Optimum Phase Shift in the Self-Oscillating Loop for Piezoelectric-Transformer-Based Power Converters
A new method is implemented in designing of self-oscillating loop for driving piezoelectric transformers (PT). The implemented method is based on combining both analog and digital control systems. Digitally controlled time delay through the self-oscillating loop results in very precise frequency con...
Saved in:
Published in: | IEEE transactions on power electronics 2018-09, Vol.33 (9), p.8101-8109 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A new method is implemented in designing of self-oscillating loop for driving piezoelectric transformers (PT). The implemented method is based on combining both analog and digital control systems. Digitally controlled time delay through the self-oscillating loop results in very precise frequency control and ensures optimum operation of the PT in terms of gain and efficiency. Time delay is implemented digitally for the first time through a 16-b digital-to-analog converter in the self-oscillating loop. The new design of the delay circuit provides 45-ps time resolution, enabling fine-grained control of phase in the self-oscillating loop. This allows the control loop to dynamically follow frequency changes of the transformer in each resonant cycle. Ultimately, by selecting the optimum phase shift, maximum efficiency under the load and temperature condition is achievable. |
---|---|