Loading…

Plasma Profiling Time-of-Flight Mass Spectrometry for Fast Elemental Analysis of Semiconductor Structures with Depth Resolution in the Nanometer Range

Plasma profiling time of flight mass spectrometry (PP-TOFMS) has recently gained interest, as it enables the elemental profiling of semiconductor structures with high depth resolution in short acquisition times. As recently shown by Tempez et al., PP-TOFMS can be used to obtain the composition in th...

Full description

Saved in:
Bibliographic Details
Published in:arXiv.org 2019-12
Main Authors: Spende, Hendrik, Margenfeld, Christoph, Meyer, Tobias, Irene Manglano Clavero, Bremers, Heiko, Hangleiter, Andreas, Seibt, Michael, Waag, Andreas, Bakin, Andrey
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Spende, Hendrik
Margenfeld, Christoph
Meyer, Tobias
Irene Manglano Clavero
Bremers, Heiko
Hangleiter, Andreas
Seibt, Michael
Waag, Andreas
Bakin, Andrey
description Plasma profiling time of flight mass spectrometry (PP-TOFMS) has recently gained interest, as it enables the elemental profiling of semiconductor structures with high depth resolution in short acquisition times. As recently shown by Tempez et al., PP-TOFMS can be used to obtain the composition in the structures for modern field effect transistors [1]. There, the results were compared to conventional SIMS measurements. In the present study, we compare PP-TOFMS measurements of an Al-/In-/GaN quantum well multi stack to established micro- and nano-analysis techniques like cathodoluminescence (CL), scanning transmission electron microscopy (STEM), energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). We show that PP-TOFMS is able to resolve the layer structure of the sample even more than 500 nm deep into the sample and allows the determination of a relative elemental composition with an accuracy of about 10 rel. %. Therefore, it is an extremely rapid alternative method to obtain semiconductor elemental depth profiles without expensive and time consuming sample preparation as it is needed for TEM. Besides, PP-TOFMS offers better depth resolution and more elemental information than for example electrochemical capacitance-voltage (ECV), as the acquisition of all elements occurs in parallel and not only electrically (ECV) or optically (CL) active elements are observed.
doi_str_mv 10.48550/arxiv.1909.12779
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2299324378</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2299324378</sourcerecordid><originalsourceid>FETCH-LOGICAL-a528-240bc6a60d04a62bce7abe2e8cd6bb3bd42d873893632fc05c145e2c5fb09ea43</originalsourceid><addsrcrecordid>eNotj8tOwzAURCMkJKrSD2BniXWKc23nsaxKC0g8qrb7ynFuWleOXWwH6I_wvQTBZmYWR0eaJLnJ6JSXQtA76b_0xzSraDXNoCiqi2QEjGVpyQGukkkIR0op5AUIwUbJ98rI0Emy8q7VRts92eoOU9emS6P3h0heZAhkc0IVvesw-jNpnSdLGSJZGOzQRmnIzEpzDjoQ15INdlo52_QqDuAm-mH0HgP51PFA7vE05BqDM33UzhJtSTwgeZX2V4-erKXd43Vy2UoTcPLf42S7XGznj-nz28PTfPacSgFlCpzWKpc5bSiXOdQKC1kjYKmavK5Z3XBoyoKVFcsZtIoKlXGBoERb0wolZ-Pk9k978u69xxB3R9f74UzYAVQVA86Kkv0Ax-Zrcg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2299324378</pqid></control><display><type>article</type><title>Plasma Profiling Time-of-Flight Mass Spectrometry for Fast Elemental Analysis of Semiconductor Structures with Depth Resolution in the Nanometer Range</title><source>Access via ProQuest (Open Access)</source><creator>Spende, Hendrik ; Margenfeld, Christoph ; Meyer, Tobias ; Irene Manglano Clavero ; Bremers, Heiko ; Hangleiter, Andreas ; Seibt, Michael ; Waag, Andreas ; Bakin, Andrey</creator><creatorcontrib>Spende, Hendrik ; Margenfeld, Christoph ; Meyer, Tobias ; Irene Manglano Clavero ; Bremers, Heiko ; Hangleiter, Andreas ; Seibt, Michael ; Waag, Andreas ; Bakin, Andrey</creatorcontrib><description>Plasma profiling time of flight mass spectrometry (PP-TOFMS) has recently gained interest, as it enables the elemental profiling of semiconductor structures with high depth resolution in short acquisition times. As recently shown by Tempez et al., PP-TOFMS can be used to obtain the composition in the structures for modern field effect transistors [1]. There, the results were compared to conventional SIMS measurements. In the present study, we compare PP-TOFMS measurements of an Al-/In-/GaN quantum well multi stack to established micro- and nano-analysis techniques like cathodoluminescence (CL), scanning transmission electron microscopy (STEM), energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). We show that PP-TOFMS is able to resolve the layer structure of the sample even more than 500 nm deep into the sample and allows the determination of a relative elemental composition with an accuracy of about 10 rel. %. Therefore, it is an extremely rapid alternative method to obtain semiconductor elemental depth profiles without expensive and time consuming sample preparation as it is needed for TEM. Besides, PP-TOFMS offers better depth resolution and more elemental information than for example electrochemical capacitance-voltage (ECV), as the acquisition of all elements occurs in parallel and not only electrically (ECV) or optically (CL) active elements are observed.</description><identifier>EISSN: 2331-8422</identifier><identifier>DOI: 10.48550/arxiv.1909.12779</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Cathodoluminescence ; Composition ; Depth profiling ; Energy transmission ; Field effect transistors ; Gallium nitrides ; Ions ; Mass spectrometry ; Quantum wells ; Scanning transmission electron microscopy ; Scientific imaging ; Semiconductor devices ; Spectroscopy</subject><ispartof>arXiv.org, 2019-12</ispartof><rights>2019. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2299324378?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>780,784,25753,27925,37012,44590</link.rule.ids></links><search><creatorcontrib>Spende, Hendrik</creatorcontrib><creatorcontrib>Margenfeld, Christoph</creatorcontrib><creatorcontrib>Meyer, Tobias</creatorcontrib><creatorcontrib>Irene Manglano Clavero</creatorcontrib><creatorcontrib>Bremers, Heiko</creatorcontrib><creatorcontrib>Hangleiter, Andreas</creatorcontrib><creatorcontrib>Seibt, Michael</creatorcontrib><creatorcontrib>Waag, Andreas</creatorcontrib><creatorcontrib>Bakin, Andrey</creatorcontrib><title>Plasma Profiling Time-of-Flight Mass Spectrometry for Fast Elemental Analysis of Semiconductor Structures with Depth Resolution in the Nanometer Range</title><title>arXiv.org</title><description>Plasma profiling time of flight mass spectrometry (PP-TOFMS) has recently gained interest, as it enables the elemental profiling of semiconductor structures with high depth resolution in short acquisition times. As recently shown by Tempez et al., PP-TOFMS can be used to obtain the composition in the structures for modern field effect transistors [1]. There, the results were compared to conventional SIMS measurements. In the present study, we compare PP-TOFMS measurements of an Al-/In-/GaN quantum well multi stack to established micro- and nano-analysis techniques like cathodoluminescence (CL), scanning transmission electron microscopy (STEM), energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). We show that PP-TOFMS is able to resolve the layer structure of the sample even more than 500 nm deep into the sample and allows the determination of a relative elemental composition with an accuracy of about 10 rel. %. Therefore, it is an extremely rapid alternative method to obtain semiconductor elemental depth profiles without expensive and time consuming sample preparation as it is needed for TEM. Besides, PP-TOFMS offers better depth resolution and more elemental information than for example electrochemical capacitance-voltage (ECV), as the acquisition of all elements occurs in parallel and not only electrically (ECV) or optically (CL) active elements are observed.</description><subject>Cathodoluminescence</subject><subject>Composition</subject><subject>Depth profiling</subject><subject>Energy transmission</subject><subject>Field effect transistors</subject><subject>Gallium nitrides</subject><subject>Ions</subject><subject>Mass spectrometry</subject><subject>Quantum wells</subject><subject>Scanning transmission electron microscopy</subject><subject>Scientific imaging</subject><subject>Semiconductor devices</subject><subject>Spectroscopy</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNotj8tOwzAURCMkJKrSD2BniXWKc23nsaxKC0g8qrb7ynFuWleOXWwH6I_wvQTBZmYWR0eaJLnJ6JSXQtA76b_0xzSraDXNoCiqi2QEjGVpyQGukkkIR0op5AUIwUbJ98rI0Emy8q7VRts92eoOU9emS6P3h0heZAhkc0IVvesw-jNpnSdLGSJZGOzQRmnIzEpzDjoQ15INdlo52_QqDuAm-mH0HgP51PFA7vE05BqDM33UzhJtSTwgeZX2V4-erKXd43Vy2UoTcPLf42S7XGznj-nz28PTfPacSgFlCpzWKpc5bSiXOdQKC1kjYKmavK5Z3XBoyoKVFcsZtIoKlXGBoERb0wolZ-Pk9k978u69xxB3R9f74UzYAVQVA86Kkv0Ax-Zrcg</recordid><startdate>20191202</startdate><enddate>20191202</enddate><creator>Spende, Hendrik</creator><creator>Margenfeld, Christoph</creator><creator>Meyer, Tobias</creator><creator>Irene Manglano Clavero</creator><creator>Bremers, Heiko</creator><creator>Hangleiter, Andreas</creator><creator>Seibt, Michael</creator><creator>Waag, Andreas</creator><creator>Bakin, Andrey</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20191202</creationdate><title>Plasma Profiling Time-of-Flight Mass Spectrometry for Fast Elemental Analysis of Semiconductor Structures with Depth Resolution in the Nanometer Range</title><author>Spende, Hendrik ; Margenfeld, Christoph ; Meyer, Tobias ; Irene Manglano Clavero ; Bremers, Heiko ; Hangleiter, Andreas ; Seibt, Michael ; Waag, Andreas ; Bakin, Andrey</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a528-240bc6a60d04a62bce7abe2e8cd6bb3bd42d873893632fc05c145e2c5fb09ea43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Cathodoluminescence</topic><topic>Composition</topic><topic>Depth profiling</topic><topic>Energy transmission</topic><topic>Field effect transistors</topic><topic>Gallium nitrides</topic><topic>Ions</topic><topic>Mass spectrometry</topic><topic>Quantum wells</topic><topic>Scanning transmission electron microscopy</topic><topic>Scientific imaging</topic><topic>Semiconductor devices</topic><topic>Spectroscopy</topic><toplevel>online_resources</toplevel><creatorcontrib>Spende, Hendrik</creatorcontrib><creatorcontrib>Margenfeld, Christoph</creatorcontrib><creatorcontrib>Meyer, Tobias</creatorcontrib><creatorcontrib>Irene Manglano Clavero</creatorcontrib><creatorcontrib>Bremers, Heiko</creatorcontrib><creatorcontrib>Hangleiter, Andreas</creatorcontrib><creatorcontrib>Seibt, Michael</creatorcontrib><creatorcontrib>Waag, Andreas</creatorcontrib><creatorcontrib>Bakin, Andrey</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>arXiv.org</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Spende, Hendrik</au><au>Margenfeld, Christoph</au><au>Meyer, Tobias</au><au>Irene Manglano Clavero</au><au>Bremers, Heiko</au><au>Hangleiter, Andreas</au><au>Seibt, Michael</au><au>Waag, Andreas</au><au>Bakin, Andrey</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Plasma Profiling Time-of-Flight Mass Spectrometry for Fast Elemental Analysis of Semiconductor Structures with Depth Resolution in the Nanometer Range</atitle><jtitle>arXiv.org</jtitle><date>2019-12-02</date><risdate>2019</risdate><eissn>2331-8422</eissn><abstract>Plasma profiling time of flight mass spectrometry (PP-TOFMS) has recently gained interest, as it enables the elemental profiling of semiconductor structures with high depth resolution in short acquisition times. As recently shown by Tempez et al., PP-TOFMS can be used to obtain the composition in the structures for modern field effect transistors [1]. There, the results were compared to conventional SIMS measurements. In the present study, we compare PP-TOFMS measurements of an Al-/In-/GaN quantum well multi stack to established micro- and nano-analysis techniques like cathodoluminescence (CL), scanning transmission electron microscopy (STEM), energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD). We show that PP-TOFMS is able to resolve the layer structure of the sample even more than 500 nm deep into the sample and allows the determination of a relative elemental composition with an accuracy of about 10 rel. %. Therefore, it is an extremely rapid alternative method to obtain semiconductor elemental depth profiles without expensive and time consuming sample preparation as it is needed for TEM. Besides, PP-TOFMS offers better depth resolution and more elemental information than for example electrochemical capacitance-voltage (ECV), as the acquisition of all elements occurs in parallel and not only electrically (ECV) or optically (CL) active elements are observed.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><doi>10.48550/arxiv.1909.12779</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2019-12
issn 2331-8422
language eng
recordid cdi_proquest_journals_2299324378
source Access via ProQuest (Open Access)
subjects Cathodoluminescence
Composition
Depth profiling
Energy transmission
Field effect transistors
Gallium nitrides
Ions
Mass spectrometry
Quantum wells
Scanning transmission electron microscopy
Scientific imaging
Semiconductor devices
Spectroscopy
title Plasma Profiling Time-of-Flight Mass Spectrometry for Fast Elemental Analysis of Semiconductor Structures with Depth Resolution in the Nanometer Range
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T18%3A22%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Plasma%20Profiling%20Time-of-Flight%20Mass%20Spectrometry%20for%20Fast%20Elemental%20Analysis%20of%20Semiconductor%20Structures%20with%20Depth%20Resolution%20in%20the%20Nanometer%20Range&rft.jtitle=arXiv.org&rft.au=Spende,%20Hendrik&rft.date=2019-12-02&rft.eissn=2331-8422&rft_id=info:doi/10.48550/arxiv.1909.12779&rft_dat=%3Cproquest%3E2299324378%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a528-240bc6a60d04a62bce7abe2e8cd6bb3bd42d873893632fc05c145e2c5fb09ea43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2299324378&rft_id=info:pmid/&rfr_iscdi=true