Loading…

NEW IPSILATERAL BALLOON OCCLUSION TECHNIQUE FOR PERCUTANEOUS CLOSURE AFTER TRANSFEMORAL AORTIC VALVE REPLACEMENT AND COMPARISON WITH ROUTINE CROSSOVER BALLOON OCCLUSION TECHNIQUE

The novel ipsilateral balloon occlusion technique (IBOT) involves passage of a balloon catheter from the ipsilateral superficial femoral artery to enable controlled closure of large-sheath access-site. None of the end points statistically differed between the groups due to small patient population C...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the American College of Cardiology 2018-03, Vol.71 (11), p.A1141-A1141
Main Authors: Goel, Sunny, Siddiqui, Sabah, Agarwal, Chirag, Borgen, Elliot, Shani, Jacob, Frankel, Robert
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The novel ipsilateral balloon occlusion technique (IBOT) involves passage of a balloon catheter from the ipsilateral superficial femoral artery to enable controlled closure of large-sheath access-site. None of the end points statistically differed between the groups due to small patient population Conclusion IBOT for TAVR access site closure is comparable to routine CBOT after transfemoral TAVR and can be used in patients with unfavorable iliac anatomy