Model based leak correction of real-time RQ measurement for dynamic controlled atmosphere storage
•A method to correct real-time RQ estimates for leakage was developed.•Leakage correction method is based on a general gas transport model of a cool room.•The leakage of postharvest storage facilities is a pressure driven process.•Leakage correction improves the accuracy of the estimates of the RQ o...
Saved in:
Published in: | Postharvest biology and technology 2018-02, Vol.136, p.31-41 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | •A method to correct real-time RQ estimates for leakage was developed.•Leakage correction method is based on a general gas transport model of a cool room.•The leakage of postharvest storage facilities is a pressure driven process.•Leakage correction improves the accuracy of the estimates of the RQ of stored fruit.
A method was developed to correct real-time measurements of the respiratory quotient (RQ) of pome fruit for gas leakage of a cool room. The method is based on a general leakage model that was simplified by performing sensitivity analysis of the contribution of the pressure driven and concentration driven gas transport terms. The analysis showed that pressure driven leakage was dominant over diffusive leakage. The methodology was validated successfully using an empty storage container at 0.4kPa O2 and 1.3kPa CO2. A sensitivity analysis using virtual storage experiments showed that the error of the RQ estimates with leak correction was 0%, while without leak correction they increased to above 700%. Finally, the validated model was successfully implemented in an automated RQ-DCA control system using ‘Braeburn’ apple fruit (Malus×domestica ‘Braeburn’ 2x). RQ estimates without leakage correction were heavily biased when leakage of atmospheric air into the storage container occurred and would lead to erroneous control of the storage atmosphere composition. With the developed leakage correction, RQ measurements were found to be accurate during decreasing as well as increasing atmospheric air pressure. |
---|---|