Loading…

Experimental study on performance change with time of solar adsorption refrigeration system

•The dynamic performance of the solar adsorption refrigeration system was tested.•The effect of the adsorption time on the system performance was analyzed.•The adsorption capacity changed in a nonlinear way with the adsorption time.•The COP and SCP did not share the same optimal time of the adsorpti...

Full description

Saved in:
Bibliographic Details
Published in:Applied thermal engineering 2018-06, Vol.138, p.386-393
Main Authors: Chen, Q.F., Du, S.W., Yuan, Z.X., Sun, T.B., Li, Y.X.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c395t-453be692481dc83f15e1ab64f04437e4bcf2fbc555b6aa88a6d75a603980267f3
cites cdi_FETCH-LOGICAL-c395t-453be692481dc83f15e1ab64f04437e4bcf2fbc555b6aa88a6d75a603980267f3
container_end_page 393
container_issue
container_start_page 386
container_title Applied thermal engineering
container_volume 138
creator Chen, Q.F.
Du, S.W.
Yuan, Z.X.
Sun, T.B.
Li, Y.X.
description •The dynamic performance of the solar adsorption refrigeration system was tested.•The effect of the adsorption time on the system performance was analyzed.•The adsorption capacity changed in a nonlinear way with the adsorption time.•The COP and SCP did not share the same optimal time of the adsorption. Under the solar heating condition, the performance of the adsorption refrigeration system using SAPO-34 zeolite and water as the working pair was tested practically. The experiment provided insights into the dynamic change of the temperature and pressure in the adsorption bed, as well as the effect of the cycle time on the system performance. By analyzing the relationship between the solar energy input and the cooling output, the optimal cycle time of the system was identified. It was revealed that both the performance coefficient COP and the specific cooling power SCP presented a maximum value with respect to the adsorption time as the system was evaluated by the whole cycle time. However, the COP and the SCP did not share the same adsorption time for their maximum values. The characteristic for the bed to decrease the adsorption rate with the time is considered to be responsible to interpret the optimal cycle time of the system. The overlong time of adsorption did not help to improve the cooling performance of the system.
doi_str_mv 10.1016/j.applthermaleng.2018.04.061
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2112644415</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1359431117359653</els_id><sourcerecordid>2112644415</sourcerecordid><originalsourceid>FETCH-LOGICAL-c395t-453be692481dc83f15e1ab64f04437e4bcf2fbc555b6aa88a6d75a603980267f3</originalsourceid><addsrcrecordid>eNqNkDtPwzAUhSMEEqXwHyzBmmDHj7gSC6paQKrEAhOD5TjXbaI0DrYL9N_jUhY2Jj90zrn3fFl2Q3BBMBG3XaHHsY8b8Fvdw7AuSkxkgVmBBTnJJkRWNOcCi9N0p3yWM0rIeXYRQocxKWXFJtnb4msE325hiLpHIe6aPXIDSn_WpdTBADIbPawBfbZxg2JSImdRcL32SDfB-TG2yeDB-nYNXv-8wj5E2F5mZ1b3Aa5-z2n2uly8zB_z1fPD0_x-lRs64zFnnNYgZiWTpDGSWsKB6FowixmjFbDa2NLWhnNeC62l1KKpuBaYziQuRWXpNLs-5o7eve8gRNW5nR_SSFUSUgrGGOFJdXdUGe9CSPuqMfXWfq8IVgecqlN_caoDToWZSjiTfXm0Q2ry0YJXwbSQ-DStBxNV49r_BX0Do3yIug</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2112644415</pqid></control><display><type>article</type><title>Experimental study on performance change with time of solar adsorption refrigeration system</title><source>ScienceDirect Journals</source><creator>Chen, Q.F. ; Du, S.W. ; Yuan, Z.X. ; Sun, T.B. ; Li, Y.X.</creator><creatorcontrib>Chen, Q.F. ; Du, S.W. ; Yuan, Z.X. ; Sun, T.B. ; Li, Y.X.</creatorcontrib><description>•The dynamic performance of the solar adsorption refrigeration system was tested.•The effect of the adsorption time on the system performance was analyzed.•The adsorption capacity changed in a nonlinear way with the adsorption time.•The COP and SCP did not share the same optimal time of the adsorption. Under the solar heating condition, the performance of the adsorption refrigeration system using SAPO-34 zeolite and water as the working pair was tested practically. The experiment provided insights into the dynamic change of the temperature and pressure in the adsorption bed, as well as the effect of the cycle time on the system performance. By analyzing the relationship between the solar energy input and the cooling output, the optimal cycle time of the system was identified. It was revealed that both the performance coefficient COP and the specific cooling power SCP presented a maximum value with respect to the adsorption time as the system was evaluated by the whole cycle time. However, the COP and the SCP did not share the same adsorption time for their maximum values. The characteristic for the bed to decrease the adsorption rate with the time is considered to be responsible to interpret the optimal cycle time of the system. The overlong time of adsorption did not help to improve the cooling performance of the system.</description><identifier>ISSN: 1359-4311</identifier><identifier>EISSN: 1873-5606</identifier><identifier>DOI: 10.1016/j.applthermaleng.2018.04.061</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Adsorption ; Adsorption refrigeration ; Cycle optimum ; Cycle time ; Heat transfer ; Refrigeration ; Solar energy ; Solar heating ; Zeolites</subject><ispartof>Applied thermal engineering, 2018-06, Vol.138, p.386-393</ispartof><rights>2018 Elsevier Ltd</rights><rights>Copyright Elsevier BV Jun 25, 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c395t-453be692481dc83f15e1ab64f04437e4bcf2fbc555b6aa88a6d75a603980267f3</citedby><cites>FETCH-LOGICAL-c395t-453be692481dc83f15e1ab64f04437e4bcf2fbc555b6aa88a6d75a603980267f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Chen, Q.F.</creatorcontrib><creatorcontrib>Du, S.W.</creatorcontrib><creatorcontrib>Yuan, Z.X.</creatorcontrib><creatorcontrib>Sun, T.B.</creatorcontrib><creatorcontrib>Li, Y.X.</creatorcontrib><title>Experimental study on performance change with time of solar adsorption refrigeration system</title><title>Applied thermal engineering</title><description>•The dynamic performance of the solar adsorption refrigeration system was tested.•The effect of the adsorption time on the system performance was analyzed.•The adsorption capacity changed in a nonlinear way with the adsorption time.•The COP and SCP did not share the same optimal time of the adsorption. Under the solar heating condition, the performance of the adsorption refrigeration system using SAPO-34 zeolite and water as the working pair was tested practically. The experiment provided insights into the dynamic change of the temperature and pressure in the adsorption bed, as well as the effect of the cycle time on the system performance. By analyzing the relationship between the solar energy input and the cooling output, the optimal cycle time of the system was identified. It was revealed that both the performance coefficient COP and the specific cooling power SCP presented a maximum value with respect to the adsorption time as the system was evaluated by the whole cycle time. However, the COP and the SCP did not share the same adsorption time for their maximum values. The characteristic for the bed to decrease the adsorption rate with the time is considered to be responsible to interpret the optimal cycle time of the system. The overlong time of adsorption did not help to improve the cooling performance of the system.</description><subject>Adsorption</subject><subject>Adsorption refrigeration</subject><subject>Cycle optimum</subject><subject>Cycle time</subject><subject>Heat transfer</subject><subject>Refrigeration</subject><subject>Solar energy</subject><subject>Solar heating</subject><subject>Zeolites</subject><issn>1359-4311</issn><issn>1873-5606</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqNkDtPwzAUhSMEEqXwHyzBmmDHj7gSC6paQKrEAhOD5TjXbaI0DrYL9N_jUhY2Jj90zrn3fFl2Q3BBMBG3XaHHsY8b8Fvdw7AuSkxkgVmBBTnJJkRWNOcCi9N0p3yWM0rIeXYRQocxKWXFJtnb4msE325hiLpHIe6aPXIDSn_WpdTBADIbPawBfbZxg2JSImdRcL32SDfB-TG2yeDB-nYNXv-8wj5E2F5mZ1b3Aa5-z2n2uly8zB_z1fPD0_x-lRs64zFnnNYgZiWTpDGSWsKB6FowixmjFbDa2NLWhnNeC62l1KKpuBaYziQuRWXpNLs-5o7eve8gRNW5nR_SSFUSUgrGGOFJdXdUGe9CSPuqMfXWfq8IVgecqlN_caoDToWZSjiTfXm0Q2ry0YJXwbSQ-DStBxNV49r_BX0Do3yIug</recordid><startdate>20180625</startdate><enddate>20180625</enddate><creator>Chen, Q.F.</creator><creator>Du, S.W.</creator><creator>Yuan, Z.X.</creator><creator>Sun, T.B.</creator><creator>Li, Y.X.</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20180625</creationdate><title>Experimental study on performance change with time of solar adsorption refrigeration system</title><author>Chen, Q.F. ; Du, S.W. ; Yuan, Z.X. ; Sun, T.B. ; Li, Y.X.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c395t-453be692481dc83f15e1ab64f04437e4bcf2fbc555b6aa88a6d75a603980267f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Adsorption</topic><topic>Adsorption refrigeration</topic><topic>Cycle optimum</topic><topic>Cycle time</topic><topic>Heat transfer</topic><topic>Refrigeration</topic><topic>Solar energy</topic><topic>Solar heating</topic><topic>Zeolites</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chen, Q.F.</creatorcontrib><creatorcontrib>Du, S.W.</creatorcontrib><creatorcontrib>Yuan, Z.X.</creatorcontrib><creatorcontrib>Sun, T.B.</creatorcontrib><creatorcontrib>Li, Y.X.</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Applied thermal engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chen, Q.F.</au><au>Du, S.W.</au><au>Yuan, Z.X.</au><au>Sun, T.B.</au><au>Li, Y.X.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental study on performance change with time of solar adsorption refrigeration system</atitle><jtitle>Applied thermal engineering</jtitle><date>2018-06-25</date><risdate>2018</risdate><volume>138</volume><spage>386</spage><epage>393</epage><pages>386-393</pages><issn>1359-4311</issn><eissn>1873-5606</eissn><abstract>•The dynamic performance of the solar adsorption refrigeration system was tested.•The effect of the adsorption time on the system performance was analyzed.•The adsorption capacity changed in a nonlinear way with the adsorption time.•The COP and SCP did not share the same optimal time of the adsorption. Under the solar heating condition, the performance of the adsorption refrigeration system using SAPO-34 zeolite and water as the working pair was tested practically. The experiment provided insights into the dynamic change of the temperature and pressure in the adsorption bed, as well as the effect of the cycle time on the system performance. By analyzing the relationship between the solar energy input and the cooling output, the optimal cycle time of the system was identified. It was revealed that both the performance coefficient COP and the specific cooling power SCP presented a maximum value with respect to the adsorption time as the system was evaluated by the whole cycle time. However, the COP and the SCP did not share the same adsorption time for their maximum values. The characteristic for the bed to decrease the adsorption rate with the time is considered to be responsible to interpret the optimal cycle time of the system. The overlong time of adsorption did not help to improve the cooling performance of the system.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.applthermaleng.2018.04.061</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1359-4311
ispartof Applied thermal engineering, 2018-06, Vol.138, p.386-393
issn 1359-4311
1873-5606
language eng
recordid cdi_proquest_journals_2112644415
source ScienceDirect Journals
subjects Adsorption
Adsorption refrigeration
Cycle optimum
Cycle time
Heat transfer
Refrigeration
Solar energy
Solar heating
Zeolites
title Experimental study on performance change with time of solar adsorption refrigeration system
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T01%3A26%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20study%20on%20performance%20change%20with%20time%20of%20solar%20adsorption%20refrigeration%20system&rft.jtitle=Applied%20thermal%20engineering&rft.au=Chen,%20Q.F.&rft.date=2018-06-25&rft.volume=138&rft.spage=386&rft.epage=393&rft.pages=386-393&rft.issn=1359-4311&rft.eissn=1873-5606&rft_id=info:doi/10.1016/j.applthermaleng.2018.04.061&rft_dat=%3Cproquest_cross%3E2112644415%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c395t-453be692481dc83f15e1ab64f04437e4bcf2fbc555b6aa88a6d75a603980267f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2112644415&rft_id=info:pmid/&rfr_iscdi=true