Reliable simple zonal method of the furnace thermal calculation
With the appropriate computer program numerous thermal calculations of the furnace are done, based on the presented one-dimensional zonal method. The results of the calculation are compared with the results of measuring of testing model: Furnace chamber of steam boiler unit OP-650b in TP Kosovo-A, O...
Saved in:
Published in: | Thermal science 2005, Vol.9 (2), p.45-55 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | With the appropriate computer program numerous thermal calculations of the furnace are done, based on the presented one-dimensional zonal method. The results of the calculation are compared with the results of measuring of testing model: Furnace chamber of steam boiler unit OP-650b in TP Kosovo-A, Obilic, Serbia and Montenegro. Comparison of the calculating results and measuring results lead to conclusion that the proposed methods is suitable for the calculation of thermal regime in a furnace chamber of large power boilers in the case when thermal resistance of deposits is great, variable in time and different in some parts. Also, the method is very suitable for analysis of real conditions in the furnace in which the conditions of furnace work are different from the projected one, as well as for simulation of various operating conditions. |
---|---|
ISSN: | 0354-9836 2334-7163 |
DOI: | 10.2298/TSCI0502045I |