Comparison and assessment of electricity generation capacity for different types of PV solar plants of 1MW in Soko banja, Serbia

This paper gives the results of the electricity generated by the fixed, one-axis and dual-axis tracking PV solar plant of 1 MW with flat PV panels made of monocrystalline silicon which is to be built in the area of Soko banja (spa in Serbia). Further on follows a description of the functioning of th...

Full description

Saved in:
Bibliographic Details
Published in:Thermal science 2011, Vol.15 (3), p.605-618
Main Authors: Pavlovic, Tomislav, Milosavljevic, Dragana, Radivojevic, Aleksandar, Pavlovic, Mila
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c152p-864f17339156a1609e6685732a42961d0ab78f5a2f6a1de376d0509c9eca1f9a3
cites
container_end_page 618
container_issue 3
container_start_page 605
container_title Thermal science
container_volume 15
creator Pavlovic, Tomislav
Milosavljevic, Dragana
Radivojevic, Aleksandar
Pavlovic, Mila
description This paper gives the results of the electricity generated by the fixed, one-axis and dual-axis tracking PV solar plant of 1 MW with flat PV panels made of monocrystalline silicon which is to be built in the area of Soko banja (spa in Serbia). Further on follows a description of the functioning of the fixed and one-axis and dual-axis tracking PV solar plant. For the calculation of the electricity generated by these plants PVGIS program from the Internet was used. Calculations have shown that fixed PV solar plant power of 1 MW, solar modules of monocrystalline silicon yield 1130000 kWh power output, one-axis tracking PV solar plant yields 1420000 kWh, and dual-axis tracking PV solar plant yields 1450000 kWh of electricity. Electricity generated by the fixed PV solar plant could satisfy 86% of the annual needs for the electricity of the ?Zdravljak? hotel and the special ?Novi stacionar? hospital in Soko banja. nema
doi_str_mv 10.2298/TSCI110322065P
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2429869923</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2429869923</sourcerecordid><originalsourceid>FETCH-LOGICAL-c152p-864f17339156a1609e6685732a42961d0ab78f5a2f6a1de376d0509c9eca1f9a3</originalsourceid><addsrcrecordid>eNpVkL1PwzAQxS0EEqWwMltiJcUfiROPKOKjUhGVWmCMrskZuaR2sNOhG386acvCdNK7997pfoRcczYRQhd3y0U55ZxJIZjK5idkJKRMk5wreUpGTGZpogupzslFjGvGlCqKfER-Sr_pINjoHQXXUIgRY9yg66k3FFus-2Br2-_oJzoM0NvBWEMHB834QBtrDIZ9oN91GPex-TuNvoVAuxZcf5D4ywe1ji78l6crcGu4pQsMKwuX5MxAG_Hqb47J2-PDsnxOZq9P0_J-ltQ8E11SqNTwXErNMwVcMY3DA1kuBaRCK94wWOWFyUCYYd2gzFXDMqZrjTVwo0GOyc2xtwv-e4uxr9Z-G9xwshJDRaG0HniNyeToqoOPMaCpumA3EHYVZ9WecvWfsvwFvKxv-w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2429869923</pqid></control><display><type>article</type><title>Comparison and assessment of electricity generation capacity for different types of PV solar plants of 1MW in Soko banja, Serbia</title><source>Access via ProQuest (Open Access)</source><source>IngentaConnect Journals</source><creator>Pavlovic, Tomislav ; Milosavljevic, Dragana ; Radivojevic, Aleksandar ; Pavlovic, Mila</creator><creatorcontrib>Pavlovic, Tomislav ; Milosavljevic, Dragana ; Radivojevic, Aleksandar ; Pavlovic, Mila</creatorcontrib><description>This paper gives the results of the electricity generated by the fixed, one-axis and dual-axis tracking PV solar plant of 1 MW with flat PV panels made of monocrystalline silicon which is to be built in the area of Soko banja (spa in Serbia). Further on follows a description of the functioning of the fixed and one-axis and dual-axis tracking PV solar plant. For the calculation of the electricity generated by these plants PVGIS program from the Internet was used. Calculations have shown that fixed PV solar plant power of 1 MW, solar modules of monocrystalline silicon yield 1130000 kWh power output, one-axis tracking PV solar plant yields 1420000 kWh, and dual-axis tracking PV solar plant yields 1450000 kWh of electricity. Electricity generated by the fixed PV solar plant could satisfy 86% of the annual needs for the electricity of the ?Zdravljak? hotel and the special ?Novi stacionar? hospital in Soko banja. nema</description><identifier>ISSN: 0354-9836</identifier><identifier>EISSN: 2334-7163</identifier><identifier>DOI: 10.2298/TSCI110322065P</identifier><language>eng</language><publisher>Belgrade: Society of Thermal Engineers of Serbia</publisher><subject>Electricity ; Mathematical analysis ; Photovoltaic cells ; Silicon ; Tracking</subject><ispartof>Thermal science, 2011, Vol.15 (3), p.605-618</ispartof><rights>2011. This work is licensed under https://creativecommons.org/licenses/by-nc-nd/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c152p-864f17339156a1609e6685732a42961d0ab78f5a2f6a1de376d0509c9eca1f9a3</citedby><orcidid>0000-0003-4641-8149 ; 0000-0002-8176-5165 ; 0000-0002-9740-1606</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2429869923?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,4024,25753,27923,27924,27925,37012,44590</link.rule.ids></links><search><creatorcontrib>Pavlovic, Tomislav</creatorcontrib><creatorcontrib>Milosavljevic, Dragana</creatorcontrib><creatorcontrib>Radivojevic, Aleksandar</creatorcontrib><creatorcontrib>Pavlovic, Mila</creatorcontrib><title>Comparison and assessment of electricity generation capacity for different types of PV solar plants of 1MW in Soko banja, Serbia</title><title>Thermal science</title><description>This paper gives the results of the electricity generated by the fixed, one-axis and dual-axis tracking PV solar plant of 1 MW with flat PV panels made of monocrystalline silicon which is to be built in the area of Soko banja (spa in Serbia). Further on follows a description of the functioning of the fixed and one-axis and dual-axis tracking PV solar plant. For the calculation of the electricity generated by these plants PVGIS program from the Internet was used. Calculations have shown that fixed PV solar plant power of 1 MW, solar modules of monocrystalline silicon yield 1130000 kWh power output, one-axis tracking PV solar plant yields 1420000 kWh, and dual-axis tracking PV solar plant yields 1450000 kWh of electricity. Electricity generated by the fixed PV solar plant could satisfy 86% of the annual needs for the electricity of the ?Zdravljak? hotel and the special ?Novi stacionar? hospital in Soko banja. nema</description><subject>Electricity</subject><subject>Mathematical analysis</subject><subject>Photovoltaic cells</subject><subject>Silicon</subject><subject>Tracking</subject><issn>0354-9836</issn><issn>2334-7163</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNpVkL1PwzAQxS0EEqWwMltiJcUfiROPKOKjUhGVWmCMrskZuaR2sNOhG386acvCdNK7997pfoRcczYRQhd3y0U55ZxJIZjK5idkJKRMk5wreUpGTGZpogupzslFjGvGlCqKfER-Sr_pINjoHQXXUIgRY9yg66k3FFus-2Br2-_oJzoM0NvBWEMHB834QBtrDIZ9oN91GPex-TuNvoVAuxZcf5D4ywe1ji78l6crcGu4pQsMKwuX5MxAG_Hqb47J2-PDsnxOZq9P0_J-ltQ8E11SqNTwXErNMwVcMY3DA1kuBaRCK94wWOWFyUCYYd2gzFXDMqZrjTVwo0GOyc2xtwv-e4uxr9Z-G9xwshJDRaG0HniNyeToqoOPMaCpumA3EHYVZ9WecvWfsvwFvKxv-w</recordid><startdate>2011</startdate><enddate>2011</enddate><creator>Pavlovic, Tomislav</creator><creator>Milosavljevic, Dragana</creator><creator>Radivojevic, Aleksandar</creator><creator>Pavlovic, Mila</creator><general>Society of Thermal Engineers of Serbia</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>FR3</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>L6V</scope><scope>M7S</scope><scope>P5Z</scope><scope>P62</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><orcidid>https://orcid.org/0000-0003-4641-8149</orcidid><orcidid>https://orcid.org/0000-0002-8176-5165</orcidid><orcidid>https://orcid.org/0000-0002-9740-1606</orcidid></search><sort><creationdate>2011</creationdate><title>Comparison and assessment of electricity generation capacity for different types of PV solar plants of 1MW in Soko banja, Serbia</title><author>Pavlovic, Tomislav ; Milosavljevic, Dragana ; Radivojevic, Aleksandar ; Pavlovic, Mila</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c152p-864f17339156a1609e6685732a42961d0ab78f5a2f6a1de376d0509c9eca1f9a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Electricity</topic><topic>Mathematical analysis</topic><topic>Photovoltaic cells</topic><topic>Silicon</topic><topic>Tracking</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pavlovic, Tomislav</creatorcontrib><creatorcontrib>Milosavljevic, Dragana</creatorcontrib><creatorcontrib>Radivojevic, Aleksandar</creatorcontrib><creatorcontrib>Pavlovic, Mila</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>Engineering Research Database</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Materials Science Collection</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>Thermal science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pavlovic, Tomislav</au><au>Milosavljevic, Dragana</au><au>Radivojevic, Aleksandar</au><au>Pavlovic, Mila</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison and assessment of electricity generation capacity for different types of PV solar plants of 1MW in Soko banja, Serbia</atitle><jtitle>Thermal science</jtitle><date>2011</date><risdate>2011</risdate><volume>15</volume><issue>3</issue><spage>605</spage><epage>618</epage><pages>605-618</pages><issn>0354-9836</issn><eissn>2334-7163</eissn><abstract>This paper gives the results of the electricity generated by the fixed, one-axis and dual-axis tracking PV solar plant of 1 MW with flat PV panels made of monocrystalline silicon which is to be built in the area of Soko banja (spa in Serbia). Further on follows a description of the functioning of the fixed and one-axis and dual-axis tracking PV solar plant. For the calculation of the electricity generated by these plants PVGIS program from the Internet was used. Calculations have shown that fixed PV solar plant power of 1 MW, solar modules of monocrystalline silicon yield 1130000 kWh power output, one-axis tracking PV solar plant yields 1420000 kWh, and dual-axis tracking PV solar plant yields 1450000 kWh of electricity. Electricity generated by the fixed PV solar plant could satisfy 86% of the annual needs for the electricity of the ?Zdravljak? hotel and the special ?Novi stacionar? hospital in Soko banja. nema</abstract><cop>Belgrade</cop><pub>Society of Thermal Engineers of Serbia</pub><doi>10.2298/TSCI110322065P</doi><tpages>14</tpages><orcidid>https://orcid.org/0000-0003-4641-8149</orcidid><orcidid>https://orcid.org/0000-0002-8176-5165</orcidid><orcidid>https://orcid.org/0000-0002-9740-1606</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0354-9836
ispartof Thermal science, 2011, Vol.15 (3), p.605-618
issn 0354-9836
2334-7163
language eng
recordid cdi_proquest_journals_2429869923
source Access via ProQuest (Open Access); IngentaConnect Journals
subjects Electricity
Mathematical analysis
Photovoltaic cells
Silicon
Tracking
title Comparison and assessment of electricity generation capacity for different types of PV solar plants of 1MW in Soko banja, Serbia
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T01%3A57%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20and%20assessment%20of%20electricity%20generation%20capacity%20for%20different%20types%20of%20PV%20solar%20plants%20of%201MW%20in%20Soko%20banja,%20Serbia&rft.jtitle=Thermal%20science&rft.au=Pavlovic,%20Tomislav&rft.date=2011&rft.volume=15&rft.issue=3&rft.spage=605&rft.epage=618&rft.pages=605-618&rft.issn=0354-9836&rft.eissn=2334-7163&rft_id=info:doi/10.2298/TSCI110322065P&rft_dat=%3Cproquest_cross%3E2429869923%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c152p-864f17339156a1609e6685732a42961d0ab78f5a2f6a1de376d0509c9eca1f9a3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2429869923&rft_id=info:pmid/&rfr_iscdi=true