Loading…
RESEARCHES ON THE MEASUREMENT OF THE DISSOLVED OXYGEN CONCENTRATION IN STATIONARY WATERS
The paper presents methods for measuring the dissolved oxygen concentration in water; the electrical method is presented by presenting an experimental installation designed and built in the laboratories of POLITEHNICA University in Bucharest. For the creation of fine air bubbles, a bubble generator...
Saved in:
Published in: | International Journal of Mechatronics & Applied Mechanics 2018-07, Vol.1 (3), p.120-126 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 126 |
container_issue | 3 |
container_start_page | 120 |
container_title | International Journal of Mechatronics & Applied Mechanics |
container_volume | 1 |
creator | Gheorghe, Gheorghe I Donțu, Octavian Băran, Nicolae Moga, Corina Constantin, Mihaela Tămășanu, Eugen |
description | The paper presents methods for measuring the dissolved oxygen concentration in water; the electrical method is presented by presenting an experimental installation designed and built in the laboratories of POLITEHNICA University in Bucharest. For the creation of fine air bubbles, a bubble generator with 0.1 mm orifices processed by spark-erosion was used. The results of the experimental researches on the measurement of dissolved oxygen in water are presented. |
doi_str_mv | 10.17683/ijomam/issue3.16 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2305779794</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2305779794</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1136-94472ced6d705d6d2dfdb0c3cc225384e195706ddcbbf566f7730718e03590693</originalsourceid><addsrcrecordid>eNotkE9rwkAQxZfSQsX6AXpb6Dm6_9c9hrhqQBPIxlZPi242oNTGZuvBb99gvMw83ryZgR8A7xiNsRRTOjmemvP-PDmGcPV0jMUTGBDOVSSYks8PzaiSr2AUwgkhRBTrPDkA20IbHRfJUhuYZ7BcarjWsdkUeq2zEubzuzVLjclXn3oG8-1uoTOY5FnSzYu4TLutNIOmvMu42MGvuNSFeQMv9f47-NGjD8FmrstkGa3yRZrEq8hhTEWkGJPE-UpUEvGukqquDshR5wjhdMo8VlwiUVXucKi5ELWUFEk89YhyhYSiQ_DR3720ze_Vhz97aq7tT_fSEoq4lEoq1qVwn3JtE0Lra3tpj-d9e7MY2TtD2zO0PUOLBf0HldJfnA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2305779794</pqid></control><display><type>article</type><title>RESEARCHES ON THE MEASUREMENT OF THE DISSOLVED OXYGEN CONCENTRATION IN STATIONARY WATERS</title><source>Publicly Available Content Database</source><creator>Gheorghe, Gheorghe I ; Donțu, Octavian ; Băran, Nicolae ; Moga, Corina ; Constantin, Mihaela ; Tămășanu, Eugen</creator><creatorcontrib>Gheorghe, Gheorghe I ; Donțu, Octavian ; Băran, Nicolae ; Moga, Corina ; Constantin, Mihaela ; Tămășanu, Eugen</creatorcontrib><description>The paper presents methods for measuring the dissolved oxygen concentration in water; the electrical method is presented by presenting an experimental installation designed and built in the laboratories of POLITEHNICA University in Bucharest. For the creation of fine air bubbles, a bubble generator with 0.1 mm orifices processed by spark-erosion was used. The results of the experimental researches on the measurement of dissolved oxygen in water are presented.</description><identifier>ISSN: 2559-4397</identifier><identifier>EISSN: 2559-6497</identifier><identifier>DOI: 10.17683/ijomam/issue3.16</identifier><language>eng</language><publisher>Bucharest: Editura Cefin</publisher><subject>Air bubbles ; Electrodes ; Electrolytes ; Engineering ; Erosion mechanisms ; Generators ; Laboratories ; Measurement methods ; Methods ; Microprocessors ; Orifices ; Oxygen ; Water quality ; Water temperature</subject><ispartof>International Journal of Mechatronics & Applied Mechanics, 2018-07, Vol.1 (3), p.120-126</ispartof><rights>2018. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the associated terms available at https://ijomam.com</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2305779794/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2305779794?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590,75126</link.rule.ids></links><search><creatorcontrib>Gheorghe, Gheorghe I</creatorcontrib><creatorcontrib>Donțu, Octavian</creatorcontrib><creatorcontrib>Băran, Nicolae</creatorcontrib><creatorcontrib>Moga, Corina</creatorcontrib><creatorcontrib>Constantin, Mihaela</creatorcontrib><creatorcontrib>Tămășanu, Eugen</creatorcontrib><title>RESEARCHES ON THE MEASUREMENT OF THE DISSOLVED OXYGEN CONCENTRATION IN STATIONARY WATERS</title><title>International Journal of Mechatronics & Applied Mechanics</title><description>The paper presents methods for measuring the dissolved oxygen concentration in water; the electrical method is presented by presenting an experimental installation designed and built in the laboratories of POLITEHNICA University in Bucharest. For the creation of fine air bubbles, a bubble generator with 0.1 mm orifices processed by spark-erosion was used. The results of the experimental researches on the measurement of dissolved oxygen in water are presented.</description><subject>Air bubbles</subject><subject>Electrodes</subject><subject>Electrolytes</subject><subject>Engineering</subject><subject>Erosion mechanisms</subject><subject>Generators</subject><subject>Laboratories</subject><subject>Measurement methods</subject><subject>Methods</subject><subject>Microprocessors</subject><subject>Orifices</subject><subject>Oxygen</subject><subject>Water quality</subject><subject>Water temperature</subject><issn>2559-4397</issn><issn>2559-6497</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNotkE9rwkAQxZfSQsX6AXpb6Dm6_9c9hrhqQBPIxlZPi242oNTGZuvBb99gvMw83ryZgR8A7xiNsRRTOjmemvP-PDmGcPV0jMUTGBDOVSSYks8PzaiSr2AUwgkhRBTrPDkA20IbHRfJUhuYZ7BcarjWsdkUeq2zEubzuzVLjclXn3oG8-1uoTOY5FnSzYu4TLutNIOmvMu42MGvuNSFeQMv9f47-NGjD8FmrstkGa3yRZrEq8hhTEWkGJPE-UpUEvGukqquDshR5wjhdMo8VlwiUVXucKi5ELWUFEk89YhyhYSiQ_DR3720ze_Vhz97aq7tT_fSEoq4lEoq1qVwn3JtE0Lra3tpj-d9e7MY2TtD2zO0PUOLBf0HldJfnA</recordid><startdate>20180730</startdate><enddate>20180730</enddate><creator>Gheorghe, Gheorghe I</creator><creator>Donțu, Octavian</creator><creator>Băran, Nicolae</creator><creator>Moga, Corina</creator><creator>Constantin, Mihaela</creator><creator>Tămășanu, Eugen</creator><general>Editura Cefin</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20180730</creationdate><title>RESEARCHES ON THE MEASUREMENT OF THE DISSOLVED OXYGEN CONCENTRATION IN STATIONARY WATERS</title><author>Gheorghe, Gheorghe I ; Donțu, Octavian ; Băran, Nicolae ; Moga, Corina ; Constantin, Mihaela ; Tămășanu, Eugen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1136-94472ced6d705d6d2dfdb0c3cc225384e195706ddcbbf566f7730718e03590693</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Air bubbles</topic><topic>Electrodes</topic><topic>Electrolytes</topic><topic>Engineering</topic><topic>Erosion mechanisms</topic><topic>Generators</topic><topic>Laboratories</topic><topic>Measurement methods</topic><topic>Methods</topic><topic>Microprocessors</topic><topic>Orifices</topic><topic>Oxygen</topic><topic>Water quality</topic><topic>Water temperature</topic><toplevel>online_resources</toplevel><creatorcontrib>Gheorghe, Gheorghe I</creatorcontrib><creatorcontrib>Donțu, Octavian</creatorcontrib><creatorcontrib>Băran, Nicolae</creatorcontrib><creatorcontrib>Moga, Corina</creatorcontrib><creatorcontrib>Constantin, Mihaela</creatorcontrib><creatorcontrib>Tămășanu, Eugen</creatorcontrib><collection>CrossRef</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>ProQuest advanced technologies & aerospace journals</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>International Journal of Mechatronics & Applied Mechanics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gheorghe, Gheorghe I</au><au>Donțu, Octavian</au><au>Băran, Nicolae</au><au>Moga, Corina</au><au>Constantin, Mihaela</au><au>Tămășanu, Eugen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>RESEARCHES ON THE MEASUREMENT OF THE DISSOLVED OXYGEN CONCENTRATION IN STATIONARY WATERS</atitle><jtitle>International Journal of Mechatronics & Applied Mechanics</jtitle><date>2018-07-30</date><risdate>2018</risdate><volume>1</volume><issue>3</issue><spage>120</spage><epage>126</epage><pages>120-126</pages><issn>2559-4397</issn><eissn>2559-6497</eissn><abstract>The paper presents methods for measuring the dissolved oxygen concentration in water; the electrical method is presented by presenting an experimental installation designed and built in the laboratories of POLITEHNICA University in Bucharest. For the creation of fine air bubbles, a bubble generator with 0.1 mm orifices processed by spark-erosion was used. The results of the experimental researches on the measurement of dissolved oxygen in water are presented.</abstract><cop>Bucharest</cop><pub>Editura Cefin</pub><doi>10.17683/ijomam/issue3.16</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2559-4397 |
ispartof | International Journal of Mechatronics & Applied Mechanics, 2018-07, Vol.1 (3), p.120-126 |
issn | 2559-4397 2559-6497 |
language | eng |
recordid | cdi_proquest_journals_2305779794 |
source | Publicly Available Content Database |
subjects | Air bubbles Electrodes Electrolytes Engineering Erosion mechanisms Generators Laboratories Measurement methods Methods Microprocessors Orifices Oxygen Water quality Water temperature |
title | RESEARCHES ON THE MEASUREMENT OF THE DISSOLVED OXYGEN CONCENTRATION IN STATIONARY WATERS |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-23T22%3A37%3A54IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=RESEARCHES%20ON%20THE%20MEASUREMENT%20OF%20THE%20DISSOLVED%20OXYGEN%20CONCENTRATION%20IN%20STATIONARY%20WATERS&rft.jtitle=International%20Journal%20of%20Mechatronics%20&%20Applied%20Mechanics&rft.au=Gheorghe,%20Gheorghe%20I&rft.date=2018-07-30&rft.volume=1&rft.issue=3&rft.spage=120&rft.epage=126&rft.pages=120-126&rft.issn=2559-4397&rft.eissn=2559-6497&rft_id=info:doi/10.17683/ijomam/issue3.16&rft_dat=%3Cproquest_cross%3E2305779794%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1136-94472ced6d705d6d2dfdb0c3cc225384e195706ddcbbf566f7730718e03590693%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2305779794&rft_id=info:pmid/&rfr_iscdi=true |