Remote Identification of Liquids in a Dielectric Container Using Millimeter Waves. 2. Linear Scanning

The results of experimental studies showing the applicability of short-range radar in the millimeter wavelength range for remote identification of explosive liquids in closed dielectric containers are presented. This study presents radiometric study of hazardous liquids based on an example of gasoli...

Full description

Saved in:
Bibliographic Details
Published in:Radioelectronics and communications systems 2018, Vol.61 (4), p.157-167
Main Authors: Pavlyuchenko, A. V., Loshitskiy, P. P., Shelengovskiy, A. I., Babenko, V. V.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The results of experimental studies showing the applicability of short-range radar in the millimeter wavelength range for remote identification of explosive liquids in closed dielectric containers are presented. This study presents radiometric study of hazardous liquids based on an example of gasolines and diesel fuels. It has been shown experimentally that radiometric studies allow remote studies and object identification at distances of up to several meters. The variety of physical and chemical properties of liquid fuels does not allow their identification using the measurement results of only the permittivity and loss tangent from one measurement in one frequency range. The use of a thermal portrait of liquid fuels in closed dielectric containers for their identification is more illustrative and informative. The dependence of the spatial temperature portrait of the container with liquid on the polarization of the received signal is experimentally shown. The use of different polarizations of the received signal and the difference in the spatial temperature portraits of the liquid in the container provide additional information in order to increase the probability of correct identification of the liquid. Thermal portraits obtained with linear scanning for gasolines of different manufacturers differ more strongly, in comparison with thermal portraits of diesel fuels. Due to the modification of the measuring system, the total time for scanning and obtaining the output experimental data is 42 s. The standard deviation of the obtained experimental data did not exceed 3.6%.
ISSN:0735-2727
1934-8061
DOI:10.3103/S0735272718040039