Loading…
Effect of Beam-Column Connection Fixity on Collapse Performance of a Six-Storey Special Concentrically Braced Frame
Concentrically braced frames are one of the most common seismic force resisting systems because of their high strength and stiffness. In current practice, the gusset plates that connect the brace to the adjacent beams and columns can increase the strength and stiffness of the connection significantl...
Saved in:
Published in: | Key engineering materials 2018-02, Vol.763, p.157-164 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c2107-ace770ba32d94c3c0045dff6ff3a3d0c61d7f9cb43f8b73153dd56d95eb362133 |
container_end_page | 164 |
container_issue | |
container_start_page | 157 |
container_title | Key engineering materials |
container_volume | 763 |
creator | Wiebe, Lydell D.A. Mohsenzadeh, Vahid |
description | Concentrically braced frames are one of the most common seismic force resisting systems because of their high strength and stiffness. In current practice, the gusset plates that connect the brace to the adjacent beams and columns can increase the strength and stiffness of the connection significantly. This strength and stiffness can provide a reserve of lateral force resisting capacity during a large earthquake, which may play a role in the seismic collapse behaviour of the braced frame. An alternative connection has recently been proposed as a means of ensuring that brace buckling occurs only in-plane, that no field welding is required, and that all damage is confined to a replaceable brace module. However, the proposed connection does not include a gusset plate that can provide a similar stiffness and reserve capacity. In order to investigate the potential influence of the range of possible beam-column-gusset plate designs, this paper assesses the effect of the fixity of these connections on the behavior of a six-storey special concentrically braced frame. Nonlinear dynamic analyses have been conducted to determine the seismic performance of the frame with this connection modelled using three different assumptions (pinned, shear tab and fixed), and the collapse risk is assessed using the FEMA P695 methodology. The results show that when the gravity framing is not modelled, the fixity of the beam-column connections is important in avoiding the formation of a soft storey under extreme earthquakes, thereby reducing the probability of collapse of the building. |
doi_str_mv | 10.4028/www.scientific.net/KEM.763.157 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2199070697</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2199070697</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2107-ace770ba32d94c3c0045dff6ff3a3d0c61d7f9cb43f8b73153dd56d95eb362133</originalsourceid><addsrcrecordid>eNqNkMFKAzEQhhdRsFbfISB4222y6SbNRbRLq2JFoXoOaTbBlN1kTVLavr0pFXr1NMPwzzfDl2V3CBZjWE5G2-22CNIoG402srAqjl5nbwUluEAVPcsGiJAyZ5RV56mHCOdsUpLL7CqENYQYTVA1yMJMayUjcBpMlejy2rWbzoLaWZvGxlkwNzsT98Adhm0r-qDAh_La-U5YqQ6LAizNLl9G59UeLHsljWgPBJle80aKtt2DqRdSNWDuRaeuswst2qBu_uow-5rPPuvnfPH-9FI_LnJZIkjztEApXAlcNmwssYRwXDVaE62xwA2UBDVUM7kaYz1ZUYwq3DQVaVilVpiUCONhdnvk9t79bFSIfO023qaTvESMQQoJoyl1f0xJ70LwSvPem074PUeQH0TzJJqfRPMkmifRPInmSXQCPBwB0QsbopLfpzv_RPwCJtOQlQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2199070697</pqid></control><display><type>article</type><title>Effect of Beam-Column Connection Fixity on Collapse Performance of a Six-Storey Special Concentrically Braced Frame</title><source>Scientific.net Journals</source><creator>Wiebe, Lydell D.A. ; Mohsenzadeh, Vahid</creator><creatorcontrib>Wiebe, Lydell D.A. ; Mohsenzadeh, Vahid</creatorcontrib><description>Concentrically braced frames are one of the most common seismic force resisting systems because of their high strength and stiffness. In current practice, the gusset plates that connect the brace to the adjacent beams and columns can increase the strength and stiffness of the connection significantly. This strength and stiffness can provide a reserve of lateral force resisting capacity during a large earthquake, which may play a role in the seismic collapse behaviour of the braced frame. An alternative connection has recently been proposed as a means of ensuring that brace buckling occurs only in-plane, that no field welding is required, and that all damage is confined to a replaceable brace module. However, the proposed connection does not include a gusset plate that can provide a similar stiffness and reserve capacity. In order to investigate the potential influence of the range of possible beam-column-gusset plate designs, this paper assesses the effect of the fixity of these connections on the behavior of a six-storey special concentrically braced frame. Nonlinear dynamic analyses have been conducted to determine the seismic performance of the frame with this connection modelled using three different assumptions (pinned, shear tab and fixed), and the collapse risk is assessed using the FEMA P695 methodology. The results show that when the gravity framing is not modelled, the fixity of the beam-column connections is important in avoiding the formation of a soft storey under extreme earthquakes, thereby reducing the probability of collapse of the building.</description><identifier>ISSN: 1013-9826</identifier><identifier>ISSN: 1662-9795</identifier><identifier>EISSN: 1662-9795</identifier><identifier>DOI: 10.4028/www.scientific.net/KEM.763.157</identifier><language>eng</language><publisher>Zurich: Trans Tech Publications Ltd</publisher><subject>Beam-columns ; Collapse ; Dynamical systems ; Earthquake damage ; Earthquakes ; Gusset plates ; Nonlinear analysis ; Nonlinear dynamics ; Reinforcement (structures) ; Reserve capacity ; Seismic design ; Seismic engineering ; Seismic response ; Stiffness</subject><ispartof>Key engineering materials, 2018-02, Vol.763, p.157-164</ispartof><rights>2018 Trans Tech Publications Ltd</rights><rights>Copyright Trans Tech Publications Ltd. Feb 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2107-ace770ba32d94c3c0045dff6ff3a3d0c61d7f9cb43f8b73153dd56d95eb362133</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.scientific.net/Image/TitleCover/4651?width=600</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Wiebe, Lydell D.A.</creatorcontrib><creatorcontrib>Mohsenzadeh, Vahid</creatorcontrib><title>Effect of Beam-Column Connection Fixity on Collapse Performance of a Six-Storey Special Concentrically Braced Frame</title><title>Key engineering materials</title><description>Concentrically braced frames are one of the most common seismic force resisting systems because of their high strength and stiffness. In current practice, the gusset plates that connect the brace to the adjacent beams and columns can increase the strength and stiffness of the connection significantly. This strength and stiffness can provide a reserve of lateral force resisting capacity during a large earthquake, which may play a role in the seismic collapse behaviour of the braced frame. An alternative connection has recently been proposed as a means of ensuring that brace buckling occurs only in-plane, that no field welding is required, and that all damage is confined to a replaceable brace module. However, the proposed connection does not include a gusset plate that can provide a similar stiffness and reserve capacity. In order to investigate the potential influence of the range of possible beam-column-gusset plate designs, this paper assesses the effect of the fixity of these connections on the behavior of a six-storey special concentrically braced frame. Nonlinear dynamic analyses have been conducted to determine the seismic performance of the frame with this connection modelled using three different assumptions (pinned, shear tab and fixed), and the collapse risk is assessed using the FEMA P695 methodology. The results show that when the gravity framing is not modelled, the fixity of the beam-column connections is important in avoiding the formation of a soft storey under extreme earthquakes, thereby reducing the probability of collapse of the building.</description><subject>Beam-columns</subject><subject>Collapse</subject><subject>Dynamical systems</subject><subject>Earthquake damage</subject><subject>Earthquakes</subject><subject>Gusset plates</subject><subject>Nonlinear analysis</subject><subject>Nonlinear dynamics</subject><subject>Reinforcement (structures)</subject><subject>Reserve capacity</subject><subject>Seismic design</subject><subject>Seismic engineering</subject><subject>Seismic response</subject><subject>Stiffness</subject><issn>1013-9826</issn><issn>1662-9795</issn><issn>1662-9795</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqNkMFKAzEQhhdRsFbfISB4222y6SbNRbRLq2JFoXoOaTbBlN1kTVLavr0pFXr1NMPwzzfDl2V3CBZjWE5G2-22CNIoG402srAqjl5nbwUluEAVPcsGiJAyZ5RV56mHCOdsUpLL7CqENYQYTVA1yMJMayUjcBpMlejy2rWbzoLaWZvGxlkwNzsT98Adhm0r-qDAh_La-U5YqQ6LAizNLl9G59UeLHsljWgPBJle80aKtt2DqRdSNWDuRaeuswst2qBu_uow-5rPPuvnfPH-9FI_LnJZIkjztEApXAlcNmwssYRwXDVaE62xwA2UBDVUM7kaYz1ZUYwq3DQVaVilVpiUCONhdnvk9t79bFSIfO023qaTvESMQQoJoyl1f0xJ70LwSvPem074PUeQH0TzJJqfRPMkmifRPInmSXQCPBwB0QsbopLfpzv_RPwCJtOQlQ</recordid><startdate>20180201</startdate><enddate>20180201</enddate><creator>Wiebe, Lydell D.A.</creator><creator>Mohsenzadeh, Vahid</creator><general>Trans Tech Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>F28</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20180201</creationdate><title>Effect of Beam-Column Connection Fixity on Collapse Performance of a Six-Storey Special Concentrically Braced Frame</title><author>Wiebe, Lydell D.A. ; Mohsenzadeh, Vahid</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2107-ace770ba32d94c3c0045dff6ff3a3d0c61d7f9cb43f8b73153dd56d95eb362133</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Beam-columns</topic><topic>Collapse</topic><topic>Dynamical systems</topic><topic>Earthquake damage</topic><topic>Earthquakes</topic><topic>Gusset plates</topic><topic>Nonlinear analysis</topic><topic>Nonlinear dynamics</topic><topic>Reinforcement (structures)</topic><topic>Reserve capacity</topic><topic>Seismic design</topic><topic>Seismic engineering</topic><topic>Seismic response</topic><topic>Stiffness</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wiebe, Lydell D.A.</creatorcontrib><creatorcontrib>Mohsenzadeh, Vahid</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>Key engineering materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wiebe, Lydell D.A.</au><au>Mohsenzadeh, Vahid</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of Beam-Column Connection Fixity on Collapse Performance of a Six-Storey Special Concentrically Braced Frame</atitle><jtitle>Key engineering materials</jtitle><date>2018-02-01</date><risdate>2018</risdate><volume>763</volume><spage>157</spage><epage>164</epage><pages>157-164</pages><issn>1013-9826</issn><issn>1662-9795</issn><eissn>1662-9795</eissn><abstract>Concentrically braced frames are one of the most common seismic force resisting systems because of their high strength and stiffness. In current practice, the gusset plates that connect the brace to the adjacent beams and columns can increase the strength and stiffness of the connection significantly. This strength and stiffness can provide a reserve of lateral force resisting capacity during a large earthquake, which may play a role in the seismic collapse behaviour of the braced frame. An alternative connection has recently been proposed as a means of ensuring that brace buckling occurs only in-plane, that no field welding is required, and that all damage is confined to a replaceable brace module. However, the proposed connection does not include a gusset plate that can provide a similar stiffness and reserve capacity. In order to investigate the potential influence of the range of possible beam-column-gusset plate designs, this paper assesses the effect of the fixity of these connections on the behavior of a six-storey special concentrically braced frame. Nonlinear dynamic analyses have been conducted to determine the seismic performance of the frame with this connection modelled using three different assumptions (pinned, shear tab and fixed), and the collapse risk is assessed using the FEMA P695 methodology. The results show that when the gravity framing is not modelled, the fixity of the beam-column connections is important in avoiding the formation of a soft storey under extreme earthquakes, thereby reducing the probability of collapse of the building.</abstract><cop>Zurich</cop><pub>Trans Tech Publications Ltd</pub><doi>10.4028/www.scientific.net/KEM.763.157</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1013-9826 |
ispartof | Key engineering materials, 2018-02, Vol.763, p.157-164 |
issn | 1013-9826 1662-9795 1662-9795 |
language | eng |
recordid | cdi_proquest_journals_2199070697 |
source | Scientific.net Journals |
subjects | Beam-columns Collapse Dynamical systems Earthquake damage Earthquakes Gusset plates Nonlinear analysis Nonlinear dynamics Reinforcement (structures) Reserve capacity Seismic design Seismic engineering Seismic response Stiffness |
title | Effect of Beam-Column Connection Fixity on Collapse Performance of a Six-Storey Special Concentrically Braced Frame |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T20%3A31%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20Beam-Column%20Connection%20Fixity%20on%20Collapse%20Performance%20of%20a%20Six-Storey%20Special%20Concentrically%20Braced%20Frame&rft.jtitle=Key%20engineering%20materials&rft.au=Wiebe,%20Lydell%20D.A.&rft.date=2018-02-01&rft.volume=763&rft.spage=157&rft.epage=164&rft.pages=157-164&rft.issn=1013-9826&rft.eissn=1662-9795&rft_id=info:doi/10.4028/www.scientific.net/KEM.763.157&rft_dat=%3Cproquest_cross%3E2199070697%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2107-ace770ba32d94c3c0045dff6ff3a3d0c61d7f9cb43f8b73153dd56d95eb362133%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2199070697&rft_id=info:pmid/&rfr_iscdi=true |