The ACE1 Electrical Impedance Tomography System for Thoracic Imaging

The design and performance of the active complex electrode (ACE1) electrical impedance tomography system for single-ended phasic voltage measurements are presented. The design of the hardware and calibration procedures allows for reconstruction of conductivity and permittivity images. Phase measurem...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on instrumentation and measurement 2019-09, Vol.68 (9), p.3137-3150
Main Authors: Mellenthin, Michelle M., Mueller, Jennifer L., de Camargo, Erick Dario Leon Bueno, de Moura, Fernando Silva, Santos, Talles Batista Rattis, Lima, Raul Gonzalez, Hamilton, Sarah J., Muller, Peter A., Alsaker, Melody
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c491t-961c167bee5f976bc580000466604803187dc06198a5809978ae64a6d72a4da33
cites cdi_FETCH-LOGICAL-c491t-961c167bee5f976bc580000466604803187dc06198a5809978ae64a6d72a4da33
container_end_page 3150
container_issue 9
container_start_page 3137
container_title IEEE transactions on instrumentation and measurement
container_volume 68
creator Mellenthin, Michelle M.
Mueller, Jennifer L.
de Camargo, Erick Dario Leon Bueno
de Moura, Fernando Silva
Santos, Talles Batista Rattis
Lima, Raul Gonzalez
Hamilton, Sarah J.
Muller, Peter A.
Alsaker, Melody
description The design and performance of the active complex electrode (ACE1) electrical impedance tomography system for single-ended phasic voltage measurements are presented. The design of the hardware and calibration procedures allows for reconstruction of conductivity and permittivity images. Phase measurement is achieved with the ACE1 active electrode circuit which measures the amplitude and phase of the voltage and the applied current at the location at which current is injected into the body. An evaluation of the system performance under typical operating conditions includes details of demodulation and calibration and an in-depth look at insightful metrics, such as signal-to-noise ratio variations during a single current pattern. Static and dynamic images of conductivity and permittivity are presented from ACE1 data collected on tank phantoms and human subjects to illustrate the system's utility.
doi_str_mv 10.1109/TIM.2018.2874127
format article
fullrecord <record><control><sourceid>proquest_ieee_</sourceid><recordid>TN_cdi_proquest_journals_2272002490</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>8519738</ieee_id><sourcerecordid>2463600300</sourcerecordid><originalsourceid>FETCH-LOGICAL-c491t-961c167bee5f976bc580000466604803187dc06198a5809978ae64a6d72a4da33</originalsourceid><addsrcrecordid>eNpdkc1rGzEQxUVJaRy390IhLPSSi93Rx-rjEgiukxpSeuj2LGTt2N6wu3KkdcD_fWXsmKYwMIf3m8cbHiGfKUwpBfOtWvycMqB6yrQSlKl3ZETLUk2MlOyCjCBLEyNKeUmuUnoCACWF-kAuOWeMl5KPyPdqg8XdbE6LeYt-iI13bbHotli73mNRhS6so9tu9sXvfRqwK1YhFtUmROcbn0G3bvr1R_J-5dqEn057TP7cz6vZj8njr4fF7O5x4oWhQ05FPZVqiViujJJLX-ocCYSUEoQGTrWqPUhqtMuKMUo7lMLJWjEnasf5mNwefbe7ZYe1x36IrrXb2HQu7m1wjX2r9M3GrsOLVVJpxWQ2uDkZxPC8wzTYrkke29b1GHbJMiG5BOB5xuTrf-hT2MU-v2cZUwyACXOg4Ej5GFKKuDqHoWAPFdlckT1UZE8V5ZPrf584H7x2koEvR6BBxLOsS2oU1_wvG56Suw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2272002490</pqid></control><display><type>article</type><title>The ACE1 Electrical Impedance Tomography System for Thoracic Imaging</title><source>IEEE Electronic Library (IEL) Journals</source><creator>Mellenthin, Michelle M. ; Mueller, Jennifer L. ; de Camargo, Erick Dario Leon Bueno ; de Moura, Fernando Silva ; Santos, Talles Batista Rattis ; Lima, Raul Gonzalez ; Hamilton, Sarah J. ; Muller, Peter A. ; Alsaker, Melody</creator><creatorcontrib>Mellenthin, Michelle M. ; Mueller, Jennifer L. ; de Camargo, Erick Dario Leon Bueno ; de Moura, Fernando Silva ; Santos, Talles Batista Rattis ; Lima, Raul Gonzalez ; Hamilton, Sarah J. ; Muller, Peter A. ; Alsaker, Melody</creatorcontrib><description>The design and performance of the active complex electrode (ACE1) electrical impedance tomography system for single-ended phasic voltage measurements are presented. The design of the hardware and calibration procedures allows for reconstruction of conductivity and permittivity images. Phase measurement is achieved with the ACE1 active electrode circuit which measures the amplitude and phase of the voltage and the applied current at the location at which current is injected into the body. An evaluation of the system performance under typical operating conditions includes details of demodulation and calibration and an in-depth look at insightful metrics, such as signal-to-noise ratio variations during a single current pattern. Static and dynamic images of conductivity and permittivity are presented from ACE1 data collected on tank phantoms and human subjects to illustrate the system's utility.</description><identifier>ISSN: 0018-9456</identifier><identifier>EISSN: 1557-9662</identifier><identifier>DOI: 10.1109/TIM.2018.2874127</identifier><identifier>PMID: 33223563</identifier><identifier>CODEN: IEIMAO</identifier><language>eng</language><publisher>United States: IEEE</publisher><subject>Biomedical imaging ; Calibration ; Circuits ; Current measurement ; Demodulation ; Electrical impedance ; electrical impedance tomography (EIT) ; Electrical measurement ; Electrical resistivity ; Electrodes ; Image reconstruction ; Impedance ; Permittivity ; Phase measurement ; Signal to noise ratio ; thoracic imaging ; Tomography ; Voltage measurement</subject><ispartof>IEEE transactions on instrumentation and measurement, 2019-09, Vol.68 (9), p.3137-3150</ispartof><rights>Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c491t-961c167bee5f976bc580000466604803187dc06198a5809978ae64a6d72a4da33</citedby><cites>FETCH-LOGICAL-c491t-961c167bee5f976bc580000466604803187dc06198a5809978ae64a6d72a4da33</cites><orcidid>0000-0002-2583-5771</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/8519738$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>230,314,776,780,881,27901,27902,54771</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33223563$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mellenthin, Michelle M.</creatorcontrib><creatorcontrib>Mueller, Jennifer L.</creatorcontrib><creatorcontrib>de Camargo, Erick Dario Leon Bueno</creatorcontrib><creatorcontrib>de Moura, Fernando Silva</creatorcontrib><creatorcontrib>Santos, Talles Batista Rattis</creatorcontrib><creatorcontrib>Lima, Raul Gonzalez</creatorcontrib><creatorcontrib>Hamilton, Sarah J.</creatorcontrib><creatorcontrib>Muller, Peter A.</creatorcontrib><creatorcontrib>Alsaker, Melody</creatorcontrib><title>The ACE1 Electrical Impedance Tomography System for Thoracic Imaging</title><title>IEEE transactions on instrumentation and measurement</title><addtitle>TIM</addtitle><addtitle>IEEE Trans Instrum Meas</addtitle><description>The design and performance of the active complex electrode (ACE1) electrical impedance tomography system for single-ended phasic voltage measurements are presented. The design of the hardware and calibration procedures allows for reconstruction of conductivity and permittivity images. Phase measurement is achieved with the ACE1 active electrode circuit which measures the amplitude and phase of the voltage and the applied current at the location at which current is injected into the body. An evaluation of the system performance under typical operating conditions includes details of demodulation and calibration and an in-depth look at insightful metrics, such as signal-to-noise ratio variations during a single current pattern. Static and dynamic images of conductivity and permittivity are presented from ACE1 data collected on tank phantoms and human subjects to illustrate the system's utility.</description><subject>Biomedical imaging</subject><subject>Calibration</subject><subject>Circuits</subject><subject>Current measurement</subject><subject>Demodulation</subject><subject>Electrical impedance</subject><subject>electrical impedance tomography (EIT)</subject><subject>Electrical measurement</subject><subject>Electrical resistivity</subject><subject>Electrodes</subject><subject>Image reconstruction</subject><subject>Impedance</subject><subject>Permittivity</subject><subject>Phase measurement</subject><subject>Signal to noise ratio</subject><subject>thoracic imaging</subject><subject>Tomography</subject><subject>Voltage measurement</subject><issn>0018-9456</issn><issn>1557-9662</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpdkc1rGzEQxUVJaRy390IhLPSSi93Rx-rjEgiukxpSeuj2LGTt2N6wu3KkdcD_fWXsmKYwMIf3m8cbHiGfKUwpBfOtWvycMqB6yrQSlKl3ZETLUk2MlOyCjCBLEyNKeUmuUnoCACWF-kAuOWeMl5KPyPdqg8XdbE6LeYt-iI13bbHotli73mNRhS6so9tu9sXvfRqwK1YhFtUmROcbn0G3bvr1R_J-5dqEn057TP7cz6vZj8njr4fF7O5x4oWhQ05FPZVqiViujJJLX-ocCYSUEoQGTrWqPUhqtMuKMUo7lMLJWjEnasf5mNwefbe7ZYe1x36IrrXb2HQu7m1wjX2r9M3GrsOLVVJpxWQ2uDkZxPC8wzTYrkke29b1GHbJMiG5BOB5xuTrf-hT2MU-v2cZUwyACXOg4Ej5GFKKuDqHoWAPFdlckT1UZE8V5ZPrf584H7x2koEvR6BBxLOsS2oU1_wvG56Suw</recordid><startdate>20190901</startdate><enddate>20190901</enddate><creator>Mellenthin, Michelle M.</creator><creator>Mueller, Jennifer L.</creator><creator>de Camargo, Erick Dario Leon Bueno</creator><creator>de Moura, Fernando Silva</creator><creator>Santos, Talles Batista Rattis</creator><creator>Lima, Raul Gonzalez</creator><creator>Hamilton, Sarah J.</creator><creator>Muller, Peter A.</creator><creator>Alsaker, Melody</creator><general>IEEE</general><general>The Institute of Electrical and Electronics Engineers, Inc. (IEEE)</general><scope>97E</scope><scope>RIA</scope><scope>RIE</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-2583-5771</orcidid></search><sort><creationdate>20190901</creationdate><title>The ACE1 Electrical Impedance Tomography System for Thoracic Imaging</title><author>Mellenthin, Michelle M. ; Mueller, Jennifer L. ; de Camargo, Erick Dario Leon Bueno ; de Moura, Fernando Silva ; Santos, Talles Batista Rattis ; Lima, Raul Gonzalez ; Hamilton, Sarah J. ; Muller, Peter A. ; Alsaker, Melody</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c491t-961c167bee5f976bc580000466604803187dc06198a5809978ae64a6d72a4da33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Biomedical imaging</topic><topic>Calibration</topic><topic>Circuits</topic><topic>Current measurement</topic><topic>Demodulation</topic><topic>Electrical impedance</topic><topic>electrical impedance tomography (EIT)</topic><topic>Electrical measurement</topic><topic>Electrical resistivity</topic><topic>Electrodes</topic><topic>Image reconstruction</topic><topic>Impedance</topic><topic>Permittivity</topic><topic>Phase measurement</topic><topic>Signal to noise ratio</topic><topic>thoracic imaging</topic><topic>Tomography</topic><topic>Voltage measurement</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mellenthin, Michelle M.</creatorcontrib><creatorcontrib>Mueller, Jennifer L.</creatorcontrib><creatorcontrib>de Camargo, Erick Dario Leon Bueno</creatorcontrib><creatorcontrib>de Moura, Fernando Silva</creatorcontrib><creatorcontrib>Santos, Talles Batista Rattis</creatorcontrib><creatorcontrib>Lima, Raul Gonzalez</creatorcontrib><creatorcontrib>Hamilton, Sarah J.</creatorcontrib><creatorcontrib>Muller, Peter A.</creatorcontrib><creatorcontrib>Alsaker, Melody</creatorcontrib><collection>IEEE All-Society Periodicals Package (ASPP) 2005-present</collection><collection>IEEE All-Society Periodicals Package (ASPP) 1998–Present</collection><collection>IEEE Electronic Library (IEL)</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>IEEE transactions on instrumentation and measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mellenthin, Michelle M.</au><au>Mueller, Jennifer L.</au><au>de Camargo, Erick Dario Leon Bueno</au><au>de Moura, Fernando Silva</au><au>Santos, Talles Batista Rattis</au><au>Lima, Raul Gonzalez</au><au>Hamilton, Sarah J.</au><au>Muller, Peter A.</au><au>Alsaker, Melody</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The ACE1 Electrical Impedance Tomography System for Thoracic Imaging</atitle><jtitle>IEEE transactions on instrumentation and measurement</jtitle><stitle>TIM</stitle><addtitle>IEEE Trans Instrum Meas</addtitle><date>2019-09-01</date><risdate>2019</risdate><volume>68</volume><issue>9</issue><spage>3137</spage><epage>3150</epage><pages>3137-3150</pages><issn>0018-9456</issn><eissn>1557-9662</eissn><coden>IEIMAO</coden><abstract>The design and performance of the active complex electrode (ACE1) electrical impedance tomography system for single-ended phasic voltage measurements are presented. The design of the hardware and calibration procedures allows for reconstruction of conductivity and permittivity images. Phase measurement is achieved with the ACE1 active electrode circuit which measures the amplitude and phase of the voltage and the applied current at the location at which current is injected into the body. An evaluation of the system performance under typical operating conditions includes details of demodulation and calibration and an in-depth look at insightful metrics, such as signal-to-noise ratio variations during a single current pattern. Static and dynamic images of conductivity and permittivity are presented from ACE1 data collected on tank phantoms and human subjects to illustrate the system's utility.</abstract><cop>United States</cop><pub>IEEE</pub><pmid>33223563</pmid><doi>10.1109/TIM.2018.2874127</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0002-2583-5771</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0018-9456
ispartof IEEE transactions on instrumentation and measurement, 2019-09, Vol.68 (9), p.3137-3150
issn 0018-9456
1557-9662
language eng
recordid cdi_proquest_journals_2272002490
source IEEE Electronic Library (IEL) Journals
subjects Biomedical imaging
Calibration
Circuits
Current measurement
Demodulation
Electrical impedance
electrical impedance tomography (EIT)
Electrical measurement
Electrical resistivity
Electrodes
Image reconstruction
Impedance
Permittivity
Phase measurement
Signal to noise ratio
thoracic imaging
Tomography
Voltage measurement
title The ACE1 Electrical Impedance Tomography System for Thoracic Imaging
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T20%3A13%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_ieee_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20ACE1%20Electrical%20Impedance%20Tomography%20System%20for%20Thoracic%20Imaging&rft.jtitle=IEEE%20transactions%20on%20instrumentation%20and%20measurement&rft.au=Mellenthin,%20Michelle%20M.&rft.date=2019-09-01&rft.volume=68&rft.issue=9&rft.spage=3137&rft.epage=3150&rft.pages=3137-3150&rft.issn=0018-9456&rft.eissn=1557-9662&rft.coden=IEIMAO&rft_id=info:doi/10.1109/TIM.2018.2874127&rft_dat=%3Cproquest_ieee_%3E2463600300%3C/proquest_ieee_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c491t-961c167bee5f976bc580000466604803187dc06198a5809978ae64a6d72a4da33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2272002490&rft_id=info:pmid/33223563&rft_ieee_id=8519738&rfr_iscdi=true