Loading…

Evaluating previous thermal treatment of chicken patties by visible/near-infrared spectroscopy

Cooking history at the center point in chicken patties was quantified in terms of both time-temperature integrated indices (C and F) and endpoint temperature (T(max)). Intact cooked patties were scanned for reflectance and transmittance spectroscopy. Reflectance resulted in better calibrations for t...

Full description

Saved in:
Bibliographic Details
Published in:Journal of food science 1997-07, Vol.62 (4), p.753-780
Main Authors: Chen, H. (University of Arkansas, Fayetteville, AR.), Marks, B.P
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c5013-1b80289d6d918e2eaf4c508ca727a382e0fa0fce84f87e60dcc35962c624c0713
cites cdi_FETCH-LOGICAL-c5013-1b80289d6d918e2eaf4c508ca727a382e0fa0fce84f87e60dcc35962c624c0713
container_end_page 780
container_issue 4
container_start_page 753
container_title Journal of food science
container_volume 62
creator Chen, H. (University of Arkansas, Fayetteville, AR.)
Marks, B.P
description Cooking history at the center point in chicken patties was quantified in terms of both time-temperature integrated indices (C and F) and endpoint temperature (T(max)). Intact cooked patties were scanned for reflectance and transmittance spectroscopy. Reflectance resulted in better calibrations for the indices of thermal history than did transmittance. Three reflectance wavelength ranges, visible (400 to 700 nm), near-infrared (1100 to 2500 nm), and visible/near-infrared (400 to 2500 nm), were evaluated, and visible/near-infrared yielded the highest accuracy. The best calibration resulted in a standard error of prediction (SEP) of 0.11 log10(min) for log10C, 0.25 log10(min) for log10F, and 2.54 degrees C for T(max) on an independent validation sample set
doi_str_mv 10.1111/j.1365-2621.1997.tb15450.x
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_194378080</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>22517213</sourcerecordid><originalsourceid>FETCH-LOGICAL-c5013-1b80289d6d918e2eaf4c508ca727a382e0fa0fce84f87e60dcc35962c624c0713</originalsourceid><addsrcrecordid>eNqVkEtvEzEUhUcIpIbCT6hkVWxn6sf4MWwQ9AWoCotQdVfLca5bp5OZwXZC8u_xaKLu8ebK8rnfOT5FcU5wRfK5WFeECV5SQUlFmkZWaUl4zXG1f1PMiOS4ZKomb4sZxpSWhNTypHgf4xqPdyZmxeP1zrRbk3z3hIYAO99vI0rPEDamRSmASRvoEuodss_evkCHBpOSh4iWB7Tz0S9buOjAhNJ3LpgAKxQHsCn00fbD4UPxzpk2wsfjPC3ub65_X34v737d_rj8eldajgkryVJhqpqVWDVEAQXj6vygrJFUGqYoYGews6BqpyQIvLKW8UZQK2htsSTstDifuEPo_2whJr3ut6HLlpo0NZMKK5xFnyeRzeliAKeH4DcmHDTBeqxTr_VYpx7r1GOd-lin3uflT0cHE61p81876-MrgcqGYz4G-TLJ_voWDv9hoH_eXC0kZ5lQTgQfE-xfCSa8aCGZ5Pphfquv5vNvSiwyKevPJr0zvTZPIYe6X4xsLIXkgv0Drk6jGA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>194378080</pqid></control><display><type>article</type><title>Evaluating previous thermal treatment of chicken patties by visible/near-infrared spectroscopy</title><source>Wiley</source><creator>Chen, H. (University of Arkansas, Fayetteville, AR.) ; Marks, B.P</creator><creatorcontrib>Chen, H. (University of Arkansas, Fayetteville, AR.) ; Marks, B.P</creatorcontrib><description>Cooking history at the center point in chicken patties was quantified in terms of both time-temperature integrated indices (C and F) and endpoint temperature (T(max)). Intact cooked patties were scanned for reflectance and transmittance spectroscopy. Reflectance resulted in better calibrations for the indices of thermal history than did transmittance. Three reflectance wavelength ranges, visible (400 to 700 nm), near-infrared (1100 to 2500 nm), and visible/near-infrared (400 to 2500 nm), were evaluated, and visible/near-infrared yielded the highest accuracy. The best calibration resulted in a standard error of prediction (SEP) of 0.11 log10(min) for log10C, 0.25 log10(min) for log10F, and 2.54 degrees C for T(max) on an independent validation sample set</description><identifier>ISSN: 0022-1147</identifier><identifier>EISSN: 1750-3841</identifier><identifier>DOI: 10.1111/j.1365-2621.1997.tb15450.x</identifier><identifier>CODEN: JFDSAZ</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>ALIMENTOS ; Biological and medical sciences ; CARNE DE POLLO ; chicken ; CHICKEN MEAT ; Cooking ; FOOD ANALYSIS ; Food industries ; Food science ; FOODS ; Fundamental and applied biological sciences. Psychology ; HEAT TREATMENT ; Meat and meat product industries ; near infrared spectroscopy ; Poultry ; PRODUIT ALIMENTAIRE ; Scientific imaging ; Temperature ; thermal history ; TRAITEMENT THERMIQUE ; TRATAMIENTO TERMICO ; VIANDE DE POULET</subject><ispartof>Journal of food science, 1997-07, Vol.62 (4), p.753-780</ispartof><rights>1997 INIST-CNRS</rights><rights>Copyright Institute of Food Technologists Jul 1997</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c5013-1b80289d6d918e2eaf4c508ca727a382e0fa0fce84f87e60dcc35962c624c0713</citedby><cites>FETCH-LOGICAL-c5013-1b80289d6d918e2eaf4c508ca727a382e0fa0fce84f87e60dcc35962c624c0713</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=2795051$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Chen, H. (University of Arkansas, Fayetteville, AR.)</creatorcontrib><creatorcontrib>Marks, B.P</creatorcontrib><title>Evaluating previous thermal treatment of chicken patties by visible/near-infrared spectroscopy</title><title>Journal of food science</title><description>Cooking history at the center point in chicken patties was quantified in terms of both time-temperature integrated indices (C and F) and endpoint temperature (T(max)). Intact cooked patties were scanned for reflectance and transmittance spectroscopy. Reflectance resulted in better calibrations for the indices of thermal history than did transmittance. Three reflectance wavelength ranges, visible (400 to 700 nm), near-infrared (1100 to 2500 nm), and visible/near-infrared (400 to 2500 nm), were evaluated, and visible/near-infrared yielded the highest accuracy. The best calibration resulted in a standard error of prediction (SEP) of 0.11 log10(min) for log10C, 0.25 log10(min) for log10F, and 2.54 degrees C for T(max) on an independent validation sample set</description><subject>ALIMENTOS</subject><subject>Biological and medical sciences</subject><subject>CARNE DE POLLO</subject><subject>chicken</subject><subject>CHICKEN MEAT</subject><subject>Cooking</subject><subject>FOOD ANALYSIS</subject><subject>Food industries</subject><subject>Food science</subject><subject>FOODS</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>HEAT TREATMENT</subject><subject>Meat and meat product industries</subject><subject>near infrared spectroscopy</subject><subject>Poultry</subject><subject>PRODUIT ALIMENTAIRE</subject><subject>Scientific imaging</subject><subject>Temperature</subject><subject>thermal history</subject><subject>TRAITEMENT THERMIQUE</subject><subject>TRATAMIENTO TERMICO</subject><subject>VIANDE DE POULET</subject><issn>0022-1147</issn><issn>1750-3841</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNqVkEtvEzEUhUcIpIbCT6hkVWxn6sf4MWwQ9AWoCotQdVfLca5bp5OZwXZC8u_xaKLu8ebK8rnfOT5FcU5wRfK5WFeECV5SQUlFmkZWaUl4zXG1f1PMiOS4ZKomb4sZxpSWhNTypHgf4xqPdyZmxeP1zrRbk3z3hIYAO99vI0rPEDamRSmASRvoEuodss_evkCHBpOSh4iWB7Tz0S9buOjAhNJ3LpgAKxQHsCn00fbD4UPxzpk2wsfjPC3ub65_X34v737d_rj8eldajgkryVJhqpqVWDVEAQXj6vygrJFUGqYoYGews6BqpyQIvLKW8UZQK2htsSTstDifuEPo_2whJr3ut6HLlpo0NZMKK5xFnyeRzeliAKeH4DcmHDTBeqxTr_VYpx7r1GOd-lin3uflT0cHE61p81876-MrgcqGYz4G-TLJ_voWDv9hoH_eXC0kZ5lQTgQfE-xfCSa8aCGZ5Pphfquv5vNvSiwyKevPJr0zvTZPIYe6X4xsLIXkgv0Drk6jGA</recordid><startdate>199707</startdate><enddate>199707</enddate><creator>Chen, H. (University of Arkansas, Fayetteville, AR.)</creator><creator>Marks, B.P</creator><general>Blackwell Publishing Ltd</general><general>Institute of Food Technologists</general><general>Wiley Subscription Services, Inc</general><scope>FBQ</scope><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>7QR</scope><scope>7ST</scope><scope>7T7</scope><scope>7U7</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>P64</scope><scope>RC3</scope><scope>SOI</scope></search><sort><creationdate>199707</creationdate><title>Evaluating previous thermal treatment of chicken patties by visible/near-infrared spectroscopy</title><author>Chen, H. (University of Arkansas, Fayetteville, AR.) ; Marks, B.P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c5013-1b80289d6d918e2eaf4c508ca727a382e0fa0fce84f87e60dcc35962c624c0713</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>ALIMENTOS</topic><topic>Biological and medical sciences</topic><topic>CARNE DE POLLO</topic><topic>chicken</topic><topic>CHICKEN MEAT</topic><topic>Cooking</topic><topic>FOOD ANALYSIS</topic><topic>Food industries</topic><topic>Food science</topic><topic>FOODS</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>HEAT TREATMENT</topic><topic>Meat and meat product industries</topic><topic>near infrared spectroscopy</topic><topic>Poultry</topic><topic>PRODUIT ALIMENTAIRE</topic><topic>Scientific imaging</topic><topic>Temperature</topic><topic>thermal history</topic><topic>TRAITEMENT THERMIQUE</topic><topic>TRATAMIENTO TERMICO</topic><topic>VIANDE DE POULET</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, H. (University of Arkansas, Fayetteville, AR.)</creatorcontrib><creatorcontrib>Marks, B.P</creatorcontrib><collection>AGRIS</collection><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Chemoreception Abstracts</collection><collection>Environment Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Toxicology Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Genetics Abstracts</collection><collection>Environment Abstracts</collection><jtitle>Journal of food science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, H. (University of Arkansas, Fayetteville, AR.)</au><au>Marks, B.P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluating previous thermal treatment of chicken patties by visible/near-infrared spectroscopy</atitle><jtitle>Journal of food science</jtitle><date>1997-07</date><risdate>1997</risdate><volume>62</volume><issue>4</issue><spage>753</spage><epage>780</epage><pages>753-780</pages><issn>0022-1147</issn><eissn>1750-3841</eissn><coden>JFDSAZ</coden><abstract>Cooking history at the center point in chicken patties was quantified in terms of both time-temperature integrated indices (C and F) and endpoint temperature (T(max)). Intact cooked patties were scanned for reflectance and transmittance spectroscopy. Reflectance resulted in better calibrations for the indices of thermal history than did transmittance. Three reflectance wavelength ranges, visible (400 to 700 nm), near-infrared (1100 to 2500 nm), and visible/near-infrared (400 to 2500 nm), were evaluated, and visible/near-infrared yielded the highest accuracy. The best calibration resulted in a standard error of prediction (SEP) of 0.11 log10(min) for log10C, 0.25 log10(min) for log10F, and 2.54 degrees C for T(max) on an independent validation sample set</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><doi>10.1111/j.1365-2621.1997.tb15450.x</doi><tpages>28</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0022-1147
ispartof Journal of food science, 1997-07, Vol.62 (4), p.753-780
issn 0022-1147
1750-3841
language eng
recordid cdi_proquest_journals_194378080
source Wiley
subjects ALIMENTOS
Biological and medical sciences
CARNE DE POLLO
chicken
CHICKEN MEAT
Cooking
FOOD ANALYSIS
Food industries
Food science
FOODS
Fundamental and applied biological sciences. Psychology
HEAT TREATMENT
Meat and meat product industries
near infrared spectroscopy
Poultry
PRODUIT ALIMENTAIRE
Scientific imaging
Temperature
thermal history
TRAITEMENT THERMIQUE
TRATAMIENTO TERMICO
VIANDE DE POULET
title Evaluating previous thermal treatment of chicken patties by visible/near-infrared spectroscopy
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T18%3A08%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluating%20previous%20thermal%20treatment%20of%20chicken%20patties%20by%20visible/near-infrared%20spectroscopy&rft.jtitle=Journal%20of%20food%20science&rft.au=Chen,%20H.%20(University%20of%20Arkansas,%20Fayetteville,%20AR.)&rft.date=1997-07&rft.volume=62&rft.issue=4&rft.spage=753&rft.epage=780&rft.pages=753-780&rft.issn=0022-1147&rft.eissn=1750-3841&rft.coden=JFDSAZ&rft_id=info:doi/10.1111/j.1365-2621.1997.tb15450.x&rft_dat=%3Cproquest_cross%3E22517213%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c5013-1b80289d6d918e2eaf4c508ca727a382e0fa0fce84f87e60dcc35962c624c0713%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=194378080&rft_id=info:pmid/&rfr_iscdi=true