Loading…

Reliable simple zonal method of the furnace thermal calculation

With the appropriate computer program numerous thermal calculations of the furnace are done, based on the presented one-dimensional zonal method. The results of the calculation are compared with the results of measuring of testing model: Furnace chamber of steam boiler unit OP-650b in TP Kosovo-A, O...

Full description

Saved in:
Bibliographic Details
Published in:Thermal science 2005, Vol.9 (2), p.45-55
Main Author: Ivanovic, V.B.(University of Montenegro, Podgorica (Serbia and Montenegro). Faculty of Mechanical Engineering, Department of Energetics) E-mail:vladaniv@cg.ac.yu
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:With the appropriate computer program numerous thermal calculations of the furnace are done, based on the presented one-dimensional zonal method. The results of the calculation are compared with the results of measuring of testing model: Furnace chamber of steam boiler unit OP-650b in TP Kosovo-A, Obilic, Serbia and Montenegro. Comparison of the calculating results and measuring results lead to conclusion that the proposed methods is suitable for the calculation of thermal regime in a furnace chamber of large power boilers in the case when thermal resistance of deposits is great, variable in time and different in some parts. Also, the method is very suitable for analysis of real conditions in the furnace in which the conditions of furnace work are different from the projected one, as well as for simulation of various operating conditions.
ISSN:0354-9836
2334-7163
DOI:10.2298/TSCI0502045I