Development of ultrahigh resolution radiation imaging detector using 1 mm channel size Si-PM array combined with 0.2 mm × 0.2 mm pixelated GAGG plate

For precise distribution measurements of gamma photons or beta particles, high resolution radiation imaging detectors are required. Reducing the size of the photodetectors combined with small pixel scintillators is a possible method to improve the spatial resolution of the scintillator based radiati...

Full description

Saved in:
Bibliographic Details
Published in:Journal of instrumentation 2018-05, Vol.13 (5), p.P05028-P05028
Main Authors: Yamamoto, S., Kataoka, J., Fukuchi, T., Kamada, K., Yoshikawa, A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c198t-7cf49a8a7661d751d24320d697b0345935392e8bdbe7f36aaa53b1f8a35644e43
cites cdi_FETCH-LOGICAL-c198t-7cf49a8a7661d751d24320d697b0345935392e8bdbe7f36aaa53b1f8a35644e43
container_end_page P05028
container_issue 5
container_start_page P05028
container_title Journal of instrumentation
container_volume 13
creator Yamamoto, S.
Kataoka, J.
Fukuchi, T.
Kamada, K.
Yoshikawa, A.
description For precise distribution measurements of gamma photons or beta particles, high resolution radiation imaging detectors are required. Reducing the size of the photodetectors combined with small pixel scintillators is a possible method to improve the spatial resolution of the scintillator based radiation imaging detectors. In this paper, we used a 1mm channel size silicon photomultiplier (Si-PM) array combined with a small pixel scintillator array and evaluated the performance for gamma photons and beta particles. For the radiation imaging detector, a Si-PM array with 1mm × 1mm channel size arranged in 8 × 8 (Hamamatsu, S13615-1025N-08) was optically coupled to a 0.2 mm × 0.2 mm pixelated GAGG plate. For 662 keV high energy gamma photons, 0.2mm GAGG pixels were clearly resolved in the position histogram. The peak to valley ratio (P/V) of the position histogram was not improved when only photo-peak events were used while it was improved when the events lower energy than the Compton edge was used. We could also resolve the position histograms for both 122 keV and 60 keV gamma photons. For beta particles, although the position histogram showed good separation for relatively low energy beta particles of Ca-45 (245 keV max), separation became worse for higher energy beta particles from Sr-Y-90 (545keV and 2280keV max). The separation of the position histogram for Sr-Y-90 improved when only lower energy events were used. Using 1mm size Si-PM array, high resolution detectors was realized for low energy gamma photons and beta particle but the spatial resolution was decreased for high energy beta particles from Sr-Y-90.
doi_str_mv 10.1088/1748-0221/13/05/P05028
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2365693118</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2365693118</sourcerecordid><originalsourceid>FETCH-LOGICAL-c198t-7cf49a8a7661d751d24320d697b0345935392e8bdbe7f36aaa53b1f8a35644e43</originalsourceid><addsrcrecordid>eNpNkd9KwzAUxosoOKevIAGva5PmT9PLMbUKEwfqdUjbdMtom5qk6nwQfSBfzNapeHV-h-_jHPi-IDhF8BxBziOUEB7COEYRwhGk0RJSGPO9YPIn7P_jw-DIuQ2ENKUEToL3C_WsatM1qvXAVKCvvZVrvVoDq5ype69NC6wstfwm3ciVblegVF4V3ljQu3FFoGlAsZZtq2rg9JsC9zpc3gJprdyCwjS5blUJXrRfA3gej-7Pj1_q9KuqpR_0bJZloBv5ODioZO3Uyc-cBo9Xlw_z63Bxl93MZ4uwQCn3YVJUJJVcJoyhMqGojAmOYcnSJIeY0BRTnMaK52WukgozKSXFOaq4xJQRogieBme7u501T71yXmxMb9vhpYgxoyzFCPHBxXauwhrnrKpEZ4ck7FYgKMYOxBivGOMVCAtIxa4D_AUERXoe</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2365693118</pqid></control><display><type>article</type><title>Development of ultrahigh resolution radiation imaging detector using 1 mm channel size Si-PM array combined with 0.2 mm × 0.2 mm pixelated GAGG plate</title><source>Institute of Physics</source><creator>Yamamoto, S. ; Kataoka, J. ; Fukuchi, T. ; Kamada, K. ; Yoshikawa, A.</creator><creatorcontrib>Yamamoto, S. ; Kataoka, J. ; Fukuchi, T. ; Kamada, K. ; Yoshikawa, A.</creatorcontrib><description>For precise distribution measurements of gamma photons or beta particles, high resolution radiation imaging detectors are required. Reducing the size of the photodetectors combined with small pixel scintillators is a possible method to improve the spatial resolution of the scintillator based radiation imaging detectors. In this paper, we used a 1mm channel size silicon photomultiplier (Si-PM) array combined with a small pixel scintillator array and evaluated the performance for gamma photons and beta particles. For the radiation imaging detector, a Si-PM array with 1mm × 1mm channel size arranged in 8 × 8 (Hamamatsu, S13615-1025N-08) was optically coupled to a 0.2 mm × 0.2 mm pixelated GAGG plate. For 662 keV high energy gamma photons, 0.2mm GAGG pixels were clearly resolved in the position histogram. The peak to valley ratio (P/V) of the position histogram was not improved when only photo-peak events were used while it was improved when the events lower energy than the Compton edge was used. We could also resolve the position histograms for both 122 keV and 60 keV gamma photons. For beta particles, although the position histogram showed good separation for relatively low energy beta particles of Ca-45 (245 keV max), separation became worse for higher energy beta particles from Sr-Y-90 (545keV and 2280keV max). The separation of the position histogram for Sr-Y-90 improved when only lower energy events were used. Using 1mm size Si-PM array, high resolution detectors was realized for low energy gamma photons and beta particle but the spatial resolution was decreased for high energy beta particles from Sr-Y-90.</description><identifier>ISSN: 1748-0221</identifier><identifier>EISSN: 1748-0221</identifier><identifier>DOI: 10.1088/1748-0221/13/05/P05028</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Arrays ; Atoms &amp; subatomic particles ; Beta particles ; Beta rays ; Energy ; High resolution ; Histograms ; Image resolution ; Photomultiplier tubes ; Photons ; Pixels ; Scintillation counters ; Sensors ; Separation ; Silicon ; Spatial resolution ; Strontium</subject><ispartof>Journal of instrumentation, 2018-05, Vol.13 (5), p.P05028-P05028</ispartof><rights>Copyright IOP Publishing May 2018</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c198t-7cf49a8a7661d751d24320d697b0345935392e8bdbe7f36aaa53b1f8a35644e43</citedby><cites>FETCH-LOGICAL-c198t-7cf49a8a7661d751d24320d697b0345935392e8bdbe7f36aaa53b1f8a35644e43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Yamamoto, S.</creatorcontrib><creatorcontrib>Kataoka, J.</creatorcontrib><creatorcontrib>Fukuchi, T.</creatorcontrib><creatorcontrib>Kamada, K.</creatorcontrib><creatorcontrib>Yoshikawa, A.</creatorcontrib><title>Development of ultrahigh resolution radiation imaging detector using 1 mm channel size Si-PM array combined with 0.2 mm × 0.2 mm pixelated GAGG plate</title><title>Journal of instrumentation</title><description>For precise distribution measurements of gamma photons or beta particles, high resolution radiation imaging detectors are required. Reducing the size of the photodetectors combined with small pixel scintillators is a possible method to improve the spatial resolution of the scintillator based radiation imaging detectors. In this paper, we used a 1mm channel size silicon photomultiplier (Si-PM) array combined with a small pixel scintillator array and evaluated the performance for gamma photons and beta particles. For the radiation imaging detector, a Si-PM array with 1mm × 1mm channel size arranged in 8 × 8 (Hamamatsu, S13615-1025N-08) was optically coupled to a 0.2 mm × 0.2 mm pixelated GAGG plate. For 662 keV high energy gamma photons, 0.2mm GAGG pixels were clearly resolved in the position histogram. The peak to valley ratio (P/V) of the position histogram was not improved when only photo-peak events were used while it was improved when the events lower energy than the Compton edge was used. We could also resolve the position histograms for both 122 keV and 60 keV gamma photons. For beta particles, although the position histogram showed good separation for relatively low energy beta particles of Ca-45 (245 keV max), separation became worse for higher energy beta particles from Sr-Y-90 (545keV and 2280keV max). The separation of the position histogram for Sr-Y-90 improved when only lower energy events were used. Using 1mm size Si-PM array, high resolution detectors was realized for low energy gamma photons and beta particle but the spatial resolution was decreased for high energy beta particles from Sr-Y-90.</description><subject>Arrays</subject><subject>Atoms &amp; subatomic particles</subject><subject>Beta particles</subject><subject>Beta rays</subject><subject>Energy</subject><subject>High resolution</subject><subject>Histograms</subject><subject>Image resolution</subject><subject>Photomultiplier tubes</subject><subject>Photons</subject><subject>Pixels</subject><subject>Scintillation counters</subject><subject>Sensors</subject><subject>Separation</subject><subject>Silicon</subject><subject>Spatial resolution</subject><subject>Strontium</subject><issn>1748-0221</issn><issn>1748-0221</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNpNkd9KwzAUxosoOKevIAGva5PmT9PLMbUKEwfqdUjbdMtom5qk6nwQfSBfzNapeHV-h-_jHPi-IDhF8BxBziOUEB7COEYRwhGk0RJSGPO9YPIn7P_jw-DIuQ2ENKUEToL3C_WsatM1qvXAVKCvvZVrvVoDq5ype69NC6wstfwm3ciVblegVF4V3ljQu3FFoGlAsZZtq2rg9JsC9zpc3gJprdyCwjS5blUJXrRfA3gej-7Pj1_q9KuqpR_0bJZloBv5ODioZO3Uyc-cBo9Xlw_z63Bxl93MZ4uwQCn3YVJUJJVcJoyhMqGojAmOYcnSJIeY0BRTnMaK52WukgozKSXFOaq4xJQRogieBme7u501T71yXmxMb9vhpYgxoyzFCPHBxXauwhrnrKpEZ4ck7FYgKMYOxBivGOMVCAtIxa4D_AUERXoe</recordid><startdate>20180529</startdate><enddate>20180529</enddate><creator>Yamamoto, S.</creator><creator>Kataoka, J.</creator><creator>Fukuchi, T.</creator><creator>Kamada, K.</creator><creator>Yoshikawa, A.</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20180529</creationdate><title>Development of ultrahigh resolution radiation imaging detector using 1 mm channel size Si-PM array combined with 0.2 mm × 0.2 mm pixelated GAGG plate</title><author>Yamamoto, S. ; Kataoka, J. ; Fukuchi, T. ; Kamada, K. ; Yoshikawa, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c198t-7cf49a8a7661d751d24320d697b0345935392e8bdbe7f36aaa53b1f8a35644e43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Arrays</topic><topic>Atoms &amp; subatomic particles</topic><topic>Beta particles</topic><topic>Beta rays</topic><topic>Energy</topic><topic>High resolution</topic><topic>Histograms</topic><topic>Image resolution</topic><topic>Photomultiplier tubes</topic><topic>Photons</topic><topic>Pixels</topic><topic>Scintillation counters</topic><topic>Sensors</topic><topic>Separation</topic><topic>Silicon</topic><topic>Spatial resolution</topic><topic>Strontium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yamamoto, S.</creatorcontrib><creatorcontrib>Kataoka, J.</creatorcontrib><creatorcontrib>Fukuchi, T.</creatorcontrib><creatorcontrib>Kamada, K.</creatorcontrib><creatorcontrib>Yoshikawa, A.</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Journal of instrumentation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yamamoto, S.</au><au>Kataoka, J.</au><au>Fukuchi, T.</au><au>Kamada, K.</au><au>Yoshikawa, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of ultrahigh resolution radiation imaging detector using 1 mm channel size Si-PM array combined with 0.2 mm × 0.2 mm pixelated GAGG plate</atitle><jtitle>Journal of instrumentation</jtitle><date>2018-05-29</date><risdate>2018</risdate><volume>13</volume><issue>5</issue><spage>P05028</spage><epage>P05028</epage><pages>P05028-P05028</pages><issn>1748-0221</issn><eissn>1748-0221</eissn><abstract>For precise distribution measurements of gamma photons or beta particles, high resolution radiation imaging detectors are required. Reducing the size of the photodetectors combined with small pixel scintillators is a possible method to improve the spatial resolution of the scintillator based radiation imaging detectors. In this paper, we used a 1mm channel size silicon photomultiplier (Si-PM) array combined with a small pixel scintillator array and evaluated the performance for gamma photons and beta particles. For the radiation imaging detector, a Si-PM array with 1mm × 1mm channel size arranged in 8 × 8 (Hamamatsu, S13615-1025N-08) was optically coupled to a 0.2 mm × 0.2 mm pixelated GAGG plate. For 662 keV high energy gamma photons, 0.2mm GAGG pixels were clearly resolved in the position histogram. The peak to valley ratio (P/V) of the position histogram was not improved when only photo-peak events were used while it was improved when the events lower energy than the Compton edge was used. We could also resolve the position histograms for both 122 keV and 60 keV gamma photons. For beta particles, although the position histogram showed good separation for relatively low energy beta particles of Ca-45 (245 keV max), separation became worse for higher energy beta particles from Sr-Y-90 (545keV and 2280keV max). The separation of the position histogram for Sr-Y-90 improved when only lower energy events were used. Using 1mm size Si-PM array, high resolution detectors was realized for low energy gamma photons and beta particle but the spatial resolution was decreased for high energy beta particles from Sr-Y-90.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1748-0221/13/05/P05028</doi></addata></record>
fulltext fulltext
identifier ISSN: 1748-0221
ispartof Journal of instrumentation, 2018-05, Vol.13 (5), p.P05028-P05028
issn 1748-0221
1748-0221
language eng
recordid cdi_proquest_journals_2365693118
source Institute of Physics
subjects Arrays
Atoms & subatomic particles
Beta particles
Beta rays
Energy
High resolution
Histograms
Image resolution
Photomultiplier tubes
Photons
Pixels
Scintillation counters
Sensors
Separation
Silicon
Spatial resolution
Strontium
title Development of ultrahigh resolution radiation imaging detector using 1 mm channel size Si-PM array combined with 0.2 mm × 0.2 mm pixelated GAGG plate
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T22%3A05%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20ultrahigh%20resolution%20radiation%20imaging%20detector%20using%201%20mm%20channel%20size%20Si-PM%20array%20combined%20with%200.2%20mm%20%C3%97%200.2%20mm%20pixelated%20GAGG%20plate&rft.jtitle=Journal%20of%20instrumentation&rft.au=Yamamoto,%20S.&rft.date=2018-05-29&rft.volume=13&rft.issue=5&rft.spage=P05028&rft.epage=P05028&rft.pages=P05028-P05028&rft.issn=1748-0221&rft.eissn=1748-0221&rft_id=info:doi/10.1088/1748-0221/13/05/P05028&rft_dat=%3Cproquest_cross%3E2365693118%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c198t-7cf49a8a7661d751d24320d697b0345935392e8bdbe7f36aaa53b1f8a35644e43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2365693118&rft_id=info:pmid/&rfr_iscdi=true