Handling input voltage frequency variations in power factor correctors with pre-calculated duty cycles
The use of pre-calculated duty cycles for power factor correction leads to a significant simplification of the design and a reduction of the final cost. There are previous proposals for handling non-nominal conditions such as input voltage or load variations in pre-calculated power factor correction...
Saved in:
Published in: | Electrical engineering 2018-03, Vol.100 (1), p.27-38 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The use of pre-calculated duty cycles for power factor correction leads to a significant simplification of the design and a reduction of the final cost. There are previous proposals for handling non-nominal conditions such as input voltage or load variations in pre-calculated power factor correction. However, there are no proposals for handling input frequency variations for this kind of pre-calculated duty cycles controllers, which have an important impact in the power factor even if they are small variations. This paper measures this impact and includes two alternative solutions to handle the variations of the input frequency. The results show that the introduction of either of these solutions keeps the power factor values over 0.991 and the input current total harmonic distortion below 11.33% for an input frequency range from 48 to 52 Hz. |
---|---|