Loading…
Strongly aligned and oriented molecular samples at a kHz repetition rate
We demonstrate strong adiabatic laser alignment and mixed-field orientation at kHz repetition rates. We observe degrees of alignment as large as cos\Theta=0.94 at 1 kHz operation for iodobenzene. The experimental setup consist of a kHz laser system simultaneously producing pulses of 30 fs (1.3 mJ) a...
Saved in:
Published in: | arXiv.org 2013-05 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | |
container_start_page | |
container_title | arXiv.org |
container_volume | |
creator | Trippel, Sebastian Mullins, Terry Müller, Nele L M Kienitz, Jens S Długołecki, Karol Küpper, Jochen |
description | We demonstrate strong adiabatic laser alignment and mixed-field orientation at kHz repetition rates. We observe degrees of alignment as large as cos\Theta=0.94 at 1 kHz operation for iodobenzene. The experimental setup consist of a kHz laser system simultaneously producing pulses of 30 fs (1.3 mJ) and 450 ps (9 mJ). A cold 1 K state-selected molecular beam is produced at the same rate by appropriate operation of an Even-Lavie valve. Quantum state selection has been obtained using an electrostatic deflector. A camera and data acquisition system records and analyzes the images on a single-shot basis. The system is capable of producing, controlling (translation and rotation) and analyzing cold molecular beams at kHz repetition rates and is, therefore, ideally suited for the recording of ultrafast dynamics in so-called "molecular movies". |
doi_str_mv | 10.48550/arxiv.1301.1826 |
format | article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2086082857</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2086082857</sourcerecordid><originalsourceid>FETCH-LOGICAL-a517-49e3cf025eec6bffe91cc76003fdea8ff30e17a5a681b8f47fac1841dbfcd8643</originalsourceid><addsrcrecordid>eNotjc9LwzAYQIMgOObuHgOeW_O72VGGWmHgwd3H1_TL6MzSmqSi_vUO3OnxLu8RcsdZrazW7AHS9_BVc8l4za0wV2QhpOSVVULckFXOR8aYMI3QWi5I-17SGA_hh0IYDhF7CrGnYxowlrOcxoBuDpBohtMUMFMoFOhH-0sTTliGMoyRJih4S649hIyrC5dk9_y027TV9u3ldfO4rUDzplJrlM4zoRGd6bzHNXeuMYxJ3yNY7yVD3oAGY3lnvWo8OG4V7zvvemuUXJL7_-yUxs8Zc9kfxznF83EvmDXMCqsb-QdyCU7T</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2086082857</pqid></control><display><type>article</type><title>Strongly aligned and oriented molecular samples at a kHz repetition rate</title><source>Publicly Available Content Database</source><creator>Trippel, Sebastian ; Mullins, Terry ; Müller, Nele L M ; Kienitz, Jens S ; Długołecki, Karol ; Küpper, Jochen</creator><creatorcontrib>Trippel, Sebastian ; Mullins, Terry ; Müller, Nele L M ; Kienitz, Jens S ; Długołecki, Karol ; Küpper, Jochen</creatorcontrib><description>We demonstrate strong adiabatic laser alignment and mixed-field orientation at kHz repetition rates. We observe degrees of alignment as large as cos\Theta=0.94 at 1 kHz operation for iodobenzene. The experimental setup consist of a kHz laser system simultaneously producing pulses of 30 fs (1.3 mJ) and 450 ps (9 mJ). A cold 1 K state-selected molecular beam is produced at the same rate by appropriate operation of an Even-Lavie valve. Quantum state selection has been obtained using an electrostatic deflector. A camera and data acquisition system records and analyzes the images on a single-shot basis. The system is capable of producing, controlling (translation and rotation) and analyzing cold molecular beams at kHz repetition rates and is, therefore, ideally suited for the recording of ultrafast dynamics in so-called "molecular movies".</description><identifier>EISSN: 2331-8422</identifier><identifier>DOI: 10.48550/arxiv.1301.1826</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Alignment ; Image acquisition ; Molecular beams ; Recording ; Repetition</subject><ispartof>arXiv.org, 2013-05</ispartof><rights>2013. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2086082857?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>780,784,25751,27923,37010,44588</link.rule.ids></links><search><creatorcontrib>Trippel, Sebastian</creatorcontrib><creatorcontrib>Mullins, Terry</creatorcontrib><creatorcontrib>Müller, Nele L M</creatorcontrib><creatorcontrib>Kienitz, Jens S</creatorcontrib><creatorcontrib>Długołecki, Karol</creatorcontrib><creatorcontrib>Küpper, Jochen</creatorcontrib><title>Strongly aligned and oriented molecular samples at a kHz repetition rate</title><title>arXiv.org</title><description>We demonstrate strong adiabatic laser alignment and mixed-field orientation at kHz repetition rates. We observe degrees of alignment as large as cos\Theta=0.94 at 1 kHz operation for iodobenzene. The experimental setup consist of a kHz laser system simultaneously producing pulses of 30 fs (1.3 mJ) and 450 ps (9 mJ). A cold 1 K state-selected molecular beam is produced at the same rate by appropriate operation of an Even-Lavie valve. Quantum state selection has been obtained using an electrostatic deflector. A camera and data acquisition system records and analyzes the images on a single-shot basis. The system is capable of producing, controlling (translation and rotation) and analyzing cold molecular beams at kHz repetition rates and is, therefore, ideally suited for the recording of ultrafast dynamics in so-called "molecular movies".</description><subject>Alignment</subject><subject>Image acquisition</subject><subject>Molecular beams</subject><subject>Recording</subject><subject>Repetition</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNotjc9LwzAYQIMgOObuHgOeW_O72VGGWmHgwd3H1_TL6MzSmqSi_vUO3OnxLu8RcsdZrazW7AHS9_BVc8l4za0wV2QhpOSVVULckFXOR8aYMI3QWi5I-17SGA_hh0IYDhF7CrGnYxowlrOcxoBuDpBohtMUMFMoFOhH-0sTTliGMoyRJih4S649hIyrC5dk9_y027TV9u3ldfO4rUDzplJrlM4zoRGd6bzHNXeuMYxJ3yNY7yVD3oAGY3lnvWo8OG4V7zvvemuUXJL7_-yUxs8Zc9kfxznF83EvmDXMCqsb-QdyCU7T</recordid><startdate>20130523</startdate><enddate>20130523</enddate><creator>Trippel, Sebastian</creator><creator>Mullins, Terry</creator><creator>Müller, Nele L M</creator><creator>Kienitz, Jens S</creator><creator>Długołecki, Karol</creator><creator>Küpper, Jochen</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20130523</creationdate><title>Strongly aligned and oriented molecular samples at a kHz repetition rate</title><author>Trippel, Sebastian ; Mullins, Terry ; Müller, Nele L M ; Kienitz, Jens S ; Długołecki, Karol ; Küpper, Jochen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a517-49e3cf025eec6bffe91cc76003fdea8ff30e17a5a681b8f47fac1841dbfcd8643</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Alignment</topic><topic>Image acquisition</topic><topic>Molecular beams</topic><topic>Recording</topic><topic>Repetition</topic><toplevel>online_resources</toplevel><creatorcontrib>Trippel, Sebastian</creatorcontrib><creatorcontrib>Mullins, Terry</creatorcontrib><creatorcontrib>Müller, Nele L M</creatorcontrib><creatorcontrib>Kienitz, Jens S</creatorcontrib><creatorcontrib>Długołecki, Karol</creatorcontrib><creatorcontrib>Küpper, Jochen</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>arXiv.org</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Trippel, Sebastian</au><au>Mullins, Terry</au><au>Müller, Nele L M</au><au>Kienitz, Jens S</au><au>Długołecki, Karol</au><au>Küpper, Jochen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Strongly aligned and oriented molecular samples at a kHz repetition rate</atitle><jtitle>arXiv.org</jtitle><date>2013-05-23</date><risdate>2013</risdate><eissn>2331-8422</eissn><abstract>We demonstrate strong adiabatic laser alignment and mixed-field orientation at kHz repetition rates. We observe degrees of alignment as large as cos\Theta=0.94 at 1 kHz operation for iodobenzene. The experimental setup consist of a kHz laser system simultaneously producing pulses of 30 fs (1.3 mJ) and 450 ps (9 mJ). A cold 1 K state-selected molecular beam is produced at the same rate by appropriate operation of an Even-Lavie valve. Quantum state selection has been obtained using an electrostatic deflector. A camera and data acquisition system records and analyzes the images on a single-shot basis. The system is capable of producing, controlling (translation and rotation) and analyzing cold molecular beams at kHz repetition rates and is, therefore, ideally suited for the recording of ultrafast dynamics in so-called "molecular movies".</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><doi>10.48550/arxiv.1301.1826</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2331-8422 |
ispartof | arXiv.org, 2013-05 |
issn | 2331-8422 |
language | eng |
recordid | cdi_proquest_journals_2086082857 |
source | Publicly Available Content Database |
subjects | Alignment Image acquisition Molecular beams Recording Repetition |
title | Strongly aligned and oriented molecular samples at a kHz repetition rate |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T18%3A47%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Strongly%20aligned%20and%20oriented%20molecular%20samples%20at%20a%20kHz%20repetition%20rate&rft.jtitle=arXiv.org&rft.au=Trippel,%20Sebastian&rft.date=2013-05-23&rft.eissn=2331-8422&rft_id=info:doi/10.48550/arxiv.1301.1826&rft_dat=%3Cproquest%3E2086082857%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a517-49e3cf025eec6bffe91cc76003fdea8ff30e17a5a681b8f47fac1841dbfcd8643%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2086082857&rft_id=info:pmid/&rfr_iscdi=true |