Loading…
Graded exchange reaming and nailing of non-unions
The effect of graded exchange reaming and intramedullary nailing on a non-union model in the rat femur was studied by clinical, radiological, bone mineralisation and biomechanical methods. A standardised procedure was first developed to create a non-union that did not heal and in which non-union dev...
Saved in:
Published in: | Archives of orthopaedic and trauma surgery 1998-11, Vol.118 (1-2), p.1-6 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c1106-5337e6106a621b64051aec8aed6d4e8e850dc096b03f83fb79042f0ef795e8b03 |
---|---|
cites | |
container_end_page | 6 |
container_issue | 1-2 |
container_start_page | 1 |
container_title | Archives of orthopaedic and trauma surgery |
container_volume | 118 |
creator | Utvåg, S. E. Grundnes, O. Reikerås, O. |
description | The effect of graded exchange reaming and intramedullary nailing on a non-union model in the rat femur was studied by clinical, radiological, bone mineralisation and biomechanical methods. A standardised procedure was first developed to create a non-union that did not heal and in which non-union developed consistently. In 30 male Wistar rats a standardised osteotomy was produced in the left femur diaphysis. The fractures were reamed to 1.5 mm and nailed with a soft polyethylene nail for 12 weeks. After 1 week the fractures were manipulated in bending and rotation every 2nd day for 5 weeks. At 12 weeks radiographs demonstrated a hypertrophic non-union in all fractures, and the rats were randomly divided into three groups. In the control group no reoperation was performed (group C). In group 1.6 exchange reaming to 1.6 mm and medullary nailing were performed, and reaming and nailing to 2.0 mm in group 2.0. The effect of extensive versus modest reaming and nailing on bone repair was then assessed 12 weeks later. Physical examination, radiographs, bone mineralisation measurements by dual energy X-ray absorptiometry (DEXA) and biomechanical femures evaluated by a three-point bending test in a Mini Bionix (MTS) testing system were employed. In the control group radiographs revealed a state of non-union in all fractures, and the mechanical strength was significantly reduced compared with both intervention groups. Bone mineral content (BMC) and bone mineral density (BMD) were reduced in the callus region compared with group 2.0. In the intervention groups radiographs showed various degrees of union. Mechanical testing showed that the fracture energy was significantly higher in group 2.0 than in group 1.6. The finding that extensive exchange reaming and nailing seems favourable in non-unions of diaphyseal fractures compared with modest reaming may have clinical implications. |
doi_str_mv | 10.1007/s004020050300 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2261998776</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2261998776</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1106-5337e6106a621b64051aec8aed6d4e8e850dc096b03f83fb79042f0ef795e8b03</originalsourceid><addsrcrecordid>eNpVkE1LAzEYhIMouFaP3hc8R998bD6OUrQVCl70HLKbN3VLm9TEgv57t9SLpxmGhxkYQm4Z3DMA_VABJHCADgTAGWmYFJIKy9Q5acAKRQ107JJc1boBYNxYaAhbFB8wtPg9fPi0xrag341p3foU2uTH7dHn2Kac6CGNOdVrchH9tuLNn87I-_PT23xJV6-Ll_njig6MgaKdEBrV5LzirFdymvY4GI9BBYkGTQdhAKt6ENGI2GsLkkfAqG2HZkpn5O7Uuy_584D1y23yoaRp0nGumLVGazVR9EQNJddaMLp9GXe-_DgG7viK-_eK-AUGe1IG</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2261998776</pqid></control><display><type>article</type><title>Graded exchange reaming and nailing of non-unions</title><source>Springer Link</source><creator>Utvåg, S. E. ; Grundnes, O. ; Reikerås, O.</creator><creatorcontrib>Utvåg, S. E. ; Grundnes, O. ; Reikerås, O.</creatorcontrib><description>The effect of graded exchange reaming and intramedullary nailing on a non-union model in the rat femur was studied by clinical, radiological, bone mineralisation and biomechanical methods. A standardised procedure was first developed to create a non-union that did not heal and in which non-union developed consistently. In 30 male Wistar rats a standardised osteotomy was produced in the left femur diaphysis. The fractures were reamed to 1.5 mm and nailed with a soft polyethylene nail for 12 weeks. After 1 week the fractures were manipulated in bending and rotation every 2nd day for 5 weeks. At 12 weeks radiographs demonstrated a hypertrophic non-union in all fractures, and the rats were randomly divided into three groups. In the control group no reoperation was performed (group C). In group 1.6 exchange reaming to 1.6 mm and medullary nailing were performed, and reaming and nailing to 2.0 mm in group 2.0. The effect of extensive versus modest reaming and nailing on bone repair was then assessed 12 weeks later. Physical examination, radiographs, bone mineralisation measurements by dual energy X-ray absorptiometry (DEXA) and biomechanical femures evaluated by a three-point bending test in a Mini Bionix (MTS) testing system were employed. In the control group radiographs revealed a state of non-union in all fractures, and the mechanical strength was significantly reduced compared with both intervention groups. Bone mineral content (BMC) and bone mineral density (BMD) were reduced in the callus region compared with group 2.0. In the intervention groups radiographs showed various degrees of union. Mechanical testing showed that the fracture energy was significantly higher in group 2.0 than in group 1.6. The finding that extensive exchange reaming and nailing seems favourable in non-unions of diaphyseal fractures compared with modest reaming may have clinical implications.</description><identifier>ISSN: 0936-8051</identifier><identifier>EISSN: 1434-3916</identifier><identifier>DOI: 10.1007/s004020050300</identifier><language>eng</language><publisher>Heidelberg: Springer Nature B.V</publisher><subject>Biomechanics ; Fractures</subject><ispartof>Archives of orthopaedic and trauma surgery, 1998-11, Vol.118 (1-2), p.1-6</ispartof><rights>Archives of Orthopaedic and Trauma Surgery is a copyright of Springer, (1998). All Rights Reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1106-5337e6106a621b64051aec8aed6d4e8e850dc096b03f83fb79042f0ef795e8b03</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Utvåg, S. E.</creatorcontrib><creatorcontrib>Grundnes, O.</creatorcontrib><creatorcontrib>Reikerås, O.</creatorcontrib><title>Graded exchange reaming and nailing of non-unions</title><title>Archives of orthopaedic and trauma surgery</title><description>The effect of graded exchange reaming and intramedullary nailing on a non-union model in the rat femur was studied by clinical, radiological, bone mineralisation and biomechanical methods. A standardised procedure was first developed to create a non-union that did not heal and in which non-union developed consistently. In 30 male Wistar rats a standardised osteotomy was produced in the left femur diaphysis. The fractures were reamed to 1.5 mm and nailed with a soft polyethylene nail for 12 weeks. After 1 week the fractures were manipulated in bending and rotation every 2nd day for 5 weeks. At 12 weeks radiographs demonstrated a hypertrophic non-union in all fractures, and the rats were randomly divided into three groups. In the control group no reoperation was performed (group C). In group 1.6 exchange reaming to 1.6 mm and medullary nailing were performed, and reaming and nailing to 2.0 mm in group 2.0. The effect of extensive versus modest reaming and nailing on bone repair was then assessed 12 weeks later. Physical examination, radiographs, bone mineralisation measurements by dual energy X-ray absorptiometry (DEXA) and biomechanical femures evaluated by a three-point bending test in a Mini Bionix (MTS) testing system were employed. In the control group radiographs revealed a state of non-union in all fractures, and the mechanical strength was significantly reduced compared with both intervention groups. Bone mineral content (BMC) and bone mineral density (BMD) were reduced in the callus region compared with group 2.0. In the intervention groups radiographs showed various degrees of union. Mechanical testing showed that the fracture energy was significantly higher in group 2.0 than in group 1.6. The finding that extensive exchange reaming and nailing seems favourable in non-unions of diaphyseal fractures compared with modest reaming may have clinical implications.</description><subject>Biomechanics</subject><subject>Fractures</subject><issn>0936-8051</issn><issn>1434-3916</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNpVkE1LAzEYhIMouFaP3hc8R998bD6OUrQVCl70HLKbN3VLm9TEgv57t9SLpxmGhxkYQm4Z3DMA_VABJHCADgTAGWmYFJIKy9Q5acAKRQ107JJc1boBYNxYaAhbFB8wtPg9fPi0xrag341p3foU2uTH7dHn2Kac6CGNOdVrchH9tuLNn87I-_PT23xJV6-Ll_njig6MgaKdEBrV5LzirFdymvY4GI9BBYkGTQdhAKt6ENGI2GsLkkfAqG2HZkpn5O7Uuy_584D1y23yoaRp0nGumLVGazVR9EQNJddaMLp9GXe-_DgG7viK-_eK-AUGe1IG</recordid><startdate>19981102</startdate><enddate>19981102</enddate><creator>Utvåg, S. E.</creator><creator>Grundnes, O.</creator><creator>Reikerås, O.</creator><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>KB0</scope><scope>M0S</scope><scope>NAPCQ</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>19981102</creationdate><title>Graded exchange reaming and nailing of non-unions</title><author>Utvåg, S. E. ; Grundnes, O. ; Reikerås, O.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1106-5337e6106a621b64051aec8aed6d4e8e850dc096b03f83fb79042f0ef795e8b03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Biomechanics</topic><topic>Fractures</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Utvåg, S. E.</creatorcontrib><creatorcontrib>Grundnes, O.</creatorcontrib><creatorcontrib>Reikerås, O.</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing & Allied Health Database</collection><collection>ProQuest - Health & Medical Complete保健、医学与药学数据库</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Database (Alumni Edition)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Nursing & Allied Health Premium</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Archives of orthopaedic and trauma surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Utvåg, S. E.</au><au>Grundnes, O.</au><au>Reikerås, O.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Graded exchange reaming and nailing of non-unions</atitle><jtitle>Archives of orthopaedic and trauma surgery</jtitle><date>1998-11-02</date><risdate>1998</risdate><volume>118</volume><issue>1-2</issue><spage>1</spage><epage>6</epage><pages>1-6</pages><issn>0936-8051</issn><eissn>1434-3916</eissn><abstract>The effect of graded exchange reaming and intramedullary nailing on a non-union model in the rat femur was studied by clinical, radiological, bone mineralisation and biomechanical methods. A standardised procedure was first developed to create a non-union that did not heal and in which non-union developed consistently. In 30 male Wistar rats a standardised osteotomy was produced in the left femur diaphysis. The fractures were reamed to 1.5 mm and nailed with a soft polyethylene nail for 12 weeks. After 1 week the fractures were manipulated in bending and rotation every 2nd day for 5 weeks. At 12 weeks radiographs demonstrated a hypertrophic non-union in all fractures, and the rats were randomly divided into three groups. In the control group no reoperation was performed (group C). In group 1.6 exchange reaming to 1.6 mm and medullary nailing were performed, and reaming and nailing to 2.0 mm in group 2.0. The effect of extensive versus modest reaming and nailing on bone repair was then assessed 12 weeks later. Physical examination, radiographs, bone mineralisation measurements by dual energy X-ray absorptiometry (DEXA) and biomechanical femures evaluated by a three-point bending test in a Mini Bionix (MTS) testing system were employed. In the control group radiographs revealed a state of non-union in all fractures, and the mechanical strength was significantly reduced compared with both intervention groups. Bone mineral content (BMC) and bone mineral density (BMD) were reduced in the callus region compared with group 2.0. In the intervention groups radiographs showed various degrees of union. Mechanical testing showed that the fracture energy was significantly higher in group 2.0 than in group 1.6. The finding that extensive exchange reaming and nailing seems favourable in non-unions of diaphyseal fractures compared with modest reaming may have clinical implications.</abstract><cop>Heidelberg</cop><pub>Springer Nature B.V</pub><doi>10.1007/s004020050300</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0936-8051 |
ispartof | Archives of orthopaedic and trauma surgery, 1998-11, Vol.118 (1-2), p.1-6 |
issn | 0936-8051 1434-3916 |
language | eng |
recordid | cdi_proquest_journals_2261998776 |
source | Springer Link |
subjects | Biomechanics Fractures |
title | Graded exchange reaming and nailing of non-unions |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T08%3A38%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Graded%20exchange%20reaming%20and%20nailing%20of%20non-unions&rft.jtitle=Archives%20of%20orthopaedic%20and%20trauma%20surgery&rft.au=Utv%C3%A5g,%20S.%20E.&rft.date=1998-11-02&rft.volume=118&rft.issue=1-2&rft.spage=1&rft.epage=6&rft.pages=1-6&rft.issn=0936-8051&rft.eissn=1434-3916&rft_id=info:doi/10.1007/s004020050300&rft_dat=%3Cproquest_cross%3E2261998776%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1106-5337e6106a621b64051aec8aed6d4e8e850dc096b03f83fb79042f0ef795e8b03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2261998776&rft_id=info:pmid/&rfr_iscdi=true |