Loading…
Effect of the Charge Process and Discharge Rate on the Lithium Stripping Process Visibility in LiFePO4-Graphite Li-ion Cells during Charge-Discharge Cycling at 0°C
Commercially available 18650 LiFePO4-Graphite Li-ion cells were exposed to charge-discharge cycling at 0°C following two different charge methods: constant current-constant voltage (CC-CV) and constant current (CC), and two different discharge rates: 1 C and 0.2 C. The effect of the charge method an...
Saved in:
Published in: | Denki kagaku oyobi kōgyō butsuri kagaku 2020/07/05, Vol.88(4), pp.340-342 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Commercially available 18650 LiFePO4-Graphite Li-ion cells were exposed to charge-discharge cycling at 0°C following two different charge methods: constant current-constant voltage (CC-CV) and constant current (CC), and two different discharge rates: 1 C and 0.2 C. The effect of the charge method and discharge rate on the cell performance was analyzed. The cell exposed to CC charge and 1 C discharge-rate showed a high voltage plateau at the beginning of the discharge voltage, while a high voltage plateau was not observed in the discharge profiles of the cells exposed to a discharge rate of 0.2 C. |
---|---|
ISSN: | 1344-3542 2186-2451 |
DOI: | 10.5796/electrochemistry.20-00052 |