Loading…
Comparative Enantiomer-Resolving Ability of Coated and Covalently Immobilized Versions of Two Polysaccharide-Based Chiral Selectors in High-Performance Liquid Chromatography
The separation of enantiomers of over 175 randomly selected chiral acidic, basic, and neutral compounds was studied on 4 polysaccharide-based chiral columns made by coating or covalent attachment of cellulose 3,5-dichlorophenylcarbamate or amylose 3,5-dimethylphenylcarbamate on the surface of silica...
Saved in:
Published in: | Chromatographia 2018-04, Vol.81 (4), p.611-621 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c342t-4fb95675f9cc944e93fdcbbd471533413c1f31cf867783053a27109447f005b23 |
---|---|
cites | cdi_FETCH-LOGICAL-c342t-4fb95675f9cc944e93fdcbbd471533413c1f31cf867783053a27109447f005b23 |
container_end_page | 621 |
container_issue | 4 |
container_start_page | 611 |
container_title | Chromatographia |
container_volume | 81 |
creator | Beridze, Nino Tsutskiridze, Eka Takaishvili, Nino Farkas, Tivadar Chankvetadze, Bezhan |
description | The separation of enantiomers of over 175 randomly selected chiral acidic, basic, and neutral compounds was studied on 4 polysaccharide-based chiral columns made by coating or covalent attachment of cellulose 3,5-dichlorophenylcarbamate or amylose 3,5-dimethylphenylcarbamate on the surface of silica. Triscarbamate derivatives of cellulose or amylose were used for the preparation of coated-type columns, while in the case of covalently immobilized chiral stationary phases, the respective polysaccharides were not completely carbamoylated but only close to triscarbamates. It was found that this minimal difference in the chemical composition of the polysaccharide derivatives resulted in significantly different enantiomer-resolving ability for certain groups of chiral compounds while only marginally different for other chiral analytes. This potential difference between coated- and covalently immobilized versions of the “same” chiral selector must be considered in method development with these columns, as well as in method transfer between them. |
doi_str_mv | 10.1007/s10337-018-3493-5 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2019527290</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2019527290</sourcerecordid><originalsourceid>FETCH-LOGICAL-c342t-4fb95675f9cc944e93fdcbbd471533413c1f31cf867783053a27109447f005b23</originalsourceid><addsrcrecordid>eNp1kc9u3CAQh1GVSt2kfYDekHqm5Y8xyzG10iTSSonatFeEMewS2bABdiP3nfKOwdpKOfU0M5rvN3P4APhM8FeCsfiWCWZMIEzWiDWSIf4OrEhLKCKE0DOwwhhLxNeSfQDnOT_Wkcq2XYGXLk57nXTxRwuvgg7Fx8km9NPmOB592MLL3o--zDA62EVd7AB1GGp71KMNZZzh7TTFhflbV39syj6GvNAPzxHex3HO2pidTn6w6LvOFep2PukR_rKjNSWmDH2AN367Q_c2uZgmHYyFG_908Aub4qRL3Ca9380fwXunx2w__asX4PePq4fuBm3urm-7yw0yrKEFNa6XvBXcSWNk01jJ3GD6fmgE4Yw1hBniGDFu3QqxZpgzTQXBlRQOY95TdgG-nO7uU3w62FzUYzykUF8qionkVFCJK0VOlEkx52Sd2ic_6TQrgtViRZ2sqGpFLVYUrxl6yuTKhq1Nb5f_H3oF5UCSYQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2019527290</pqid></control><display><type>article</type><title>Comparative Enantiomer-Resolving Ability of Coated and Covalently Immobilized Versions of Two Polysaccharide-Based Chiral Selectors in High-Performance Liquid Chromatography</title><source>Springer Nature</source><creator>Beridze, Nino ; Tsutskiridze, Eka ; Takaishvili, Nino ; Farkas, Tivadar ; Chankvetadze, Bezhan</creator><creatorcontrib>Beridze, Nino ; Tsutskiridze, Eka ; Takaishvili, Nino ; Farkas, Tivadar ; Chankvetadze, Bezhan</creatorcontrib><description>The separation of enantiomers of over 175 randomly selected chiral acidic, basic, and neutral compounds was studied on 4 polysaccharide-based chiral columns made by coating or covalent attachment of cellulose 3,5-dichlorophenylcarbamate or amylose 3,5-dimethylphenylcarbamate on the surface of silica. Triscarbamate derivatives of cellulose or amylose were used for the preparation of coated-type columns, while in the case of covalently immobilized chiral stationary phases, the respective polysaccharides were not completely carbamoylated but only close to triscarbamates. It was found that this minimal difference in the chemical composition of the polysaccharide derivatives resulted in significantly different enantiomer-resolving ability for certain groups of chiral compounds while only marginally different for other chiral analytes. This potential difference between coated- and covalently immobilized versions of the “same” chiral selector must be considered in method development with these columns, as well as in method transfer between them.</description><identifier>ISSN: 0009-5893</identifier><identifier>EISSN: 1612-1112</identifier><identifier>DOI: 10.1007/s10337-018-3493-5</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Analytical Chemistry ; Cellulose ; Chemistry ; Chemistry and Materials Science ; Chromatography ; Coating ; Covalence ; Derivatives ; Enantiomers ; High performance liquid chromatography ; Laboratory Medicine ; Original ; Pharmacy ; Polysaccharides ; Proteomics ; Selectors ; Silicon dioxide</subject><ispartof>Chromatographia, 2018-04, Vol.81 (4), p.611-621</ispartof><rights>Springer-Verlag GmbH Germany, part of Springer Nature 2018</rights><rights>Copyright Springer Science & Business Media 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c342t-4fb95675f9cc944e93fdcbbd471533413c1f31cf867783053a27109447f005b23</citedby><cites>FETCH-LOGICAL-c342t-4fb95675f9cc944e93fdcbbd471533413c1f31cf867783053a27109447f005b23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Beridze, Nino</creatorcontrib><creatorcontrib>Tsutskiridze, Eka</creatorcontrib><creatorcontrib>Takaishvili, Nino</creatorcontrib><creatorcontrib>Farkas, Tivadar</creatorcontrib><creatorcontrib>Chankvetadze, Bezhan</creatorcontrib><title>Comparative Enantiomer-Resolving Ability of Coated and Covalently Immobilized Versions of Two Polysaccharide-Based Chiral Selectors in High-Performance Liquid Chromatography</title><title>Chromatographia</title><addtitle>Chromatographia</addtitle><description>The separation of enantiomers of over 175 randomly selected chiral acidic, basic, and neutral compounds was studied on 4 polysaccharide-based chiral columns made by coating or covalent attachment of cellulose 3,5-dichlorophenylcarbamate or amylose 3,5-dimethylphenylcarbamate on the surface of silica. Triscarbamate derivatives of cellulose or amylose were used for the preparation of coated-type columns, while in the case of covalently immobilized chiral stationary phases, the respective polysaccharides were not completely carbamoylated but only close to triscarbamates. It was found that this minimal difference in the chemical composition of the polysaccharide derivatives resulted in significantly different enantiomer-resolving ability for certain groups of chiral compounds while only marginally different for other chiral analytes. This potential difference between coated- and covalently immobilized versions of the “same” chiral selector must be considered in method development with these columns, as well as in method transfer between them.</description><subject>Analytical Chemistry</subject><subject>Cellulose</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Chromatography</subject><subject>Coating</subject><subject>Covalence</subject><subject>Derivatives</subject><subject>Enantiomers</subject><subject>High performance liquid chromatography</subject><subject>Laboratory Medicine</subject><subject>Original</subject><subject>Pharmacy</subject><subject>Polysaccharides</subject><subject>Proteomics</subject><subject>Selectors</subject><subject>Silicon dioxide</subject><issn>0009-5893</issn><issn>1612-1112</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp1kc9u3CAQh1GVSt2kfYDekHqm5Y8xyzG10iTSSonatFeEMewS2bABdiP3nfKOwdpKOfU0M5rvN3P4APhM8FeCsfiWCWZMIEzWiDWSIf4OrEhLKCKE0DOwwhhLxNeSfQDnOT_Wkcq2XYGXLk57nXTxRwuvgg7Fx8km9NPmOB592MLL3o--zDA62EVd7AB1GGp71KMNZZzh7TTFhflbV39syj6GvNAPzxHex3HO2pidTn6w6LvOFep2PukR_rKjNSWmDH2AN367Q_c2uZgmHYyFG_908Aub4qRL3Ca9380fwXunx2w__asX4PePq4fuBm3urm-7yw0yrKEFNa6XvBXcSWNk01jJ3GD6fmgE4Yw1hBniGDFu3QqxZpgzTQXBlRQOY95TdgG-nO7uU3w62FzUYzykUF8qionkVFCJK0VOlEkx52Sd2ic_6TQrgtViRZ2sqGpFLVYUrxl6yuTKhq1Nb5f_H3oF5UCSYQ</recordid><startdate>20180401</startdate><enddate>20180401</enddate><creator>Beridze, Nino</creator><creator>Tsutskiridze, Eka</creator><creator>Takaishvili, Nino</creator><creator>Farkas, Tivadar</creator><creator>Chankvetadze, Bezhan</creator><general>Springer Berlin Heidelberg</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20180401</creationdate><title>Comparative Enantiomer-Resolving Ability of Coated and Covalently Immobilized Versions of Two Polysaccharide-Based Chiral Selectors in High-Performance Liquid Chromatography</title><author>Beridze, Nino ; Tsutskiridze, Eka ; Takaishvili, Nino ; Farkas, Tivadar ; Chankvetadze, Bezhan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c342t-4fb95675f9cc944e93fdcbbd471533413c1f31cf867783053a27109447f005b23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Analytical Chemistry</topic><topic>Cellulose</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Chromatography</topic><topic>Coating</topic><topic>Covalence</topic><topic>Derivatives</topic><topic>Enantiomers</topic><topic>High performance liquid chromatography</topic><topic>Laboratory Medicine</topic><topic>Original</topic><topic>Pharmacy</topic><topic>Polysaccharides</topic><topic>Proteomics</topic><topic>Selectors</topic><topic>Silicon dioxide</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Beridze, Nino</creatorcontrib><creatorcontrib>Tsutskiridze, Eka</creatorcontrib><creatorcontrib>Takaishvili, Nino</creatorcontrib><creatorcontrib>Farkas, Tivadar</creatorcontrib><creatorcontrib>Chankvetadze, Bezhan</creatorcontrib><collection>CrossRef</collection><jtitle>Chromatographia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Beridze, Nino</au><au>Tsutskiridze, Eka</au><au>Takaishvili, Nino</au><au>Farkas, Tivadar</au><au>Chankvetadze, Bezhan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparative Enantiomer-Resolving Ability of Coated and Covalently Immobilized Versions of Two Polysaccharide-Based Chiral Selectors in High-Performance Liquid Chromatography</atitle><jtitle>Chromatographia</jtitle><stitle>Chromatographia</stitle><date>2018-04-01</date><risdate>2018</risdate><volume>81</volume><issue>4</issue><spage>611</spage><epage>621</epage><pages>611-621</pages><issn>0009-5893</issn><eissn>1612-1112</eissn><abstract>The separation of enantiomers of over 175 randomly selected chiral acidic, basic, and neutral compounds was studied on 4 polysaccharide-based chiral columns made by coating or covalent attachment of cellulose 3,5-dichlorophenylcarbamate or amylose 3,5-dimethylphenylcarbamate on the surface of silica. Triscarbamate derivatives of cellulose or amylose were used for the preparation of coated-type columns, while in the case of covalently immobilized chiral stationary phases, the respective polysaccharides were not completely carbamoylated but only close to triscarbamates. It was found that this minimal difference in the chemical composition of the polysaccharide derivatives resulted in significantly different enantiomer-resolving ability for certain groups of chiral compounds while only marginally different for other chiral analytes. This potential difference between coated- and covalently immobilized versions of the “same” chiral selector must be considered in method development with these columns, as well as in method transfer between them.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><doi>10.1007/s10337-018-3493-5</doi><tpages>11</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0009-5893 |
ispartof | Chromatographia, 2018-04, Vol.81 (4), p.611-621 |
issn | 0009-5893 1612-1112 |
language | eng |
recordid | cdi_proquest_journals_2019527290 |
source | Springer Nature |
subjects | Analytical Chemistry Cellulose Chemistry Chemistry and Materials Science Chromatography Coating Covalence Derivatives Enantiomers High performance liquid chromatography Laboratory Medicine Original Pharmacy Polysaccharides Proteomics Selectors Silicon dioxide |
title | Comparative Enantiomer-Resolving Ability of Coated and Covalently Immobilized Versions of Two Polysaccharide-Based Chiral Selectors in High-Performance Liquid Chromatography |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T08%3A21%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparative%20Enantiomer-Resolving%20Ability%20of%20Coated%20and%20Covalently%20Immobilized%20Versions%20of%20Two%20Polysaccharide-Based%20Chiral%20Selectors%20in%20High-Performance%20Liquid%20Chromatography&rft.jtitle=Chromatographia&rft.au=Beridze,%20Nino&rft.date=2018-04-01&rft.volume=81&rft.issue=4&rft.spage=611&rft.epage=621&rft.pages=611-621&rft.issn=0009-5893&rft.eissn=1612-1112&rft_id=info:doi/10.1007/s10337-018-3493-5&rft_dat=%3Cproquest_cross%3E2019527290%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c342t-4fb95675f9cc944e93fdcbbd471533413c1f31cf867783053a27109447f005b23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2019527290&rft_id=info:pmid/&rfr_iscdi=true |