic resonance spectroscopy</subject><subject>Patients</subject><subject>Plasma</subject><subject>Signal to noise ratio</subject><subject>Spectral resolution</subject><subject>Spectrometers</subject><subject>Spiking</subject><issn>0749-1581</issn><issn>1097-458X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNotkN9KwzAchYMoOKfgIwS8rv6yNE3jnQx1wqYwFLwLWf6sHW1akxYp3vgIPqNPYse8OnA4fAc-hC4JXBOA2U0d9HXKOD9CEwKCJynL34_RBHgqEsJycorOYtwBgBCcTtDXynZq01Slxm1hfdMNbem3uHG46GvlcVupWCu8GTBZ_H7_PK_WWHW4KLcFVt7g2pqyr3Gttt52I8OVtjI4dsH6bVfEW6ywVtGOTW8G7JqAq37Ea-W1DefoxKkq2ov_nKK3h_vX-SJZvjw-ze-WSUsY4UnG85kClwmTM-p0mqU252wmUkeYs8oYRlTmuM4A3IYyI0DnlGjQjGoDVNEpujpw29B89DZ2ctf0wY-XkgjCOORAs3GVHFafZWUH2YayVmGQBOTeqxy9yr1XuVrP90n_AMpmbgs</recordid><startdate>201708</startdate><enddate>201708</enddate><creator>Louis, Evelyne</creator><creator>Cantrelle, Francois‐Xavier</creator><creator>Mesotten, Liesbet</creator><creator>Reekmans, Gunter</creator><creator>Bervoets, Liene</creator><creator>Vanhove, Karolien</creator><creator>Thomeer, Michiel</creator><creator>Lippens, Guy</creator><creator>Adriaensens, Peter</creator><general>Wiley Subscription Services, Inc</general><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>JQ2</scope><scope>K9.</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0003-4183-0150</orcidid><orcidid>https://orcid.org/0000-0001-6600-2584</orcidid></search><sort><creationdate>201708</creationdate><title>Metabolic phenotyping of human plasma by 1H‐NMR at high and medium magnetic field strengths: a case study for lung cancer</title><author>Louis, Evelyne ; Cantrelle, Francois‐Xavier ; Mesotten, Liesbet ; Reekmans, Gunter ; Bervoets, Liene ; Vanhove, Karolien ; Thomeer, Michiel ; Lippens, Guy ; Adriaensens, Peter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p1517-6782a0f69d853fc464e875294f15feadd51a6f7c600fb35d90c831c0c53cd03a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>1H, magnetic field strength</topic><topic>Biochemistry</topic><topic>Blood plasma</topic><topic>Cancer</topic><topic>Classification</topic><topic>Field strength</topic><topic>Lung cancer</topic><topic>Magnetic fields</topic><topic>metabolic phenotype</topic><topic>Metabolites</topic><topic>NMR</topic><topic>Nuclear magnetic resonance</topic><topic>nuclear magnetic resonance spectroscopy</topic><topic>Patients</topic><topic>Plasma</topic><topic>Signal to noise ratio</topic><topic>Spectral resolution</topic><topic>Spectrometers</topic><topic>Spiking</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Louis, Evelyne</creatorcontrib><creatorcontrib>Cantrelle, Francois‐Xavier</creatorcontrib><creatorcontrib>Mesotten, Liesbet</creatorcontrib><creatorcontrib>Reekmans, Gunter</creatorcontrib><creatorcontrib>Bervoets, Liene</creatorcontrib><creatorcontrib>Vanhove, Karolien</creatorcontrib><creatorcontrib>Thomeer, Michiel</creatorcontrib><creatorcontrib>Lippens, Guy</creatorcontrib><creatorcontrib>Adriaensens, Peter</creatorcontrib><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Magnetic resonance in chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Louis, Evelyne</au><au>Cantrelle, Francois‐Xavier</au><au>Mesotten, Liesbet</au><au>Reekmans, Gunter</au><au>Bervoets, Liene</au><au>Vanhove, Karolien</au><au>Thomeer, Michiel</au><au>Lippens, Guy</au><au>Adriaensens, Peter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Metabolic phenotyping of human plasma by 1H‐NMR at high and medium magnetic field strengths: a case study for lung cancer</atitle><jtitle>Magnetic resonance in chemistry</jtitle><date>2017-08</date><risdate>2017</risdate><volume>55</volume><issue>8</issue><spage>706</spage><epage>713</epage><pages>706-713</pages><issn>0749-1581</issn><eissn>1097-458X</eissn><abstract>Accurate identification and quantification of human plasma metabolites can be challenging in crowded regions of the NMR spectrum with severe signal overlap. Therefore, this study describes metabolite spiking experiments on the basis of which the NMR spectrum can be rationally segmented into well‐defined integration regions, and this for spectrometers having magnetic field strengths corresponding to 1H resonance frequencies of 400 MHz and 900 MHz. Subsequently, the integration data of a case–control dataset of 69 lung cancer patients and 74 controls were used to train a multivariate statistical classification model for both field strengths. In this way, the advantages/disadvantages of high versus medium magnetic field strength were evaluated. The discriminative power obtained from the data collected at the two magnetic field strengths is rather similar, i.e. a sensitivity and specificity of respectively 90 and 97% for the 400 MHz data versus 88 and 96% for the 900 MHz data. This shows that a medium‐field NMR spectrometer (400–600 MHz) is already sufficient to perform clinical metabolomics. However, the improved spectral resolution (reduced signal overlap) and signal‐to‐noise ratio of 900 MHz spectra yield more integration regions that represent a single metabolite. This will simplify the unraveling and understanding of the related, disease disturbed, biochemical pathways. Copyright © 2017 John Wiley &amp; Sons, Ltd. This study describes metabolite spiking experiments on the basis of which the 1H‐NMR spectrum can be segmented into well‐defined integration regions, and this for 400 and 900 MHz spectra. Subsequently, the integration data of a case–control dataset were used to train a multivariate classifier for both magnetic field strengths. The discriminative power of the resulting models is rather similar, i.e. a sensitivity and specificity of 90 and 97% for the 400 MHz data versus 88 and 96% for the 900 MHz data.</abstract><cop>Bognor Regis</cop><pub>Wiley Subscription Services, Inc</pub><doi>10.1002/mrc.4577</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0003-4183-0150</orcidid><orcidid>https://orcid.org/0000-0001-6600-2584</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0749-1581
ispartof Magnetic resonance in chemistry, 2017-08, Vol.55 (8), p.706-713
issn 0749-1581
1097-458X
language eng
recordid cdi_proquest_journals_1915708036
source Wiley-Blackwell Read & Publish Collection
subjects 1H, magnetic field strength
Biochemistry
Blood plasma
Cancer
Classification
Field strength
Lung cancer
Magnetic fields
metabolic phenotype
Metabolites
NMR
Nuclear magnetic resonance
nuclear magnetic resonance spectroscopy
Patients
Plasma
Signal to noise ratio
Spectral resolution
Spectrometers
Spiking
title Metabolic phenotyping of human plasma by 1H‐NMR at high and medium magnetic field strengths: a case study for lung cancer
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T22%3A27%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_wiley&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Metabolic%20phenotyping%20of%20human%20plasma%20by%201H%E2%80%90NMR%20at%20high%20and%20medium%20magnetic%20field%20strengths:%20a%20case%20study%20for%20lung%20cancer&rft.jtitle=Magnetic%20resonance%20in%20chemistry&rft.au=Louis,%20Evelyne&rft.date=2017-08&rft.volume=55&rft.issue=8&rft.spage=706&rft.epage=713&rft.pages=706-713&rft.issn=0749-1581&rft.eissn=1097-458X&rft_id=info:doi/10.1002/mrc.4577&rft_dat=%3Cproquest_wiley%3E1915708036%3C/proquest_wiley%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p1517-6782a0f69d853fc464e875294f15feadd51a6f7c600fb35d90c831c0c53cd03a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1915708036&rft_id=info:pmid/&rfr_iscdi=true