Loading…

Myocardial uptake characteristics of three99mTc-labeled tracers for myocardial perfusion imaging one hour after rest injection

^sup 99m^Tc-tetrofosmin and^sup 99m^Tc-sestamibi are approved tracers for myocardial perfusion studies. Recently, a^sup 99m^Tc-MIBI preparation from a different manufacturer (^sup 99m^Tc-cardiospect-MIBI) has been introduced to the market. Therefore, the aim of this study was the evaluation of^sup 9...

Full description

Saved in:
Bibliographic Details
Published in:Annals of nuclear medicine 2006-12, Vol.20 (10), p.663-670
Main Authors: Manka-Waluch, Agnieszka, Palmedo, Holger, Reinhardt, Michael J., Joe, Alexius Y., Guhlke, Stefan, Biersack, Hans-Jürgen, Bucerius, Jan, Manka, christoph
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:^sup 99m^Tc-tetrofosmin and^sup 99m^Tc-sestamibi are approved tracers for myocardial perfusion studies. Recently, a^sup 99m^Tc-MIBI preparation from a different manufacturer (^sup 99m^Tc-cardiospect-MIBI) has been introduced to the market. Therefore, the aim of this study was the evaluation of^sup 99m^Tc-tetrofosmin as well as of two different^sup 99m^Tc-labeled MIBI tracers with regard to differences in imaging quality under resting conditions. Sixty patients (mean age 63.8 years ± 1.25) with known or suspected coronary artery disease but without evidence of rest-ischemia were included. Twenty patients in each group were examined by a two-day-rest-stress protocol using the three^sup 99m^Tc-labeled tracers. Visual analysis of all images was performed by two experienced physicians blinded with regard to the applied tracer. Regions of interest (ROI) were defined over the heart, lung and whole body only in the rest imaging in order to calculate heart-to-lung, lung-to-whole body-, and heart-to-whole body-ratios. The heart-to-lung ratio was statistically significant higher for^sup 99m^Tc-cardiospect-MIBI as compared to^sup 99m^Tc-sestamibi as well as to^sup 99m^Tc-tetrofosmin. Furthermore, a significantly higher heart-to-lung ratio was found for^sup 99m^Tc-sestamibi as compared to^sup 99m^Tc-tetrofosmin. The heart-to-whole body-ratio and the lung-to-whole body-ratio were equivalent between all tracers. Visual analysis revealed only slight differences regarding image quality between all tracers. ROI analysis surprisingly revealed a significant higher myocardial uptake and consequently a higher heart-to-lung ratio for^sup 99m^Tc-cardiospect-MIBI. Whether this leads to a better visual image quality has to be evaluated in future studies with larger study populations as well as semiquantitative segmental analysis of the myocardial perfusion images.[PUBLICATION ABSTRACT]
ISSN:0914-7187
1864-6433
DOI:10.1007/BF02984677