Effect of thermal interference on energy piles considering various configurations of heat exchangers

•Thermal performance of energy pile systems was evaluated by performing field tests and numerical simulations.•The effect of thermal interference on the thermal behavior of energy piles was investigated.•A design chart for considering the thermal interference effect depending on the denseness of hea...

Full description

Saved in:
Bibliographic Details
Published in:Energy and buildings 2019-09, Vol.199, p.381-401
Main Authors: Park, Sangwoo, Lee, Seokjae, Lee, Dongseop, Ahn, Dongwook, Choi, Hangseok
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•Thermal performance of energy pile systems was evaluated by performing field tests and numerical simulations.•The effect of thermal interference on the thermal behavior of energy piles was investigated.•A design chart for considering the thermal interference effect depending on the denseness of heat exchange pipes was provided. In general, the design of closed-loop vertical ground heat exchangers (GHEXs) is to determine the required borehole length for providing the heating and cooling load of a target building. However, the same design procedure cannot be applied to the cast-in-place energy pile since the configuration of the heat exchange pipe inside the pile is too varied and the size of the borehole is relatively large. In this paper, the effect of configuration and denseness of heat exchange pipe inside the energy pile was experimentally and numerically evaluated comparing with conventional GHEXs. First, field experiments were performed for six cast-in-place energy piles constructed in a test bed. The results showed that the cast-in-place energy piles could provide higher thermal performance per unit borehole length than the other conventional types of GHEXs by increasing the heat exchange area along with much longer heat exchange pipes. However, the over-tight layout diminished the improvement of thermal performance due to thermal interference between each pipe loop. In addition, the long-term thermal behavior of energy piles and changes in ground temperature were estimated with numerical simulations. With the simulation results, a design chart was provided for evaluating the effect of thermal interference on energy pile performance.
ISSN:0378-7788
1872-6178