Loading…
35 years of photovoltaics: Analysis of the TISO‐10‐kW solar plant, lessons learnt in safety and performance—Part 1
The TISO‐10‐kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. Its history is well documented, and the full set of modules has been tested indoors at regular intervals over the years. After 35 years of operation, we observe an increase in the degradatio...
Saved in:
Published in: | Progress in photovoltaics 2019-04, Vol.27 (4), p.328-339 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3514-54774d9af18e45dfb835d71897d5ac57ee4fd051589318d069bcfd8771b7c1473 |
---|---|
cites | cdi_FETCH-LOGICAL-c3514-54774d9af18e45dfb835d71897d5ac57ee4fd051589318d069bcfd8771b7c1473 |
container_end_page | 339 |
container_issue | 4 |
container_start_page | 328 |
container_title | Progress in photovoltaics |
container_volume | 27 |
creator | Virtuani, Alessandro Caccivio, Mauro Annigoni, Eleonora Friesen, Gabi Chianese, Domenico Ballif, Christophe Sample, Tony |
description | The TISO‐10‐kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. Its history is well documented, and the full set of modules has been tested indoors at regular intervals over the years. After 35 years of operation, we observe an increase in the degradation rates and that the distributions of modules' performances are drastically changing compared with previous years. Two groups of modules can be observed: (a) group 1: 21.5% of the modules show a very modest degradation, described by a Gaussian distribution with mean yearly power degradation of only −0.2%/y. (b) Group 2: 72.9% of the modules form a negatively skewed distribution with a long tail described by mode (−0.54%/y), median (−0.62%/y), and mean (−0.69%/y) values. In earlier years, decreases in performances could strongly be correlated to losses in fill factor (FF). After 35 years, the situation changes and, for a subset of modules, losses in the current (Isc) are superimposed to losses in FF. The reasons for this will become clearer in part 2, where we will present results of a detailed visual inspection on the whole set of modules and will focus on safety aspect too. We conclude that, after 35 years of operation in a temperate climate, approximately 60% (~70% if considering a ± 3% measurement uncertainty) of the modules would still satisfy a warranty criteria that module manufacturers are presently considering to apply to the technology of tomorrow: 35 years of operation with a performance threshold set at 80% of the initial value.
The TISO‐10‐kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. After 35 years of operation in a temperate climate, approximately 60% (~70% if considering a ± 3% measurement uncertainty) of the modules would still satisfy a warranty criteria that module manufacturers are presently considering to apply to the technology of tomorrow: 35 years of operation with a performance threshold set at 80% of the initial value. |
doi_str_mv | 10.1002/pip.3104 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2194403782</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2194403782</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3514-54774d9af18e45dfb835d71897d5ac57ee4fd051589318d069bcfd8771b7c1473</originalsourceid><addsrcrecordid>eNp1kE9KAzEUh4MoWKvgEQJuXDg1r5M0ibtS_FMotGBFd0M6k9Cp08mYpMrsegQXHsCzeJSexGnr1s37Pfh9PHgfQudAOkBI97rKq04MhB6gFhApI2Dy5XC797oRl5IdoxPvF4QAF7LXQnXMfr5rrZzH1uBqboN9t0VQeepvcL9URe3zXRXmGk-Hj-PN-hNIM16fsbeFcrgqVBmucKG9t6VvUrky4LzEXhkdaqzKDFfaGeuWqkz1Zv01US5gOEVHRhVen_1lGz3d3U4HD9FofD8c9EdRGjOgEaOc00wqA0JTlpmZiFnGQUieMZUyrjU1GWHAhIxBZKQnZ6nJBOcw4ylQHrfRxf5u5ezbSvuQLOzKNZ_5pAuSUhJz0W2oyz2VOuu90yapXL5Urk6AJFuxSSM22Ypt0GiPfuSFrv_lkslwsuN_Abe_fKE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2194403782</pqid></control><display><type>article</type><title>35 years of photovoltaics: Analysis of the TISO‐10‐kW solar plant, lessons learnt in safety and performance—Part 1</title><source>Wiley-Blackwell Read & Publish Collection</source><creator>Virtuani, Alessandro ; Caccivio, Mauro ; Annigoni, Eleonora ; Friesen, Gabi ; Chianese, Domenico ; Ballif, Christophe ; Sample, Tony</creator><creatorcontrib>Virtuani, Alessandro ; Caccivio, Mauro ; Annigoni, Eleonora ; Friesen, Gabi ; Chianese, Domenico ; Ballif, Christophe ; Sample, Tony</creatorcontrib><description>The TISO‐10‐kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. Its history is well documented, and the full set of modules has been tested indoors at regular intervals over the years. After 35 years of operation, we observe an increase in the degradation rates and that the distributions of modules' performances are drastically changing compared with previous years. Two groups of modules can be observed: (a) group 1: 21.5% of the modules show a very modest degradation, described by a Gaussian distribution with mean yearly power degradation of only −0.2%/y. (b) Group 2: 72.9% of the modules form a negatively skewed distribution with a long tail described by mode (−0.54%/y), median (−0.62%/y), and mean (−0.69%/y) values. In earlier years, decreases in performances could strongly be correlated to losses in fill factor (FF). After 35 years, the situation changes and, for a subset of modules, losses in the current (Isc) are superimposed to losses in FF. The reasons for this will become clearer in part 2, where we will present results of a detailed visual inspection on the whole set of modules and will focus on safety aspect too. We conclude that, after 35 years of operation in a temperate climate, approximately 60% (~70% if considering a ± 3% measurement uncertainty) of the modules would still satisfy a warranty criteria that module manufacturers are presently considering to apply to the technology of tomorrow: 35 years of operation with a performance threshold set at 80% of the initial value.
The TISO‐10‐kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. After 35 years of operation in a temperate climate, approximately 60% (~70% if considering a ± 3% measurement uncertainty) of the modules would still satisfy a warranty criteria that module manufacturers are presently considering to apply to the technology of tomorrow: 35 years of operation with a performance threshold set at 80% of the initial value.</description><identifier>ISSN: 1062-7995</identifier><identifier>EISSN: 1099-159X</identifier><identifier>DOI: 10.1002/pip.3104</identifier><language>eng</language><publisher>Bognor Regis: Wiley Subscription Services, Inc</publisher><subject>crystalline silicon ; Degradation ; durability ; Electric power distribution ; Gaussian distribution ; long‐term performance ; Modules ; Normal distribution ; Photovoltaic cells ; reliability ; Safety ; Skewed distributions ; Solar cells ; solar modules ; wear‐out mechanisms</subject><ispartof>Progress in photovoltaics, 2019-04, Vol.27 (4), p.328-339</ispartof><rights>2019 John Wiley & Sons, Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3514-54774d9af18e45dfb835d71897d5ac57ee4fd051589318d069bcfd8771b7c1473</citedby><cites>FETCH-LOGICAL-c3514-54774d9af18e45dfb835d71897d5ac57ee4fd051589318d069bcfd8771b7c1473</cites><orcidid>0000-0003-0255-3031 ; 0000-0001-5523-5200</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail></links><search><creatorcontrib>Virtuani, Alessandro</creatorcontrib><creatorcontrib>Caccivio, Mauro</creatorcontrib><creatorcontrib>Annigoni, Eleonora</creatorcontrib><creatorcontrib>Friesen, Gabi</creatorcontrib><creatorcontrib>Chianese, Domenico</creatorcontrib><creatorcontrib>Ballif, Christophe</creatorcontrib><creatorcontrib>Sample, Tony</creatorcontrib><title>35 years of photovoltaics: Analysis of the TISO‐10‐kW solar plant, lessons learnt in safety and performance—Part 1</title><title>Progress in photovoltaics</title><description>The TISO‐10‐kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. Its history is well documented, and the full set of modules has been tested indoors at regular intervals over the years. After 35 years of operation, we observe an increase in the degradation rates and that the distributions of modules' performances are drastically changing compared with previous years. Two groups of modules can be observed: (a) group 1: 21.5% of the modules show a very modest degradation, described by a Gaussian distribution with mean yearly power degradation of only −0.2%/y. (b) Group 2: 72.9% of the modules form a negatively skewed distribution with a long tail described by mode (−0.54%/y), median (−0.62%/y), and mean (−0.69%/y) values. In earlier years, decreases in performances could strongly be correlated to losses in fill factor (FF). After 35 years, the situation changes and, for a subset of modules, losses in the current (Isc) are superimposed to losses in FF. The reasons for this will become clearer in part 2, where we will present results of a detailed visual inspection on the whole set of modules and will focus on safety aspect too. We conclude that, after 35 years of operation in a temperate climate, approximately 60% (~70% if considering a ± 3% measurement uncertainty) of the modules would still satisfy a warranty criteria that module manufacturers are presently considering to apply to the technology of tomorrow: 35 years of operation with a performance threshold set at 80% of the initial value.
The TISO‐10‐kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. After 35 years of operation in a temperate climate, approximately 60% (~70% if considering a ± 3% measurement uncertainty) of the modules would still satisfy a warranty criteria that module manufacturers are presently considering to apply to the technology of tomorrow: 35 years of operation with a performance threshold set at 80% of the initial value.</description><subject>crystalline silicon</subject><subject>Degradation</subject><subject>durability</subject><subject>Electric power distribution</subject><subject>Gaussian distribution</subject><subject>long‐term performance</subject><subject>Modules</subject><subject>Normal distribution</subject><subject>Photovoltaic cells</subject><subject>reliability</subject><subject>Safety</subject><subject>Skewed distributions</subject><subject>Solar cells</subject><subject>solar modules</subject><subject>wear‐out mechanisms</subject><issn>1062-7995</issn><issn>1099-159X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp1kE9KAzEUh4MoWKvgEQJuXDg1r5M0ibtS_FMotGBFd0M6k9Cp08mYpMrsegQXHsCzeJSexGnr1s37Pfh9PHgfQudAOkBI97rKq04MhB6gFhApI2Dy5XC797oRl5IdoxPvF4QAF7LXQnXMfr5rrZzH1uBqboN9t0VQeepvcL9URe3zXRXmGk-Hj-PN-hNIM16fsbeFcrgqVBmucKG9t6VvUrky4LzEXhkdaqzKDFfaGeuWqkz1Zv01US5gOEVHRhVen_1lGz3d3U4HD9FofD8c9EdRGjOgEaOc00wqA0JTlpmZiFnGQUieMZUyrjU1GWHAhIxBZKQnZ6nJBOcw4ylQHrfRxf5u5ezbSvuQLOzKNZ_5pAuSUhJz0W2oyz2VOuu90yapXL5Urk6AJFuxSSM22Ypt0GiPfuSFrv_lkslwsuN_Abe_fKE</recordid><startdate>201904</startdate><enddate>201904</enddate><creator>Virtuani, Alessandro</creator><creator>Caccivio, Mauro</creator><creator>Annigoni, Eleonora</creator><creator>Friesen, Gabi</creator><creator>Chianese, Domenico</creator><creator>Ballif, Christophe</creator><creator>Sample, Tony</creator><general>Wiley Subscription Services, Inc</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope><orcidid>https://orcid.org/0000-0003-0255-3031</orcidid><orcidid>https://orcid.org/0000-0001-5523-5200</orcidid></search><sort><creationdate>201904</creationdate><title>35 years of photovoltaics: Analysis of the TISO‐10‐kW solar plant, lessons learnt in safety and performance—Part 1</title><author>Virtuani, Alessandro ; Caccivio, Mauro ; Annigoni, Eleonora ; Friesen, Gabi ; Chianese, Domenico ; Ballif, Christophe ; Sample, Tony</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3514-54774d9af18e45dfb835d71897d5ac57ee4fd051589318d069bcfd8771b7c1473</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>crystalline silicon</topic><topic>Degradation</topic><topic>durability</topic><topic>Electric power distribution</topic><topic>Gaussian distribution</topic><topic>long‐term performance</topic><topic>Modules</topic><topic>Normal distribution</topic><topic>Photovoltaic cells</topic><topic>reliability</topic><topic>Safety</topic><topic>Skewed distributions</topic><topic>Solar cells</topic><topic>solar modules</topic><topic>wear‐out mechanisms</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Virtuani, Alessandro</creatorcontrib><creatorcontrib>Caccivio, Mauro</creatorcontrib><creatorcontrib>Annigoni, Eleonora</creatorcontrib><creatorcontrib>Friesen, Gabi</creatorcontrib><creatorcontrib>Chianese, Domenico</creatorcontrib><creatorcontrib>Ballif, Christophe</creatorcontrib><creatorcontrib>Sample, Tony</creatorcontrib><collection>CrossRef</collection><collection>Electronics & Communications Abstracts</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Progress in photovoltaics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Virtuani, Alessandro</au><au>Caccivio, Mauro</au><au>Annigoni, Eleonora</au><au>Friesen, Gabi</au><au>Chianese, Domenico</au><au>Ballif, Christophe</au><au>Sample, Tony</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>35 years of photovoltaics: Analysis of the TISO‐10‐kW solar plant, lessons learnt in safety and performance—Part 1</atitle><jtitle>Progress in photovoltaics</jtitle><date>2019-04</date><risdate>2019</risdate><volume>27</volume><issue>4</issue><spage>328</spage><epage>339</epage><pages>328-339</pages><issn>1062-7995</issn><eissn>1099-159X</eissn><abstract>The TISO‐10‐kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. Its history is well documented, and the full set of modules has been tested indoors at regular intervals over the years. After 35 years of operation, we observe an increase in the degradation rates and that the distributions of modules' performances are drastically changing compared with previous years. Two groups of modules can be observed: (a) group 1: 21.5% of the modules show a very modest degradation, described by a Gaussian distribution with mean yearly power degradation of only −0.2%/y. (b) Group 2: 72.9% of the modules form a negatively skewed distribution with a long tail described by mode (−0.54%/y), median (−0.62%/y), and mean (−0.69%/y) values. In earlier years, decreases in performances could strongly be correlated to losses in fill factor (FF). After 35 years, the situation changes and, for a subset of modules, losses in the current (Isc) are superimposed to losses in FF. The reasons for this will become clearer in part 2, where we will present results of a detailed visual inspection on the whole set of modules and will focus on safety aspect too. We conclude that, after 35 years of operation in a temperate climate, approximately 60% (~70% if considering a ± 3% measurement uncertainty) of the modules would still satisfy a warranty criteria that module manufacturers are presently considering to apply to the technology of tomorrow: 35 years of operation with a performance threshold set at 80% of the initial value.
The TISO‐10‐kW solar plant, connected to the grid in 1982, is the oldest installation of this kind in Europe. After 35 years of operation in a temperate climate, approximately 60% (~70% if considering a ± 3% measurement uncertainty) of the modules would still satisfy a warranty criteria that module manufacturers are presently considering to apply to the technology of tomorrow: 35 years of operation with a performance threshold set at 80% of the initial value.</abstract><cop>Bognor Regis</cop><pub>Wiley Subscription Services, Inc</pub><doi>10.1002/pip.3104</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0003-0255-3031</orcidid><orcidid>https://orcid.org/0000-0001-5523-5200</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1062-7995 |
ispartof | Progress in photovoltaics, 2019-04, Vol.27 (4), p.328-339 |
issn | 1062-7995 1099-159X |
language | eng |
recordid | cdi_proquest_journals_2194403782 |
source | Wiley-Blackwell Read & Publish Collection |
subjects | crystalline silicon Degradation durability Electric power distribution Gaussian distribution long‐term performance Modules Normal distribution Photovoltaic cells reliability Safety Skewed distributions Solar cells solar modules wear‐out mechanisms |
title | 35 years of photovoltaics: Analysis of the TISO‐10‐kW solar plant, lessons learnt in safety and performance—Part 1 |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-03-09T22%3A03%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=35%C2%A0years%20of%20photovoltaics:%20Analysis%20of%20the%20TISO%E2%80%9010%E2%80%90kW%20solar%20plant,%20lessons%20learnt%20in%20safety%20and%20performance%E2%80%94Part%201&rft.jtitle=Progress%20in%20photovoltaics&rft.au=Virtuani,%20Alessandro&rft.date=2019-04&rft.volume=27&rft.issue=4&rft.spage=328&rft.epage=339&rft.pages=328-339&rft.issn=1062-7995&rft.eissn=1099-159X&rft_id=info:doi/10.1002/pip.3104&rft_dat=%3Cproquest_cross%3E2194403782%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3514-54774d9af18e45dfb835d71897d5ac57ee4fd051589318d069bcfd8771b7c1473%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2194403782&rft_id=info:pmid/&rfr_iscdi=true |