Loading…
Effects of silica nanoparticles and low concentration on the deterioration of critical heat flux in a pool boiling experiment with a flat-type heater
•CHF experiments were conducted depending on particle size and concentration.•CHF decreased at low concentrations, and increased at high concentrations.•Higher CHF values were observed with smaller size of nanoparticles.•Submicron-sized particles had different CHF trends from nano-sized particles. A...
Saved in:
Published in: | International journal of heat and mass transfer 2019-12, Vol.144, p.118420, Article 118420 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | •CHF experiments were conducted depending on particle size and concentration.•CHF decreased at low concentrations, and increased at high concentrations.•Higher CHF values were observed with smaller size of nanoparticles.•Submicron-sized particles had different CHF trends from nano-sized particles.
An evaluation of nanoparticle size effects on the critical heat flux (CHF) was conducted through pool boiling experiments under atmospheric pressure in low concentration regions from 0.1 to 10 ppmv. A smooth flat-type heater made of stainless steel was used as a test section. Silica nanofluids were prepared by sonication processes to guarantee stability using various sizes of silica nanoparticles (8, 15, 65, and 400 nm). In the experiments, we observed the CHF enhancement at high concentration regardless of particle size. However, the deterioration of the CHF was observed in the relatively low concentration regions with particles that were smaller than 100 nm. Furthermore, when the particle size decreased, the CHF values appeared to be higher at the high concentration of 10 ppmv. On the other hand, for large particles with a size of 400 nm, no deterioration of the CHF at low concentrations was observed. The boiling time, which is considered to affect the nanoparticle deposition, had marginal influences on CHF values. Based on the CHF trends, surface analyses with heaters after the experiments were conducted through SEM images, and contact angles and roughness values were used to evaluate the surface characteristics modified by nanoparticle deposition. Furthermore, in this study, the discussions on the particle size effects and deterioration of the CHF, and also its enhancement, are included based on the behavior of the structural disjoining pressure, nucleation site density, and porous layer as a function of the nanoparticle size and concentration. |
---|---|
ISSN: | 0017-9310 1879-2189 |
DOI: | 10.1016/j.ijheatmasstransfer.2019.07.070 |