Loading…
Connection status evaluation in arc stud weld joints by ultrasonic detection
Precise mechanical ultrasonic scan detection is used in this study for evaluating the connection status of arc stud weld (ASW) joints. The study reveals the relationship between different connection states of ASW joint and ultrasonic scan eigenvalues in time domain, frequency domain, and time–freque...
Saved in:
Published in: | International journal of advanced manufacturing technology 2019-01, Vol.100 (1-4), p.663-672 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Precise mechanical ultrasonic scan detection is used in this study for evaluating the connection status of arc stud weld (ASW) joints. The study reveals the relationship between different connection states of ASW joint and ultrasonic scan eigenvalues in time domain, frequency domain, and time–frequency domain. The analysis results in time domain and frequency domain show that according to the amplitude of the first echo from the bottom of the steel plate in time domain and the amplitude at the main frequency of 1.25 MHz in frequency domain, the ASW joint can be identified from the base metal. The analysis in time–frequency domain shows that according to the amplitude of the specific high frequency, the weak connection zone can be identified from the ASW joint. This lays a foundation for the identification of ASW joint fusion zone and has positive significance in practical applications. |
---|---|
ISSN: | 0268-3768 1433-3015 |
DOI: | 10.1007/s00170-018-2752-9 |