Loading…

Technical Note: A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate In Vivo Dosimetry in HDR Brachytherapy

Since large dose are administrated to the patient in brachytherapy treatment, ensuring the right dose is delivered is highly critical. This study presents a first step in solving the standing issue of accurately knowing the dosimeter position at all time during in vivo dosimetry. In this work, an en...

Full description

Saved in:
Bibliographic Details
Published in:arXiv.org 2018-12
Main Authors: Daline Tho, Beaulieu, Luc
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Daline Tho
Beaulieu, Luc
description Since large dose are administrated to the patient in brachytherapy treatment, ensuring the right dose is delivered is highly critical. This study presents a first step in solving the standing issue of accurately knowing the dosimeter position at all time during in vivo dosimetry. In this work, an energy independent dosimeter, namely plastic scintillation detector, is coupled to an electromagnetic (EM) sensor having sub-mm positional accuracy for real-time tracking of the dosimeter position. However, adding an EM sensor adds materials in the path to the scintillator and thus could potentially perturb the dose measurements.To confirm the perturbation presence, 4 different sensors were placed in front of the scintillator so the radiation does not arrive to it directly. Variation of the distance between the sensor and the scintillator was used to quantify the effect on the signal at 0{\deg} and 90{\deg}.To test the dependence for each sensor, the signal measurement were taken from 0{\deg} to 90{\deg} with 10\({\deg}\) increment. The 5PCBDOF sensor showed an increased signal of almost \(20{\%}\) with increasing beam angle. Sensor 5DOF, 5DOFthin and 6DOFshowed no significant angle dependance.The 6DOF and 5DOFthin sensor's cable revealed no extra signal attenuation. The latter gives a smaller overall attenuation. Therefore, the 5DOFthin is chosen to be part of the novel dosimeter construction. It has a jitter error of \(\pm\) 0.06 mm and a reproductibility of\( {\pm}\) 0.008 mm. In the optimal operating range, the average positional uncertainty is less than 0.2 mm. Average angle errors are at most of 1.1\({\deg}\). It is feasible to integrate an EM tracking sensor to an energy independent plastic scintillation dosimeter with minimal impact to the collected signal as well as sufficient positional accuracy to keep dose uncertainty below 5\({\%}\).
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2160979296</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2160979296</sourcerecordid><originalsourceid>FETCH-proquest_journals_21609792963</originalsourceid><addsrcrecordid>eNqNjLFqwzAUAEWhkNDmHx50NthybcfdnMQhXTokpmsQynOsVJbSp-eAyc_XQ7t3uuGOexBzmaZJtHyVciYWIVziOJZ5IbMsnYt7g7pzRisLH57xDaqJN7RQW9RMvldnh2x01JDSX3iCgzaOjbWKjXew8cH0yEjQeoJK64EUI7w7-DQ3_6dpBONgt9nDarp0I3dI6jo-i8dW2YCLXz6Jl23drHfRlfz3gIGPFz-Qm9RRJnlcFqUs8_R_1Q8QNE5l</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2160979296</pqid></control><display><type>article</type><title>Technical Note: A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate In Vivo Dosimetry in HDR Brachytherapy</title><source>Publicly Available Content Database</source><creator>Daline Tho ; Beaulieu, Luc</creator><creatorcontrib>Daline Tho ; Beaulieu, Luc</creatorcontrib><description>Since large dose are administrated to the patient in brachytherapy treatment, ensuring the right dose is delivered is highly critical. This study presents a first step in solving the standing issue of accurately knowing the dosimeter position at all time during in vivo dosimetry. In this work, an energy independent dosimeter, namely plastic scintillation detector, is coupled to an electromagnetic (EM) sensor having sub-mm positional accuracy for real-time tracking of the dosimeter position. However, adding an EM sensor adds materials in the path to the scintillator and thus could potentially perturb the dose measurements.To confirm the perturbation presence, 4 different sensors were placed in front of the scintillator so the radiation does not arrive to it directly. Variation of the distance between the sensor and the scintillator was used to quantify the effect on the signal at 0{\deg} and 90{\deg}.To test the dependence for each sensor, the signal measurement were taken from 0{\deg} to 90{\deg} with 10\({\deg}\) increment. The 5PCBDOF sensor showed an increased signal of almost \(20{\%}\) with increasing beam angle. Sensor 5DOF, 5DOFthin and 6DOFshowed no significant angle dependance.The 6DOF and 5DOFthin sensor's cable revealed no extra signal attenuation. The latter gives a smaller overall attenuation. Therefore, the 5DOFthin is chosen to be part of the novel dosimeter construction. It has a jitter error of \(\pm\) 0.06 mm and a reproductibility of\( {\pm}\) 0.008 mm. In the optimal operating range, the average positional uncertainty is less than 0.2 mm. Average angle errors are at most of 1.1\({\deg}\). It is feasible to integrate an EM tracking sensor to an energy independent plastic scintillation dosimeter with minimal impact to the collected signal as well as sufficient positional accuracy to keep dose uncertainty below 5\({\%}\).</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Attenuation ; Dependence ; Dosimeters ; Dosimetry ; In vivo methods and tests ; Perturbation ; Position sensing ; Radiation therapy ; Scintillation ; Scintillation counters ; Sensors ; Signal measurement ; Tracking ; Uncertainty ; Vibration</subject><ispartof>arXiv.org, 2018-12</ispartof><rights>2018. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2160979296?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>780,784,25753,37012,44590</link.rule.ids></links><search><creatorcontrib>Daline Tho</creatorcontrib><creatorcontrib>Beaulieu, Luc</creatorcontrib><title>Technical Note: A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate In Vivo Dosimetry in HDR Brachytherapy</title><title>arXiv.org</title><description>Since large dose are administrated to the patient in brachytherapy treatment, ensuring the right dose is delivered is highly critical. This study presents a first step in solving the standing issue of accurately knowing the dosimeter position at all time during in vivo dosimetry. In this work, an energy independent dosimeter, namely plastic scintillation detector, is coupled to an electromagnetic (EM) sensor having sub-mm positional accuracy for real-time tracking of the dosimeter position. However, adding an EM sensor adds materials in the path to the scintillator and thus could potentially perturb the dose measurements.To confirm the perturbation presence, 4 different sensors were placed in front of the scintillator so the radiation does not arrive to it directly. Variation of the distance between the sensor and the scintillator was used to quantify the effect on the signal at 0{\deg} and 90{\deg}.To test the dependence for each sensor, the signal measurement were taken from 0{\deg} to 90{\deg} with 10\({\deg}\) increment. The 5PCBDOF sensor showed an increased signal of almost \(20{\%}\) with increasing beam angle. Sensor 5DOF, 5DOFthin and 6DOFshowed no significant angle dependance.The 6DOF and 5DOFthin sensor's cable revealed no extra signal attenuation. The latter gives a smaller overall attenuation. Therefore, the 5DOFthin is chosen to be part of the novel dosimeter construction. It has a jitter error of \(\pm\) 0.06 mm and a reproductibility of\( {\pm}\) 0.008 mm. In the optimal operating range, the average positional uncertainty is less than 0.2 mm. Average angle errors are at most of 1.1\({\deg}\). It is feasible to integrate an EM tracking sensor to an energy independent plastic scintillation dosimeter with minimal impact to the collected signal as well as sufficient positional accuracy to keep dose uncertainty below 5\({\%}\).</description><subject>Attenuation</subject><subject>Dependence</subject><subject>Dosimeters</subject><subject>Dosimetry</subject><subject>In vivo methods and tests</subject><subject>Perturbation</subject><subject>Position sensing</subject><subject>Radiation therapy</subject><subject>Scintillation</subject><subject>Scintillation counters</subject><subject>Sensors</subject><subject>Signal measurement</subject><subject>Tracking</subject><subject>Uncertainty</subject><subject>Vibration</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqNjLFqwzAUAEWhkNDmHx50NthybcfdnMQhXTokpmsQynOsVJbSp-eAyc_XQ7t3uuGOexBzmaZJtHyVciYWIVziOJZ5IbMsnYt7g7pzRisLH57xDaqJN7RQW9RMvldnh2x01JDSX3iCgzaOjbWKjXew8cH0yEjQeoJK64EUI7w7-DQ3_6dpBONgt9nDarp0I3dI6jo-i8dW2YCLXz6Jl23drHfRlfz3gIGPFz-Qm9RRJnlcFqUs8_R_1Q8QNE5l</recordid><startdate>20181222</startdate><enddate>20181222</enddate><creator>Daline Tho</creator><creator>Beaulieu, Luc</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20181222</creationdate><title>Technical Note: A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate In Vivo Dosimetry in HDR Brachytherapy</title><author>Daline Tho ; Beaulieu, Luc</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_21609792963</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Attenuation</topic><topic>Dependence</topic><topic>Dosimeters</topic><topic>Dosimetry</topic><topic>In vivo methods and tests</topic><topic>Perturbation</topic><topic>Position sensing</topic><topic>Radiation therapy</topic><topic>Scintillation</topic><topic>Scintillation counters</topic><topic>Sensors</topic><topic>Signal measurement</topic><topic>Tracking</topic><topic>Uncertainty</topic><topic>Vibration</topic><toplevel>online_resources</toplevel><creatorcontrib>Daline Tho</creatorcontrib><creatorcontrib>Beaulieu, Luc</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Daline Tho</au><au>Beaulieu, Luc</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>Technical Note: A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate In Vivo Dosimetry in HDR Brachytherapy</atitle><jtitle>arXiv.org</jtitle><date>2018-12-22</date><risdate>2018</risdate><eissn>2331-8422</eissn><abstract>Since large dose are administrated to the patient in brachytherapy treatment, ensuring the right dose is delivered is highly critical. This study presents a first step in solving the standing issue of accurately knowing the dosimeter position at all time during in vivo dosimetry. In this work, an energy independent dosimeter, namely plastic scintillation detector, is coupled to an electromagnetic (EM) sensor having sub-mm positional accuracy for real-time tracking of the dosimeter position. However, adding an EM sensor adds materials in the path to the scintillator and thus could potentially perturb the dose measurements.To confirm the perturbation presence, 4 different sensors were placed in front of the scintillator so the radiation does not arrive to it directly. Variation of the distance between the sensor and the scintillator was used to quantify the effect on the signal at 0{\deg} and 90{\deg}.To test the dependence for each sensor, the signal measurement were taken from 0{\deg} to 90{\deg} with 10\({\deg}\) increment. The 5PCBDOF sensor showed an increased signal of almost \(20{\%}\) with increasing beam angle. Sensor 5DOF, 5DOFthin and 6DOFshowed no significant angle dependance.The 6DOF and 5DOFthin sensor's cable revealed no extra signal attenuation. The latter gives a smaller overall attenuation. Therefore, the 5DOFthin is chosen to be part of the novel dosimeter construction. It has a jitter error of \(\pm\) 0.06 mm and a reproductibility of\( {\pm}\) 0.008 mm. In the optimal operating range, the average positional uncertainty is less than 0.2 mm. Average angle errors are at most of 1.1\({\deg}\). It is feasible to integrate an EM tracking sensor to an energy independent plastic scintillation dosimeter with minimal impact to the collected signal as well as sufficient positional accuracy to keep dose uncertainty below 5\({\%}\).</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2018-12
issn 2331-8422
language eng
recordid cdi_proquest_journals_2160979296
source Publicly Available Content Database
subjects Attenuation
Dependence
Dosimeters
Dosimetry
In vivo methods and tests
Perturbation
Position sensing
Radiation therapy
Scintillation
Scintillation counters
Sensors
Signal measurement
Tracking
Uncertainty
Vibration
title Technical Note: A Novel Electromagnetic-Tracked Scintillation Dosimeter for Accurate In Vivo Dosimetry in HDR Brachytherapy
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T10%3A55%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=Technical%20Note:%20A%20Novel%20Electromagnetic-Tracked%20Scintillation%20Dosimeter%20for%20Accurate%20In%20Vivo%20Dosimetry%20in%20HDR%20Brachytherapy&rft.jtitle=arXiv.org&rft.au=Daline%20Tho&rft.date=2018-12-22&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E2160979296%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_journals_21609792963%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2160979296&rft_id=info:pmid/&rfr_iscdi=true