Introduction of filtered containment venting system experimental facility in KAERI and results of aerosol test
•Korean type FCVS integration test facility was introduced.•Aerosol removal test was conducted and evaluate the FCVS performance with DF.•Aerosol properties were analyzed at the inlet and outlet of the FCVS. Filtered containment venting system (FCVS) has been developed since 2014 in Korea, and an in...
Saved in:
Published in: | Nuclear engineering and design 2018-01, Vol.326, p.344-353 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c380t-3ebb0ba34d2748ec08c004a26179d3e9df6f28f3c16c2c91df6fec3f243788263 |
---|---|
cites | cdi_FETCH-LOGICAL-c380t-3ebb0ba34d2748ec08c004a26179d3e9df6f28f3c16c2c91df6fec3f243788263 |
container_end_page | 353 |
container_issue | |
container_start_page | 344 |
container_title | Nuclear engineering and design |
container_volume | 326 |
creator | Kim, Sung Il Lee, Jae Bong Jung, Jae Hoon Ha, Kwang Soon Kim, Hwan Yeol Song, JinHo |
description | •Korean type FCVS integration test facility was introduced.•Aerosol removal test was conducted and evaluate the FCVS performance with DF.•Aerosol properties were analyzed at the inlet and outlet of the FCVS.
Filtered containment venting system (FCVS) has been developed since 2014 in Korea, and an integration performance verification test has been performed at the Korea Atomic Energy Research Institute (KAERI). The experimental facility was named ARIEL: Aerosol Removal & Iodine Elimination (ARIEL). The ARIEL facility is composed of four major parts; venturi scrubber, cyclone, metal fiber filter (MFF), and molecular sieve (MS). In addition, a generation and sampling system of aerosol and iodine were equipped to the system. In this study, the current status of the FCVS experimental facility in KAERI is introduced along with a description of the aerosol generation and sampling system. Aerosol removal test results, performed 7 bar abs. with non-condensable gas, is also presented. The analysis of the results was conducted with filter and aerosol measurement equipment, and is included in the study. |
doi_str_mv | 10.1016/j.nucengdes.2017.11.036 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2044643561</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0029549317305526</els_id><sourcerecordid>2044643561</sourcerecordid><originalsourceid>FETCH-LOGICAL-c380t-3ebb0ba34d2748ec08c004a26179d3e9df6f28f3c16c2c91df6fec3f243788263</originalsourceid><addsrcrecordid>eNqFUE1LAzEQDaJgrf4GA553zcd2P46lVC0WBFHwFtJkUlK2SU2yYv-9WSpencMMw8y8N-8hdEtJSQmt73elGxS4rYZYMkKbktKS8PoMTWjbsKKZdR_naEII64pZ1fFLdBXjjozRsQlyK5eC14NK1jvsDTa2TxBAY-VdktbtwSX8lZN1WxyPMcEew_cBgh0nssdGKtvbdMTW4ef58nWFpdM4QBz6FEdECcFH3-MEMV2jCyP7CDe_dYreH5Zvi6di_fK4WszXheItSQWHzYZsJK80a6oWFGkVIZVkNW06zaHTpjasNVzRWjHV0bEHxQ2reNO2rOZTdHfCPQT_OWRisfNDcJlSMFJVdcVnNc1bzWlL5Q9jACMOWZYMR0GJGM0VO_FnrhjNFZSKbG6-nJ8uIYv4shBEVBacAm0DqCS0t_9i_AAWhol6</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2044643561</pqid></control><display><type>article</type><title>Introduction of filtered containment venting system experimental facility in KAERI and results of aerosol test</title><source>Elsevier</source><creator>Kim, Sung Il ; Lee, Jae Bong ; Jung, Jae Hoon ; Ha, Kwang Soon ; Kim, Hwan Yeol ; Song, JinHo</creator><creatorcontrib>Kim, Sung Il ; Lee, Jae Bong ; Jung, Jae Hoon ; Ha, Kwang Soon ; Kim, Hwan Yeol ; Song, JinHo</creatorcontrib><description>•Korean type FCVS integration test facility was introduced.•Aerosol removal test was conducted and evaluate the FCVS performance with DF.•Aerosol properties were analyzed at the inlet and outlet of the FCVS.
Filtered containment venting system (FCVS) has been developed since 2014 in Korea, and an integration performance verification test has been performed at the Korea Atomic Energy Research Institute (KAERI). The experimental facility was named ARIEL: Aerosol Removal & Iodine Elimination (ARIEL). The ARIEL facility is composed of four major parts; venturi scrubber, cyclone, metal fiber filter (MFF), and molecular sieve (MS). In addition, a generation and sampling system of aerosol and iodine were equipped to the system. In this study, the current status of the FCVS experimental facility in KAERI is introduced along with a description of the aerosol generation and sampling system. Aerosol removal test results, performed 7 bar abs. with non-condensable gas, is also presented. The analysis of the results was conducted with filter and aerosol measurement equipment, and is included in the study.</description><identifier>ISSN: 0029-5493</identifier><identifier>EISSN: 1872-759X</identifier><identifier>DOI: 10.1016/j.nucengdes.2017.11.036</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Aerosols ; Containment ; Cyclones ; Decontamination factor (DF) ; Energy research ; Filtered containment venting system (FCVS) ; Fission product ; Iodine ; Measurement ; Metal fibers ; Molecular chains ; Molecular sieves ; Nuclear energy ; Pool scrubbing ; Radioactive aerosol ; Sampling ; Severe accident ; Studies ; Venting systems ; Venturi scrubbers</subject><ispartof>Nuclear engineering and design, 2018-01, Vol.326, p.344-353</ispartof><rights>2017 Elsevier B.V.</rights><rights>Copyright Elsevier BV Jan 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c380t-3ebb0ba34d2748ec08c004a26179d3e9df6f28f3c16c2c91df6fec3f243788263</citedby><cites>FETCH-LOGICAL-c380t-3ebb0ba34d2748ec08c004a26179d3e9df6f28f3c16c2c91df6fec3f243788263</cites><orcidid>0000-0002-9860-8414</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Kim, Sung Il</creatorcontrib><creatorcontrib>Lee, Jae Bong</creatorcontrib><creatorcontrib>Jung, Jae Hoon</creatorcontrib><creatorcontrib>Ha, Kwang Soon</creatorcontrib><creatorcontrib>Kim, Hwan Yeol</creatorcontrib><creatorcontrib>Song, JinHo</creatorcontrib><title>Introduction of filtered containment venting system experimental facility in KAERI and results of aerosol test</title><title>Nuclear engineering and design</title><description>•Korean type FCVS integration test facility was introduced.•Aerosol removal test was conducted and evaluate the FCVS performance with DF.•Aerosol properties were analyzed at the inlet and outlet of the FCVS.
Filtered containment venting system (FCVS) has been developed since 2014 in Korea, and an integration performance verification test has been performed at the Korea Atomic Energy Research Institute (KAERI). The experimental facility was named ARIEL: Aerosol Removal & Iodine Elimination (ARIEL). The ARIEL facility is composed of four major parts; venturi scrubber, cyclone, metal fiber filter (MFF), and molecular sieve (MS). In addition, a generation and sampling system of aerosol and iodine were equipped to the system. In this study, the current status of the FCVS experimental facility in KAERI is introduced along with a description of the aerosol generation and sampling system. Aerosol removal test results, performed 7 bar abs. with non-condensable gas, is also presented. The analysis of the results was conducted with filter and aerosol measurement equipment, and is included in the study.</description><subject>Aerosols</subject><subject>Containment</subject><subject>Cyclones</subject><subject>Decontamination factor (DF)</subject><subject>Energy research</subject><subject>Filtered containment venting system (FCVS)</subject><subject>Fission product</subject><subject>Iodine</subject><subject>Measurement</subject><subject>Metal fibers</subject><subject>Molecular chains</subject><subject>Molecular sieves</subject><subject>Nuclear energy</subject><subject>Pool scrubbing</subject><subject>Radioactive aerosol</subject><subject>Sampling</subject><subject>Severe accident</subject><subject>Studies</subject><subject>Venting systems</subject><subject>Venturi scrubbers</subject><issn>0029-5493</issn><issn>1872-759X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqFUE1LAzEQDaJgrf4GA553zcd2P46lVC0WBFHwFtJkUlK2SU2yYv-9WSpencMMw8y8N-8hdEtJSQmt73elGxS4rYZYMkKbktKS8PoMTWjbsKKZdR_naEII64pZ1fFLdBXjjozRsQlyK5eC14NK1jvsDTa2TxBAY-VdktbtwSX8lZN1WxyPMcEew_cBgh0nssdGKtvbdMTW4ef58nWFpdM4QBz6FEdECcFH3-MEMV2jCyP7CDe_dYreH5Zvi6di_fK4WszXheItSQWHzYZsJK80a6oWFGkVIZVkNW06zaHTpjasNVzRWjHV0bEHxQ2reNO2rOZTdHfCPQT_OWRisfNDcJlSMFJVdcVnNc1bzWlL5Q9jACMOWZYMR0GJGM0VO_FnrhjNFZSKbG6-nJ8uIYv4shBEVBacAm0DqCS0t_9i_AAWhol6</recordid><startdate>201801</startdate><enddate>201801</enddate><creator>Kim, Sung Il</creator><creator>Lee, Jae Bong</creator><creator>Jung, Jae Hoon</creator><creator>Ha, Kwang Soon</creator><creator>Kim, Hwan Yeol</creator><creator>Song, JinHo</creator><general>Elsevier B.V</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7ST</scope><scope>7TB</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope><scope>SOI</scope><orcidid>https://orcid.org/0000-0002-9860-8414</orcidid></search><sort><creationdate>201801</creationdate><title>Introduction of filtered containment venting system experimental facility in KAERI and results of aerosol test</title><author>Kim, Sung Il ; Lee, Jae Bong ; Jung, Jae Hoon ; Ha, Kwang Soon ; Kim, Hwan Yeol ; Song, JinHo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c380t-3ebb0ba34d2748ec08c004a26179d3e9df6f28f3c16c2c91df6fec3f243788263</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Aerosols</topic><topic>Containment</topic><topic>Cyclones</topic><topic>Decontamination factor (DF)</topic><topic>Energy research</topic><topic>Filtered containment venting system (FCVS)</topic><topic>Fission product</topic><topic>Iodine</topic><topic>Measurement</topic><topic>Metal fibers</topic><topic>Molecular chains</topic><topic>Molecular sieves</topic><topic>Nuclear energy</topic><topic>Pool scrubbing</topic><topic>Radioactive aerosol</topic><topic>Sampling</topic><topic>Severe accident</topic><topic>Studies</topic><topic>Venting systems</topic><topic>Venturi scrubbers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kim, Sung Il</creatorcontrib><creatorcontrib>Lee, Jae Bong</creatorcontrib><creatorcontrib>Jung, Jae Hoon</creatorcontrib><creatorcontrib>Ha, Kwang Soon</creatorcontrib><creatorcontrib>Kim, Hwan Yeol</creatorcontrib><creatorcontrib>Song, JinHo</creatorcontrib><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Environment Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Environment Abstracts</collection><jtitle>Nuclear engineering and design</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kim, Sung Il</au><au>Lee, Jae Bong</au><au>Jung, Jae Hoon</au><au>Ha, Kwang Soon</au><au>Kim, Hwan Yeol</au><au>Song, JinHo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Introduction of filtered containment venting system experimental facility in KAERI and results of aerosol test</atitle><jtitle>Nuclear engineering and design</jtitle><date>2018-01</date><risdate>2018</risdate><volume>326</volume><spage>344</spage><epage>353</epage><pages>344-353</pages><issn>0029-5493</issn><eissn>1872-759X</eissn><abstract>•Korean type FCVS integration test facility was introduced.•Aerosol removal test was conducted and evaluate the FCVS performance with DF.•Aerosol properties were analyzed at the inlet and outlet of the FCVS.
Filtered containment venting system (FCVS) has been developed since 2014 in Korea, and an integration performance verification test has been performed at the Korea Atomic Energy Research Institute (KAERI). The experimental facility was named ARIEL: Aerosol Removal & Iodine Elimination (ARIEL). The ARIEL facility is composed of four major parts; venturi scrubber, cyclone, metal fiber filter (MFF), and molecular sieve (MS). In addition, a generation and sampling system of aerosol and iodine were equipped to the system. In this study, the current status of the FCVS experimental facility in KAERI is introduced along with a description of the aerosol generation and sampling system. Aerosol removal test results, performed 7 bar abs. with non-condensable gas, is also presented. The analysis of the results was conducted with filter and aerosol measurement equipment, and is included in the study.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.nucengdes.2017.11.036</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0002-9860-8414</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0029-5493 |
ispartof | Nuclear engineering and design, 2018-01, Vol.326, p.344-353 |
issn | 0029-5493 1872-759X |
language | eng |
recordid | cdi_proquest_journals_2044643561 |
source | Elsevier |
subjects | Aerosols Containment Cyclones Decontamination factor (DF) Energy research Filtered containment venting system (FCVS) Fission product Iodine Measurement Metal fibers Molecular chains Molecular sieves Nuclear energy Pool scrubbing Radioactive aerosol Sampling Severe accident Studies Venting systems Venturi scrubbers |
title | Introduction of filtered containment venting system experimental facility in KAERI and results of aerosol test |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T00%3A55%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Introduction%20of%20filtered%20containment%20venting%20system%20experimental%20facility%20in%20KAERI%20and%20results%20of%20aerosol%20test&rft.jtitle=Nuclear%20engineering%20and%20design&rft.au=Kim,%20Sung%20Il&rft.date=2018-01&rft.volume=326&rft.spage=344&rft.epage=353&rft.pages=344-353&rft.issn=0029-5493&rft.eissn=1872-759X&rft_id=info:doi/10.1016/j.nucengdes.2017.11.036&rft_dat=%3Cproquest_cross%3E2044643561%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c380t-3ebb0ba34d2748ec08c004a26179d3e9df6f28f3c16c2c91df6fec3f243788263%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2044643561&rft_id=info:pmid/&rfr_iscdi=true |