Loading…

Simultaneous Determination of Various Phosphates in Water-Soluble Ammonium Polyphosphate

Based on ion chromatography, this study developed a rapid method for simultaneous determination of linear polyphosphates (PPs) of orthophosphate (P 1 ), pyrophosphate (P 2 ), trimetaphosphate (P 3m ), tripolyphosphate (P 3 ), tetraphosphate (P 4 ), pentaphosphate (P 5 ), and hexaphosphate (P 6 ) in...

Full description

Saved in:
Bibliographic Details
Published in:Chromatographia 2019-11, Vol.82 (11), p.1687-1695
Main Authors: Xie, Wen-Ji, Wang, Xin-Long, Li, Yong-Sheng, Xu, De-Hua, Zhong, Yan-Jun, Yang, Jing-Xu
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Based on ion chromatography, this study developed a rapid method for simultaneous determination of linear polyphosphates (PPs) of orthophosphate (P 1 ), pyrophosphate (P 2 ), trimetaphosphate (P 3m ), tripolyphosphate (P 3 ), tetraphosphate (P 4 ), pentaphosphate (P 5 ), and hexaphosphate (P 6 ) in water-soluble ammonium polyphosphate (WAPP). Investigation indicated that the retention of PPs in column was endothermic and cooling column benefited the elution of PPs. With adjusting the elution mode, eluent (KOH) concentration, gradient time, flowrate, and column temperature, the optimized results were as follows: the injection volume of sample was 1.3 μL, column temperature was 30 °C, and flowrate of the eluent was 1.2 ml min −1 . The linear equations for six phosphates are: y  = 0.011 c P1  + 0.021 ( r  = 0.9998), y  = 0.012 c P2  + 0.023, y  = 0.011 c P3m  − 0.013 ( r  = 0.9997), y  = 0.12 c P3  + 0.017 ( r  = 0.9999), y  = 0.011 c P4  + 0.004 ( r  = 0.9983), y  = 0.011 c P5  − 0.082 ( r  = 0.9962), and y  = 0.013 c P6  − 0.029 ( r  = 0.9989), respectively. The determination ranges are: 1–500 mg L −1 for P 1 , P 2 , P 3m , and P 3 ; and 1–100 mg L −1 for P 4 , P 5 , and P 6 . The recovery is in the range 95–104% for P 1 , P 2 , P 3m , P 3 , P 4 , P 5 , and P 6 ; the detection limit is in the range 0.17–0.54 mg L −1 and RSDs of intra- and inter-day determination are 0.56–2.51% ( n  = 5) for seven PPs, and the analysis period is 15 min. The method was consistent with both gravimetric method and molybdenum blue method, while the RSD was in the range 0.61–1.87%. This rapid method can be applied in the determination of total phosphorus and various phosphates in PPs.
ISSN:0009-5893
1612-1112
DOI:10.1007/s10337-019-03786-x