Loading…

Comparison of HF and HCl cross-contamination between different ENTEGRIS FOUP platforms and Cu-coated wafers

In this work, a comparative study of three different Entegris FOUP platforms and materials (PC, PC/CP and EBM/CNT) is carried out in order to assess and compare their capacity to be contaminated by HF and HCl, their molecular outgassing caused by the same contamination dose and their actual contamin...

Full description

Saved in:
Bibliographic Details
Published in:Microelectronic engineering 2017-02, Vol.169, p.34-38
Main Authors: Herrán, Fernando, González-Aguirre, Paola, Beitia, Carlos, Ohlsen, Jim, Lundgren, Jorgen, Fontaine, Hervé
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this work, a comparative study of three different Entegris FOUP platforms and materials (PC, PC/CP and EBM/CNT) is carried out in order to assess and compare their capacity to be contaminated by HF and HCl, their molecular outgassing caused by the same contamination dose and their actual contamination transfer to Cu-coated wafers exposed within each FOUP. The results presented hereby allow us to evidence the higher mobility and affinity of the HF for the polymers of the FOUP and the Cu-coated wafers with respect to the HCl case. It is also demonstrated that high outgassing concentrations are not directly related to a large contamination transfer to wafers since each phenomenon is predominantly governed by the solubility or diffusivity parameter respectively. Furthermore, the EBM/CNT FOUP arises as the best of the three tested FOUPs in terms of contamination transfer to the Cu-coated wafers due to its lower HF and HCl affinities shown during the contamination phase regarding the others (PC and PC/CP FOUPs). Definitely, it is highly recommended to follow an experimental wafer exposure protocol in order to decide the suitability of a FOUP according to any sensitive fabrication step whatsoever. [Display omitted] •The faster HF uptake evidences a higher permeation rate (affinity) regarding HCl.•The higher HF-polymer solubility implies lower HF outgassing concentrations.•The larger FOUP to wafer HF transfer results from a higher HF-polymer diffusivity.•The best FOUP in this study must minimize HX transfer to wafers: EBM/CNT.•Wafer exposure is recommended for FOUP evaluation: outgassing might be misleading.
ISSN:0167-9317
1873-5568