Loading…
A study of X-ray, gamma and neutron shielding parameters in Si- alloys
We have studied the X-ray and gamma radiation shielding parameters such as mass attenuation coefficient, linear attenuation coefficient, half value layer, tenth value layer, effective atomic numbers, exposure buildup factors and specific gamma ray constant in aluminum silicon alloys (Al-47, Al– 32S,...
Saved in:
Published in: | Radiation physics and chemistry (Oxford, England : 1993) England : 1993), 2019-12, Vol.165, p.108414, Article 108414 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c349t-c4066b5c3a0cb01472bdbc942997ad1d680771bcab9c6a45965c03078b558f953 |
---|---|
cites | cdi_FETCH-LOGICAL-c349t-c4066b5c3a0cb01472bdbc942997ad1d680771bcab9c6a45965c03078b558f953 |
container_end_page | |
container_issue | |
container_start_page | 108414 |
container_title | Radiation physics and chemistry (Oxford, England : 1993) |
container_volume | 165 |
creator | Manjunatha, H.C. Sathish, K.V. Seenappa, L. Gupta, Damodara Cecil Raj, S. Alfred |
description | We have studied the X-ray and gamma radiation shielding parameters such as mass attenuation coefficient, linear attenuation coefficient, half value layer, tenth value layer, effective atomic numbers, exposure buildup factors and specific gamma ray constant in aluminum silicon alloys (Al-47, Al– 32S, Al-43, Fe–Si, Al-356, Al-355 and Al-A355). We have also studied the neutron shielding properties such as coherent neutron scattering length, incoherent neutron scattering lengths, coherent neutron scattering cross section, incoherent neutron scattering cross sections, total neutron scattering cross section and neutron absorption cross sections in aluminium silicon alloys. It has been compared the shielding properties among the studied aluminium silicon alloys. From the detail study it is found that mean free path, HVL and TVL is minimum and exposure buildup factor is maximum for ferro-silicon alloy. Hence it is clear that ferro-silicon alloy is good absorber for X-ray and gamma radiation. The attenuation parameters for neutron are large for ferro silicon alloy. Hence, we suggest ferro silicon alloy is the best shielding materials for X-ray, gamma and neutrons.
•We have studied the X-ray and gamma radiation shielding parameters in silicon alloys.•We have also studied the neutron shielding properties.•It has been compared the shielding properties among the studied aluminium silicon alloys.•The attenuation parameters for neutron are large for ferro silicon alloy.•We suggest ferro silicon alloy is the best shielding materials for X-ray, gamma and neutrons. |
doi_str_mv | 10.1016/j.radphyschem.2019.108414 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2308019370</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0969806X19303081</els_id><sourcerecordid>2308019370</sourcerecordid><originalsourceid>FETCH-LOGICAL-c349t-c4066b5c3a0cb01472bdbc942997ad1d680771bcab9c6a45965c03078b558f953</originalsourceid><addsrcrecordid>eNqNkE9LxDAQxYMouK5-h4hXu07aJk2Oy-KuwoIHFfYW0iTdTek_k1bot7dLPXj0NDC892beD6F7AisChD2VK69MdxqDPtl6FQMR056nJL1AC8IzEQEX9BItQDARcWCHa3QTQgkAGafJAm3XOPSDGXFb4EPk1fiIj6quFVaNwY0det82OJycrYxrjrhTXtW2tz5g1-B3F2FVVe0YbtFVoapg737nEn1unz82L9H-bfe6We8jnaSij3QKjOVUJwp0DiTN4tzkWqSxEJkyxDAOWUZyrXKhmUqpYFRDMr2aU8oLQZMlephzO99-DTb0smwH30wnZZwAn-onGUwqMau0b0PwtpCdd7XyoyQgz9hkKf9gk2dscsY2eTez1041vp31MmhnG22N81b30rTuHyk_o1l6ww</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2308019370</pqid></control><display><type>article</type><title>A study of X-ray, gamma and neutron shielding parameters in Si- alloys</title><source>Elsevier</source><creator>Manjunatha, H.C. ; Sathish, K.V. ; Seenappa, L. ; Gupta, Damodara ; Cecil Raj, S. Alfred</creator><creatorcontrib>Manjunatha, H.C. ; Sathish, K.V. ; Seenappa, L. ; Gupta, Damodara ; Cecil Raj, S. Alfred</creatorcontrib><description>We have studied the X-ray and gamma radiation shielding parameters such as mass attenuation coefficient, linear attenuation coefficient, half value layer, tenth value layer, effective atomic numbers, exposure buildup factors and specific gamma ray constant in aluminum silicon alloys (Al-47, Al– 32S, Al-43, Fe–Si, Al-356, Al-355 and Al-A355). We have also studied the neutron shielding properties such as coherent neutron scattering length, incoherent neutron scattering lengths, coherent neutron scattering cross section, incoherent neutron scattering cross sections, total neutron scattering cross section and neutron absorption cross sections in aluminium silicon alloys. It has been compared the shielding properties among the studied aluminium silicon alloys. From the detail study it is found that mean free path, HVL and TVL is minimum and exposure buildup factor is maximum for ferro-silicon alloy. Hence it is clear that ferro-silicon alloy is good absorber for X-ray and gamma radiation. The attenuation parameters for neutron are large for ferro silicon alloy. Hence, we suggest ferro silicon alloy is the best shielding materials for X-ray, gamma and neutrons.
•We have studied the X-ray and gamma radiation shielding parameters in silicon alloys.•We have also studied the neutron shielding properties.•It has been compared the shielding properties among the studied aluminium silicon alloys.•The attenuation parameters for neutron are large for ferro silicon alloy.•We suggest ferro silicon alloy is the best shielding materials for X-ray, gamma and neutrons.</description><identifier>ISSN: 0969-806X</identifier><identifier>EISSN: 1879-0895</identifier><identifier>DOI: 10.1016/j.radphyschem.2019.108414</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Absorption cross sections ; Alloys ; Aluminum base alloys ; Attenuation coefficients ; Coherent scattering ; Gamma ; Gamma rays ; Iron ; Neutron ; Neutron absorption ; Neutron scattering ; Neutrons ; Parameters ; Radiation shielding ; Scattering cross sections ; Shielding ; Silicon ; X-ray</subject><ispartof>Radiation physics and chemistry (Oxford, England : 1993), 2019-12, Vol.165, p.108414, Article 108414</ispartof><rights>2019 Elsevier Ltd</rights><rights>Copyright Elsevier BV Dec 2019</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c349t-c4066b5c3a0cb01472bdbc942997ad1d680771bcab9c6a45965c03078b558f953</citedby><cites>FETCH-LOGICAL-c349t-c4066b5c3a0cb01472bdbc942997ad1d680771bcab9c6a45965c03078b558f953</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail></links><search><creatorcontrib>Manjunatha, H.C.</creatorcontrib><creatorcontrib>Sathish, K.V.</creatorcontrib><creatorcontrib>Seenappa, L.</creatorcontrib><creatorcontrib>Gupta, Damodara</creatorcontrib><creatorcontrib>Cecil Raj, S. Alfred</creatorcontrib><title>A study of X-ray, gamma and neutron shielding parameters in Si- alloys</title><title>Radiation physics and chemistry (Oxford, England : 1993)</title><description>We have studied the X-ray and gamma radiation shielding parameters such as mass attenuation coefficient, linear attenuation coefficient, half value layer, tenth value layer, effective atomic numbers, exposure buildup factors and specific gamma ray constant in aluminum silicon alloys (Al-47, Al– 32S, Al-43, Fe–Si, Al-356, Al-355 and Al-A355). We have also studied the neutron shielding properties such as coherent neutron scattering length, incoherent neutron scattering lengths, coherent neutron scattering cross section, incoherent neutron scattering cross sections, total neutron scattering cross section and neutron absorption cross sections in aluminium silicon alloys. It has been compared the shielding properties among the studied aluminium silicon alloys. From the detail study it is found that mean free path, HVL and TVL is minimum and exposure buildup factor is maximum for ferro-silicon alloy. Hence it is clear that ferro-silicon alloy is good absorber for X-ray and gamma radiation. The attenuation parameters for neutron are large for ferro silicon alloy. Hence, we suggest ferro silicon alloy is the best shielding materials for X-ray, gamma and neutrons.
•We have studied the X-ray and gamma radiation shielding parameters in silicon alloys.•We have also studied the neutron shielding properties.•It has been compared the shielding properties among the studied aluminium silicon alloys.•The attenuation parameters for neutron are large for ferro silicon alloy.•We suggest ferro silicon alloy is the best shielding materials for X-ray, gamma and neutrons.</description><subject>Absorption cross sections</subject><subject>Alloys</subject><subject>Aluminum base alloys</subject><subject>Attenuation coefficients</subject><subject>Coherent scattering</subject><subject>Gamma</subject><subject>Gamma rays</subject><subject>Iron</subject><subject>Neutron</subject><subject>Neutron absorption</subject><subject>Neutron scattering</subject><subject>Neutrons</subject><subject>Parameters</subject><subject>Radiation shielding</subject><subject>Scattering cross sections</subject><subject>Shielding</subject><subject>Silicon</subject><subject>X-ray</subject><issn>0969-806X</issn><issn>1879-0895</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqNkE9LxDAQxYMouK5-h4hXu07aJk2Oy-KuwoIHFfYW0iTdTek_k1bot7dLPXj0NDC892beD6F7AisChD2VK69MdxqDPtl6FQMR056nJL1AC8IzEQEX9BItQDARcWCHa3QTQgkAGafJAm3XOPSDGXFb4EPk1fiIj6quFVaNwY0det82OJycrYxrjrhTXtW2tz5g1-B3F2FVVe0YbtFVoapg737nEn1unz82L9H-bfe6We8jnaSij3QKjOVUJwp0DiTN4tzkWqSxEJkyxDAOWUZyrXKhmUqpYFRDMr2aU8oLQZMlephzO99-DTb0smwH30wnZZwAn-onGUwqMau0b0PwtpCdd7XyoyQgz9hkKf9gk2dscsY2eTez1041vp31MmhnG22N81b30rTuHyk_o1l6ww</recordid><startdate>201912</startdate><enddate>201912</enddate><creator>Manjunatha, H.C.</creator><creator>Sathish, K.V.</creator><creator>Seenappa, L.</creator><creator>Gupta, Damodara</creator><creator>Cecil Raj, S. Alfred</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>201912</creationdate><title>A study of X-ray, gamma and neutron shielding parameters in Si- alloys</title><author>Manjunatha, H.C. ; Sathish, K.V. ; Seenappa, L. ; Gupta, Damodara ; Cecil Raj, S. Alfred</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c349t-c4066b5c3a0cb01472bdbc942997ad1d680771bcab9c6a45965c03078b558f953</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Absorption cross sections</topic><topic>Alloys</topic><topic>Aluminum base alloys</topic><topic>Attenuation coefficients</topic><topic>Coherent scattering</topic><topic>Gamma</topic><topic>Gamma rays</topic><topic>Iron</topic><topic>Neutron</topic><topic>Neutron absorption</topic><topic>Neutron scattering</topic><topic>Neutrons</topic><topic>Parameters</topic><topic>Radiation shielding</topic><topic>Scattering cross sections</topic><topic>Shielding</topic><topic>Silicon</topic><topic>X-ray</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Manjunatha, H.C.</creatorcontrib><creatorcontrib>Sathish, K.V.</creatorcontrib><creatorcontrib>Seenappa, L.</creatorcontrib><creatorcontrib>Gupta, Damodara</creatorcontrib><creatorcontrib>Cecil Raj, S. Alfred</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Radiation physics and chemistry (Oxford, England : 1993)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Manjunatha, H.C.</au><au>Sathish, K.V.</au><au>Seenappa, L.</au><au>Gupta, Damodara</au><au>Cecil Raj, S. Alfred</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A study of X-ray, gamma and neutron shielding parameters in Si- alloys</atitle><jtitle>Radiation physics and chemistry (Oxford, England : 1993)</jtitle><date>2019-12</date><risdate>2019</risdate><volume>165</volume><spage>108414</spage><pages>108414-</pages><artnum>108414</artnum><issn>0969-806X</issn><eissn>1879-0895</eissn><abstract>We have studied the X-ray and gamma radiation shielding parameters such as mass attenuation coefficient, linear attenuation coefficient, half value layer, tenth value layer, effective atomic numbers, exposure buildup factors and specific gamma ray constant in aluminum silicon alloys (Al-47, Al– 32S, Al-43, Fe–Si, Al-356, Al-355 and Al-A355). We have also studied the neutron shielding properties such as coherent neutron scattering length, incoherent neutron scattering lengths, coherent neutron scattering cross section, incoherent neutron scattering cross sections, total neutron scattering cross section and neutron absorption cross sections in aluminium silicon alloys. It has been compared the shielding properties among the studied aluminium silicon alloys. From the detail study it is found that mean free path, HVL and TVL is minimum and exposure buildup factor is maximum for ferro-silicon alloy. Hence it is clear that ferro-silicon alloy is good absorber for X-ray and gamma radiation. The attenuation parameters for neutron are large for ferro silicon alloy. Hence, we suggest ferro silicon alloy is the best shielding materials for X-ray, gamma and neutrons.
•We have studied the X-ray and gamma radiation shielding parameters in silicon alloys.•We have also studied the neutron shielding properties.•It has been compared the shielding properties among the studied aluminium silicon alloys.•The attenuation parameters for neutron are large for ferro silicon alloy.•We suggest ferro silicon alloy is the best shielding materials for X-ray, gamma and neutrons.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.radphyschem.2019.108414</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0969-806X |
ispartof | Radiation physics and chemistry (Oxford, England : 1993), 2019-12, Vol.165, p.108414, Article 108414 |
issn | 0969-806X 1879-0895 |
language | eng |
recordid | cdi_proquest_journals_2308019370 |
source | Elsevier |
subjects | Absorption cross sections Alloys Aluminum base alloys Attenuation coefficients Coherent scattering Gamma Gamma rays Iron Neutron Neutron absorption Neutron scattering Neutrons Parameters Radiation shielding Scattering cross sections Shielding Silicon X-ray |
title | A study of X-ray, gamma and neutron shielding parameters in Si- alloys |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-03-09T12%3A31%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20study%20of%20X-ray,%20gamma%20and%20neutron%20shielding%20parameters%20in%20Si-%20alloys&rft.jtitle=Radiation%20physics%20and%20chemistry%20(Oxford,%20England%20:%201993)&rft.au=Manjunatha,%20H.C.&rft.date=2019-12&rft.volume=165&rft.spage=108414&rft.pages=108414-&rft.artnum=108414&rft.issn=0969-806X&rft.eissn=1879-0895&rft_id=info:doi/10.1016/j.radphyschem.2019.108414&rft_dat=%3Cproquest_cross%3E2308019370%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c349t-c4066b5c3a0cb01472bdbc942997ad1d680771bcab9c6a45965c03078b558f953%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2308019370&rft_id=info:pmid/&rfr_iscdi=true |