Low temperature dissolution flowsheet for Pu metal
The Savannah River National Laboratory was requested to develop a Pu metal dissolution flowsheet at two reduced temperature ranges for implementation in the Savannah River Site H-Canyon facility. The dissolution and H 2 generation rates during Pu metal dissolution were investigated using a dissolvin...
Saved in:
Published in: | Separation science and technology 2018-08, Vol.53 (12), p.1874-1884 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The Savannah River National Laboratory was requested to develop a Pu metal dissolution flowsheet at two reduced temperature ranges for implementation in the Savannah River Site H-Canyon facility. The dissolution and H
2
generation rates during Pu metal dissolution were investigated using a dissolving solution at ambient temperature (20-30°C) and for an intermediate temperature of 50-60°C. The Pu metal dissolution rate measured at 57°C was approximately 20 times slower than at boiling (112-116°C). The dissolution rate at ambient temperature (24°C) was approximately 80 times slower than the dissolution rate at boiling. Hydrogen concentrations were less than detectable ( |
---|---|
ISSN: | 0149-6395 1520-5754 |
DOI: | 10.1080/01496395.2016.1271340 |