Loading…

Boosting the rule-out accuracy of deep disease detection using class weight modifiers

In many screening applications, the primary goal of a radiologist or assisting artificial intelligence is to rule out certain findings. The classifiers built for such applications are often trained on large datasets that derive labels from clinical notes written for patients. While the quality of th...

Full description

Saved in:
Bibliographic Details
Published in:arXiv.org 2019-06
Main Authors: Karargyris, Alexandros, Wong, Ken C L, Wu, Joy T, Moradi, Mehdi, Syeda-Mahmood, Tanveer
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Karargyris, Alexandros
Wong, Ken C L
Wu, Joy T
Moradi, Mehdi
Syeda-Mahmood, Tanveer
description In many screening applications, the primary goal of a radiologist or assisting artificial intelligence is to rule out certain findings. The classifiers built for such applications are often trained on large datasets that derive labels from clinical notes written for patients. While the quality of the positive findings described in these notes is often reliable, lack of the mention of a finding does not always rule out the presence of it. This happens because radiologists comment on the patient in the context of the exam, for example focusing on trauma as opposed to chronic disease at emergency rooms. However, this disease finding ambiguity can affect the performance of algorithms. Hence it is critical to model the ambiguity during training. We propose a scheme to apply reasonable class weight modifiers to our loss function for the no mention cases during training. We experiment with two different deep neural network architectures and show that the proposed method results in a large improvement in the performance of the classifiers, specially on negated findings. The baseline performance of a custom-made dilated block network proposed in this paper shows an improvement in comparison with baseline DenseNet-201, while both architectures benefit from the new proposed loss function weighting scheme. Over 200,000 chest X-ray images and three highly common diseases, along with their negated counterparts, are included in this study.
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2246533605</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2246533605</sourcerecordid><originalsourceid>FETCH-proquest_journals_22465336053</originalsourceid><addsrcrecordid>eNqNi0EKwjAQRYMgWLR3GHBdqElTXSuKB9B1Cem0TamdmkkQb28FD-Dq83jvL0Qildplh0LKlUiZ-zzPZbmXWqtE3I9EHNzYQugQfBwwoxjAWBu9sW-gBmrECWrHaBhnCGiDoxEif192MMzwQtd2AR5Uu8ah541YNmZgTH-7FtvL-Xa6ZpOnZ0QOVU_Rj7OqpCxKrVSZa_Vf9QHqKEEm</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2246533605</pqid></control><display><type>article</type><title>Boosting the rule-out accuracy of deep disease detection using class weight modifiers</title><source>Publicly Available Content Database</source><creator>Karargyris, Alexandros ; Wong, Ken C L ; Wu, Joy T ; Moradi, Mehdi ; Syeda-Mahmood, Tanveer</creator><creatorcontrib>Karargyris, Alexandros ; Wong, Ken C L ; Wu, Joy T ; Moradi, Mehdi ; Syeda-Mahmood, Tanveer</creatorcontrib><description>In many screening applications, the primary goal of a radiologist or assisting artificial intelligence is to rule out certain findings. The classifiers built for such applications are often trained on large datasets that derive labels from clinical notes written for patients. While the quality of the positive findings described in these notes is often reliable, lack of the mention of a finding does not always rule out the presence of it. This happens because radiologists comment on the patient in the context of the exam, for example focusing on trauma as opposed to chronic disease at emergency rooms. However, this disease finding ambiguity can affect the performance of algorithms. Hence it is critical to model the ambiguity during training. We propose a scheme to apply reasonable class weight modifiers to our loss function for the no mention cases during training. We experiment with two different deep neural network architectures and show that the proposed method results in a large improvement in the performance of the classifiers, specially on negated findings. The baseline performance of a custom-made dilated block network proposed in this paper shows an improvement in comparison with baseline DenseNet-201, while both architectures benefit from the new proposed loss function weighting scheme. Over 200,000 chest X-ray images and three highly common diseases, along with their negated counterparts, are included in this study.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Algorithms ; Ambiguity ; Artificial intelligence ; Classifiers ; Emergency medical services ; Neural networks ; Training ; Weight</subject><ispartof>arXiv.org, 2019-06</ispartof><rights>2019. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2246533605?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>780,784,25753,37012,44590</link.rule.ids></links><search><creatorcontrib>Karargyris, Alexandros</creatorcontrib><creatorcontrib>Wong, Ken C L</creatorcontrib><creatorcontrib>Wu, Joy T</creatorcontrib><creatorcontrib>Moradi, Mehdi</creatorcontrib><creatorcontrib>Syeda-Mahmood, Tanveer</creatorcontrib><title>Boosting the rule-out accuracy of deep disease detection using class weight modifiers</title><title>arXiv.org</title><description>In many screening applications, the primary goal of a radiologist or assisting artificial intelligence is to rule out certain findings. The classifiers built for such applications are often trained on large datasets that derive labels from clinical notes written for patients. While the quality of the positive findings described in these notes is often reliable, lack of the mention of a finding does not always rule out the presence of it. This happens because radiologists comment on the patient in the context of the exam, for example focusing on trauma as opposed to chronic disease at emergency rooms. However, this disease finding ambiguity can affect the performance of algorithms. Hence it is critical to model the ambiguity during training. We propose a scheme to apply reasonable class weight modifiers to our loss function for the no mention cases during training. We experiment with two different deep neural network architectures and show that the proposed method results in a large improvement in the performance of the classifiers, specially on negated findings. The baseline performance of a custom-made dilated block network proposed in this paper shows an improvement in comparison with baseline DenseNet-201, while both architectures benefit from the new proposed loss function weighting scheme. Over 200,000 chest X-ray images and three highly common diseases, along with their negated counterparts, are included in this study.</description><subject>Algorithms</subject><subject>Ambiguity</subject><subject>Artificial intelligence</subject><subject>Classifiers</subject><subject>Emergency medical services</subject><subject>Neural networks</subject><subject>Training</subject><subject>Weight</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqNi0EKwjAQRYMgWLR3GHBdqElTXSuKB9B1Cem0TamdmkkQb28FD-Dq83jvL0Qildplh0LKlUiZ-zzPZbmXWqtE3I9EHNzYQugQfBwwoxjAWBu9sW-gBmrECWrHaBhnCGiDoxEif192MMzwQtd2AR5Uu8ah541YNmZgTH-7FtvL-Xa6ZpOnZ0QOVU_Rj7OqpCxKrVSZa_Vf9QHqKEEm</recordid><startdate>20190621</startdate><enddate>20190621</enddate><creator>Karargyris, Alexandros</creator><creator>Wong, Ken C L</creator><creator>Wu, Joy T</creator><creator>Moradi, Mehdi</creator><creator>Syeda-Mahmood, Tanveer</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20190621</creationdate><title>Boosting the rule-out accuracy of deep disease detection using class weight modifiers</title><author>Karargyris, Alexandros ; Wong, Ken C L ; Wu, Joy T ; Moradi, Mehdi ; Syeda-Mahmood, Tanveer</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_22465336053</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Algorithms</topic><topic>Ambiguity</topic><topic>Artificial intelligence</topic><topic>Classifiers</topic><topic>Emergency medical services</topic><topic>Neural networks</topic><topic>Training</topic><topic>Weight</topic><toplevel>online_resources</toplevel><creatorcontrib>Karargyris, Alexandros</creatorcontrib><creatorcontrib>Wong, Ken C L</creatorcontrib><creatorcontrib>Wu, Joy T</creatorcontrib><creatorcontrib>Moradi, Mehdi</creatorcontrib><creatorcontrib>Syeda-Mahmood, Tanveer</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Karargyris, Alexandros</au><au>Wong, Ken C L</au><au>Wu, Joy T</au><au>Moradi, Mehdi</au><au>Syeda-Mahmood, Tanveer</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>Boosting the rule-out accuracy of deep disease detection using class weight modifiers</atitle><jtitle>arXiv.org</jtitle><date>2019-06-21</date><risdate>2019</risdate><eissn>2331-8422</eissn><abstract>In many screening applications, the primary goal of a radiologist or assisting artificial intelligence is to rule out certain findings. The classifiers built for such applications are often trained on large datasets that derive labels from clinical notes written for patients. While the quality of the positive findings described in these notes is often reliable, lack of the mention of a finding does not always rule out the presence of it. This happens because radiologists comment on the patient in the context of the exam, for example focusing on trauma as opposed to chronic disease at emergency rooms. However, this disease finding ambiguity can affect the performance of algorithms. Hence it is critical to model the ambiguity during training. We propose a scheme to apply reasonable class weight modifiers to our loss function for the no mention cases during training. We experiment with two different deep neural network architectures and show that the proposed method results in a large improvement in the performance of the classifiers, specially on negated findings. The baseline performance of a custom-made dilated block network proposed in this paper shows an improvement in comparison with baseline DenseNet-201, while both architectures benefit from the new proposed loss function weighting scheme. Over 200,000 chest X-ray images and three highly common diseases, along with their negated counterparts, are included in this study.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2019-06
issn 2331-8422
language eng
recordid cdi_proquest_journals_2246533605
source Publicly Available Content Database
subjects Algorithms
Ambiguity
Artificial intelligence
Classifiers
Emergency medical services
Neural networks
Training
Weight
title Boosting the rule-out accuracy of deep disease detection using class weight modifiers
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T15%3A37%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=Boosting%20the%20rule-out%20accuracy%20of%20deep%20disease%20detection%20using%20class%20weight%20modifiers&rft.jtitle=arXiv.org&rft.au=Karargyris,%20Alexandros&rft.date=2019-06-21&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E2246533605%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_journals_22465336053%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2246533605&rft_id=info:pmid/&rfr_iscdi=true