Energy and exergy assessment in a perimeter cooled data center: The value of second law efficiency

•This work focusses on Data Center power consumption in the early years of operation.•Maximum efficiency appears with all racks active in contained aisles.•The Coefficient of Performance proves insufficient to address irreversibilities.•The use of the second law efficiency in these Thermodynamic ana...

Full description

Saved in:
Bibliographic Details
Published in:Applied thermal engineering 2017-09, Vol.124, p.820-830
Main Authors: Díaz, Andrés J., Cáceres, Rodrigo, Cardemil, José M., Silva-Llanca, Luis
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c358t-b3fecfeaa4978526a4bec2192a8c623ff74f94fd360db36e3acc864cf21f1ac53
cites cdi_FETCH-LOGICAL-c358t-b3fecfeaa4978526a4bec2192a8c623ff74f94fd360db36e3acc864cf21f1ac53
container_end_page 830
container_issue
container_start_page 820
container_title Applied thermal engineering
container_volume 124
creator Díaz, Andrés J.
Cáceres, Rodrigo
Cardemil, José M.
Silva-Llanca, Luis
description •This work focusses on Data Center power consumption in the early years of operation.•Maximum efficiency appears with all racks active in contained aisles.•The Coefficient of Performance proves insufficient to address irreversibilities.•The use of the second law efficiency in these Thermodynamic analyses is suggested. The Data Center Industry remains in steady growth with worldwide energy consumptions in the order of hundreds of TWh, and yearly growth rates higher than the growth of global electricity consumption. Electronic cooling represents an important part of a Data Center’s energy demand, thus efficient thermal management practices have become critical in recent years. The Coefficient of Performance (COP) appears as the most commonly used metric when assessing the energy efficiency of a data center, although sometimes it proves insufficient to address irreversibilities in a system. In this work, the information provided by the COP is complemented with a second law efficiency analysis as a way to measure inefficiencies. The software Engineering Equation Solver (EES) is utilized to apply energy and exergy balances in each individual component and the global refrigeration system, simultaneously. The study considers variations in the number of active racks and the increase in hot air recirculation within the room, assuming that the approach closely represents the first years of operation. Maximum efficiencies are achieved when all racks are active and when aisle air containment prevents recirculation. Fewer active racks increase the exergy destruction, due to excessive power usage in a low demand situation. The chiller accounts for the highest power consumption with high density racks; whereas for low density racks, the cooling tower consumes most of the power. The second law analysis justifies the chiller power consumption based on its cooling requirements, and elucidates oversizing in the cooling tower power consumption. The COP increases with hot air recirculation, which could mislead the design towards inefficient decisions; the second law efficiency shows an inverse relationship with the recirculation, thus properly capturing the inefficiencies and better guiding the design. Appropriate energy efficiency analyses should consider both thermodynamic approaches (first and second law) to ensure proper use of working fluids cooling potential and maximize the system energy efficiency.
doi_str_mv 10.1016/j.applthermaleng.2017.06.066
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_1939917731</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1359431116326746</els_id><sourcerecordid>1939917731</sourcerecordid><originalsourceid>FETCH-LOGICAL-c358t-b3fecfeaa4978526a4bec2192a8c623ff74f94fd360db36e3acc864cf21f1ac53</originalsourceid><addsrcrecordid>eNqNUNFKwzAUDaLgnP5DQF9bk6ZNW_FFxqbCwJf5HG7Tm62ja2rSTff3ZtYX34QD98I951zOIeSOs5gzLu-3MfR9O2zQ7aDFbh0njOcxkwHyjEx4kYsok0yeh11kZZQKzi_JlfdbxnhS5OmEVPMO3fpIoaspfo2r9-j9DruBNh0F2qNrdjigo9raFmtawwBUhzu6B7raID1Au0dqDfWobTBq4ZOiMY1usNPHa3JhoPV48zun5H0xX81eouXb8-vsaRlpkRVDVAmD2iBAWuZFlkhIK9QJLxMotEyEMXlqytTUQrK6EhIFaF3IVJuEGw46E1NyO_r2zn7s0Q9qa_euCy8VL0VZ8jwXPLAeR5Z21nuHRvUhHrij4kydWlVb9bdVdWpVMRkgg3wxyjEkOTTolP9JiXXjUA-qts3_jL4BF7SLKg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1939917731</pqid></control><display><type>article</type><title>Energy and exergy assessment in a perimeter cooled data center: The value of second law efficiency</title><source>ScienceDirect Freedom Collection</source><creator>Díaz, Andrés J. ; Cáceres, Rodrigo ; Cardemil, José M. ; Silva-Llanca, Luis</creator><creatorcontrib>Díaz, Andrés J. ; Cáceres, Rodrigo ; Cardemil, José M. ; Silva-Llanca, Luis</creatorcontrib><description>•This work focusses on Data Center power consumption in the early years of operation.•Maximum efficiency appears with all racks active in contained aisles.•The Coefficient of Performance proves insufficient to address irreversibilities.•The use of the second law efficiency in these Thermodynamic analyses is suggested. The Data Center Industry remains in steady growth with worldwide energy consumptions in the order of hundreds of TWh, and yearly growth rates higher than the growth of global electricity consumption. Electronic cooling represents an important part of a Data Center’s energy demand, thus efficient thermal management practices have become critical in recent years. The Coefficient of Performance (COP) appears as the most commonly used metric when assessing the energy efficiency of a data center, although sometimes it proves insufficient to address irreversibilities in a system. In this work, the information provided by the COP is complemented with a second law efficiency analysis as a way to measure inefficiencies. The software Engineering Equation Solver (EES) is utilized to apply energy and exergy balances in each individual component and the global refrigeration system, simultaneously. The study considers variations in the number of active racks and the increase in hot air recirculation within the room, assuming that the approach closely represents the first years of operation. Maximum efficiencies are achieved when all racks are active and when aisle air containment prevents recirculation. Fewer active racks increase the exergy destruction, due to excessive power usage in a low demand situation. The chiller accounts for the highest power consumption with high density racks; whereas for low density racks, the cooling tower consumes most of the power. The second law analysis justifies the chiller power consumption based on its cooling requirements, and elucidates oversizing in the cooling tower power consumption. The COP increases with hot air recirculation, which could mislead the design towards inefficient decisions; the second law efficiency shows an inverse relationship with the recirculation, thus properly capturing the inefficiencies and better guiding the design. Appropriate energy efficiency analyses should consider both thermodynamic approaches (first and second law) to ensure proper use of working fluids cooling potential and maximize the system energy efficiency.</description><identifier>ISSN: 1359-4311</identifier><identifier>EISSN: 1873-5606</identifier><identifier>DOI: 10.1016/j.applthermaleng.2017.06.066</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Air recirculation ; Computer centers ; Containment ; Cooling ; Cooling rate ; Cooling system ; Cooling towers ; Data center ; Electricity consumption ; Energy consumption ; Energy efficiency ; Energy management ; Exergy ; Exergy destruction ; Power consumption ; Power efficiency ; Racks ; Refrigeration ; Software engineering ; Thermal management ; Working fluids</subject><ispartof>Applied thermal engineering, 2017-09, Vol.124, p.820-830</ispartof><rights>2017 Elsevier Ltd</rights><rights>Copyright Elsevier BV Sep 2017</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c358t-b3fecfeaa4978526a4bec2192a8c623ff74f94fd360db36e3acc864cf21f1ac53</citedby><cites>FETCH-LOGICAL-c358t-b3fecfeaa4978526a4bec2192a8c623ff74f94fd360db36e3acc864cf21f1ac53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27907,27908</link.rule.ids></links><search><creatorcontrib>Díaz, Andrés J.</creatorcontrib><creatorcontrib>Cáceres, Rodrigo</creatorcontrib><creatorcontrib>Cardemil, José M.</creatorcontrib><creatorcontrib>Silva-Llanca, Luis</creatorcontrib><title>Energy and exergy assessment in a perimeter cooled data center: The value of second law efficiency</title><title>Applied thermal engineering</title><description>•This work focusses on Data Center power consumption in the early years of operation.•Maximum efficiency appears with all racks active in contained aisles.•The Coefficient of Performance proves insufficient to address irreversibilities.•The use of the second law efficiency in these Thermodynamic analyses is suggested. The Data Center Industry remains in steady growth with worldwide energy consumptions in the order of hundreds of TWh, and yearly growth rates higher than the growth of global electricity consumption. Electronic cooling represents an important part of a Data Center’s energy demand, thus efficient thermal management practices have become critical in recent years. The Coefficient of Performance (COP) appears as the most commonly used metric when assessing the energy efficiency of a data center, although sometimes it proves insufficient to address irreversibilities in a system. In this work, the information provided by the COP is complemented with a second law efficiency analysis as a way to measure inefficiencies. The software Engineering Equation Solver (EES) is utilized to apply energy and exergy balances in each individual component and the global refrigeration system, simultaneously. The study considers variations in the number of active racks and the increase in hot air recirculation within the room, assuming that the approach closely represents the first years of operation. Maximum efficiencies are achieved when all racks are active and when aisle air containment prevents recirculation. Fewer active racks increase the exergy destruction, due to excessive power usage in a low demand situation. The chiller accounts for the highest power consumption with high density racks; whereas for low density racks, the cooling tower consumes most of the power. The second law analysis justifies the chiller power consumption based on its cooling requirements, and elucidates oversizing in the cooling tower power consumption. The COP increases with hot air recirculation, which could mislead the design towards inefficient decisions; the second law efficiency shows an inverse relationship with the recirculation, thus properly capturing the inefficiencies and better guiding the design. Appropriate energy efficiency analyses should consider both thermodynamic approaches (first and second law) to ensure proper use of working fluids cooling potential and maximize the system energy efficiency.</description><subject>Air recirculation</subject><subject>Computer centers</subject><subject>Containment</subject><subject>Cooling</subject><subject>Cooling rate</subject><subject>Cooling system</subject><subject>Cooling towers</subject><subject>Data center</subject><subject>Electricity consumption</subject><subject>Energy consumption</subject><subject>Energy efficiency</subject><subject>Energy management</subject><subject>Exergy</subject><subject>Exergy destruction</subject><subject>Power consumption</subject><subject>Power efficiency</subject><subject>Racks</subject><subject>Refrigeration</subject><subject>Software engineering</subject><subject>Thermal management</subject><subject>Working fluids</subject><issn>1359-4311</issn><issn>1873-5606</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqNUNFKwzAUDaLgnP5DQF9bk6ZNW_FFxqbCwJf5HG7Tm62ja2rSTff3ZtYX34QD98I951zOIeSOs5gzLu-3MfR9O2zQ7aDFbh0njOcxkwHyjEx4kYsok0yeh11kZZQKzi_JlfdbxnhS5OmEVPMO3fpIoaspfo2r9-j9DruBNh0F2qNrdjigo9raFmtawwBUhzu6B7raID1Au0dqDfWobTBq4ZOiMY1usNPHa3JhoPV48zun5H0xX81eouXb8-vsaRlpkRVDVAmD2iBAWuZFlkhIK9QJLxMotEyEMXlqytTUQrK6EhIFaF3IVJuEGw46E1NyO_r2zn7s0Q9qa_euCy8VL0VZ8jwXPLAeR5Z21nuHRvUhHrij4kydWlVb9bdVdWpVMRkgg3wxyjEkOTTolP9JiXXjUA-qts3_jL4BF7SLKg</recordid><startdate>20170901</startdate><enddate>20170901</enddate><creator>Díaz, Andrés J.</creator><creator>Cáceres, Rodrigo</creator><creator>Cardemil, José M.</creator><creator>Silva-Llanca, Luis</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20170901</creationdate><title>Energy and exergy assessment in a perimeter cooled data center: The value of second law efficiency</title><author>Díaz, Andrés J. ; Cáceres, Rodrigo ; Cardemil, José M. ; Silva-Llanca, Luis</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c358t-b3fecfeaa4978526a4bec2192a8c623ff74f94fd360db36e3acc864cf21f1ac53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Air recirculation</topic><topic>Computer centers</topic><topic>Containment</topic><topic>Cooling</topic><topic>Cooling rate</topic><topic>Cooling system</topic><topic>Cooling towers</topic><topic>Data center</topic><topic>Electricity consumption</topic><topic>Energy consumption</topic><topic>Energy efficiency</topic><topic>Energy management</topic><topic>Exergy</topic><topic>Exergy destruction</topic><topic>Power consumption</topic><topic>Power efficiency</topic><topic>Racks</topic><topic>Refrigeration</topic><topic>Software engineering</topic><topic>Thermal management</topic><topic>Working fluids</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Díaz, Andrés J.</creatorcontrib><creatorcontrib>Cáceres, Rodrigo</creatorcontrib><creatorcontrib>Cardemil, José M.</creatorcontrib><creatorcontrib>Silva-Llanca, Luis</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Applied thermal engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Díaz, Andrés J.</au><au>Cáceres, Rodrigo</au><au>Cardemil, José M.</au><au>Silva-Llanca, Luis</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Energy and exergy assessment in a perimeter cooled data center: The value of second law efficiency</atitle><jtitle>Applied thermal engineering</jtitle><date>2017-09-01</date><risdate>2017</risdate><volume>124</volume><spage>820</spage><epage>830</epage><pages>820-830</pages><issn>1359-4311</issn><eissn>1873-5606</eissn><abstract>•This work focusses on Data Center power consumption in the early years of operation.•Maximum efficiency appears with all racks active in contained aisles.•The Coefficient of Performance proves insufficient to address irreversibilities.•The use of the second law efficiency in these Thermodynamic analyses is suggested. The Data Center Industry remains in steady growth with worldwide energy consumptions in the order of hundreds of TWh, and yearly growth rates higher than the growth of global electricity consumption. Electronic cooling represents an important part of a Data Center’s energy demand, thus efficient thermal management practices have become critical in recent years. The Coefficient of Performance (COP) appears as the most commonly used metric when assessing the energy efficiency of a data center, although sometimes it proves insufficient to address irreversibilities in a system. In this work, the information provided by the COP is complemented with a second law efficiency analysis as a way to measure inefficiencies. The software Engineering Equation Solver (EES) is utilized to apply energy and exergy balances in each individual component and the global refrigeration system, simultaneously. The study considers variations in the number of active racks and the increase in hot air recirculation within the room, assuming that the approach closely represents the first years of operation. Maximum efficiencies are achieved when all racks are active and when aisle air containment prevents recirculation. Fewer active racks increase the exergy destruction, due to excessive power usage in a low demand situation. The chiller accounts for the highest power consumption with high density racks; whereas for low density racks, the cooling tower consumes most of the power. The second law analysis justifies the chiller power consumption based on its cooling requirements, and elucidates oversizing in the cooling tower power consumption. The COP increases with hot air recirculation, which could mislead the design towards inefficient decisions; the second law efficiency shows an inverse relationship with the recirculation, thus properly capturing the inefficiencies and better guiding the design. Appropriate energy efficiency analyses should consider both thermodynamic approaches (first and second law) to ensure proper use of working fluids cooling potential and maximize the system energy efficiency.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.applthermaleng.2017.06.066</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1359-4311
ispartof Applied thermal engineering, 2017-09, Vol.124, p.820-830
issn 1359-4311
1873-5606
language eng
recordid cdi_proquest_journals_1939917731
source ScienceDirect Freedom Collection
subjects Air recirculation
Computer centers
Containment
Cooling
Cooling rate
Cooling system
Cooling towers
Data center
Electricity consumption
Energy consumption
Energy efficiency
Energy management
Exergy
Exergy destruction
Power consumption
Power efficiency
Racks
Refrigeration
Software engineering
Thermal management
Working fluids
title Energy and exergy assessment in a perimeter cooled data center: The value of second law efficiency
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T21%3A52%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Energy%20and%20exergy%20assessment%20in%20a%20perimeter%20cooled%20data%20center:%20The%20value%20of%20second%20law%20efficiency&rft.jtitle=Applied%20thermal%20engineering&rft.au=D%C3%ADaz,%20Andr%C3%A9s%20J.&rft.date=2017-09-01&rft.volume=124&rft.spage=820&rft.epage=830&rft.pages=820-830&rft.issn=1359-4311&rft.eissn=1873-5606&rft_id=info:doi/10.1016/j.applthermaleng.2017.06.066&rft_dat=%3Cproquest_cross%3E1939917731%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c358t-b3fecfeaa4978526a4bec2192a8c623ff74f94fd360db36e3acc864cf21f1ac53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1939917731&rft_id=info:pmid/&rfr_iscdi=true