Loading…

The iLocater cryostat: design and thermal control strategy for precision radial velocity measurements

The current generation of precision radial velocity (RV) spectrographs are seeing-limited instruments. In order to achieve high spectral resolution on 8m class telescopes, these spectrographs require large optics and in turn, large instrument volumes. Achieving milli-Kelvin thermal stability for the...

Full description

Saved in:
Bibliographic Details
Published in:arXiv.org 2016-09
Main Authors: Crass, Jonathan, Fantano, Louis G, Hearty, Frederick R, Crepp, Justin R, Nelson, Matthew J, Wall, Sheila M, Cavalieri, David A, Koca, Corina, King, David L, Reynolds, Robert O, Stapelfeldt, Karl R
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The current generation of precision radial velocity (RV) spectrographs are seeing-limited instruments. In order to achieve high spectral resolution on 8m class telescopes, these spectrographs require large optics and in turn, large instrument volumes. Achieving milli-Kelvin thermal stability for these systems is challenging but is vital in order to obtain a single measurement RV precision of better than 1m/s. This precision is crucial to study Earth-like exoplanets within the habitable zone. iLocater is a next generation RV instrument being developed for the Large Binocular Telescope. Unlike seeing-limited RV instruments, iLocater uses adaptive optics (AO) to inject a diffraction-limited beam into single-mode fibers. These fibers illuminate the instrument spectrograph, facilitating a diffraction-limited design and a small instrument volume compared to present-day instruments. This enables intrinsic instrument stability and facilitates precision thermal control. We present the current design of the iLocater cryostat which houses the instrument spectrograph and the strategy for its thermal control. The spectrograph is situated within a pair of radiation shields mounted inside an MLI lined vacuum chamber. The outer radiation shield is actively controlled to maintain instrument stability at the sub-mK level and minimize effects of thermal changes from the external environment. An inner shield passively dampens any residual temperature fluctuations and is radiatively coupled to the optical board. To provide intrinsic stability, the optical board and optic mounts will be made from Invar and cooled to 58K to benefit from a zero coefficient of thermal expansion (CTE) value at this temperature. Combined, the small footprint of the instrument spectrograph, the use of Invar, and precision thermal control will allow long-term sub-milliKelvin stability to facilitate precision RV measurements.
ISSN:2331-8422
DOI:10.48550/arxiv.1609.04411