Loading…

The performance of EWMA median and CUSUM median control charts for a normal process with measurement errors

Measurement error is often occurred in statistical process control. The effect of a linearly covariate error model on the exponentially weighted moving average (EWMA) median and cumulative sum (CUSUM) median charts is investigated. The results indicate that the EWMA median and CUSUM median charts ar...

Full description

Saved in:
Bibliographic Details
Published in:Quality and reliability engineering international 2018-03, Vol.34 (2), p.203-213
Main Authors: Cheng, Xiao‐Bin, Wang, Fu‐Kwun
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Measurement error is often occurred in statistical process control. The effect of a linearly covariate error model on the exponentially weighted moving average (EWMA) median and cumulative sum (CUSUM) median charts is investigated. The results indicate that the EWMA median and CUSUM median charts are significantly affected in the presence of measurement errors. We compared the performance of the EWMA median and CUSUM median charts by using Markov chain method in the average run length and the standard deviation of the run length. We concluded that the CUSUM median chart for small shifts and the EWMA median chart for larger shifts are recommended. Two examples are provided to illustrate the application of the EWMA and CUSUM median charts with measurement errors.
ISSN:0748-8017
1099-1638
DOI:10.1002/qre.2248