Loading…

Towards Non-Contact Glucose Sensing in Aqueous Turbid Medium at ~1.1 Meters Distance

This work demonstrates a non-contact diffuse reflectance approach with a working distance of ~1.1 meters for the potential of glucose sensing. Non-contact diffuse reflectance over 1.1-1.3 micrometers was developed according to a center-illumination-area-detection (CIAD) geometry. The modeled respons...

Full description

Saved in:
Bibliographic Details
Published in:arXiv.org 2020-07
Main Authors: Piao, Daqing, O'Hara, John, Bukkapatnam, Satish, Ekin, Sabit
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Piao, Daqing
O'Hara, John
Bukkapatnam, Satish
Ekin, Sabit
description This work demonstrates a non-contact diffuse reflectance approach with a working distance of ~1.1 meters for the potential of glucose sensing. Non-contact diffuse reflectance over 1.1-1.3 micrometers was developed according to a center-illumination-area-detection (CIAD) geometry. The modeled response of diffuse reflectance in the CIAD geometry was examined with phantoms by altering independently the size of the collection geometry and the reduced scattering and absorption properties of the medium. When applied to aqueous turbid medium containing glucose control solutions with the cumulative volume varying over three orders of magnitude, a linear relationship expected for the diffuse reflectance as a function of the medium absorption/reduced-scattering property was observed for four conditions of the glucose-medium composition that differed either in the effective glucose concentration or the host medium scattering property. The cumulation of glucose up to 17.8mg/dL and 8.9mg/dL in the host medium having the same optical properties resulted in linear regression slopes of 0.0032 and 0.0030, respectively. The cumulation of the glucose up to 17.8mg/dL in an aqueous host medium that differed two folds in the reduced scattering property caused the linear regression slope to differ between 0.0032 and 0.0019. The R^2 values of all cases were all greater than 0.987. A provisional patent (US#63/053,004) has been obtained for this work.
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2439761836</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2439761836</sourcerecordid><originalsourceid>FETCH-proquest_journals_24397618363</originalsourceid><addsrcrecordid>eNqNjLsKwjAYRoMgWLTv8INzpUl6c5R6W3Qxe4ltlJSaaP4EN5_dDj6A08fhHL4JiRjnNKkyxmYkRuzTNGVFyfKcR0QI-5auQzhbk9TWeNl6OAyhtajgogxqcwdtYPMKygYEEdxVd3BSnQ4PkB4-dEVH9MohbDV6aVq1INObHFDFv52T5X4n6mPydHb8Qd_0NjgzqoZlfF0WtOIF_6_6Au6YP08</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2439761836</pqid></control><display><type>article</type><title>Towards Non-Contact Glucose Sensing in Aqueous Turbid Medium at ~1.1 Meters Distance</title><source>Publicly Available Content (ProQuest)</source><creator>Piao, Daqing ; O'Hara, John ; Bukkapatnam, Satish ; Ekin, Sabit</creator><creatorcontrib>Piao, Daqing ; O'Hara, John ; Bukkapatnam, Satish ; Ekin, Sabit</creatorcontrib><description>This work demonstrates a non-contact diffuse reflectance approach with a working distance of ~1.1 meters for the potential of glucose sensing. Non-contact diffuse reflectance over 1.1-1.3 micrometers was developed according to a center-illumination-area-detection (CIAD) geometry. The modeled response of diffuse reflectance in the CIAD geometry was examined with phantoms by altering independently the size of the collection geometry and the reduced scattering and absorption properties of the medium. When applied to aqueous turbid medium containing glucose control solutions with the cumulative volume varying over three orders of magnitude, a linear relationship expected for the diffuse reflectance as a function of the medium absorption/reduced-scattering property was observed for four conditions of the glucose-medium composition that differed either in the effective glucose concentration or the host medium scattering property. The cumulation of glucose up to 17.8mg/dL and 8.9mg/dL in the host medium having the same optical properties resulted in linear regression slopes of 0.0032 and 0.0030, respectively. The cumulation of the glucose up to 17.8mg/dL in an aqueous host medium that differed two folds in the reduced scattering property caused the linear regression slope to differ between 0.0032 and 0.0019. The R^2 values of all cases were all greater than 0.987. A provisional patent (US#63/053,004) has been obtained for this work.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Absorption ; Geometry ; Glucose ; Micrometers ; Optical properties ; Reflectance ; Regression analysis ; Scattering</subject><ispartof>arXiv.org, 2020-07</ispartof><rights>2020. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2439761836?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>776,780,25731,36989,44566</link.rule.ids></links><search><creatorcontrib>Piao, Daqing</creatorcontrib><creatorcontrib>O'Hara, John</creatorcontrib><creatorcontrib>Bukkapatnam, Satish</creatorcontrib><creatorcontrib>Ekin, Sabit</creatorcontrib><title>Towards Non-Contact Glucose Sensing in Aqueous Turbid Medium at ~1.1 Meters Distance</title><title>arXiv.org</title><description>This work demonstrates a non-contact diffuse reflectance approach with a working distance of ~1.1 meters for the potential of glucose sensing. Non-contact diffuse reflectance over 1.1-1.3 micrometers was developed according to a center-illumination-area-detection (CIAD) geometry. The modeled response of diffuse reflectance in the CIAD geometry was examined with phantoms by altering independently the size of the collection geometry and the reduced scattering and absorption properties of the medium. When applied to aqueous turbid medium containing glucose control solutions with the cumulative volume varying over three orders of magnitude, a linear relationship expected for the diffuse reflectance as a function of the medium absorption/reduced-scattering property was observed for four conditions of the glucose-medium composition that differed either in the effective glucose concentration or the host medium scattering property. The cumulation of glucose up to 17.8mg/dL and 8.9mg/dL in the host medium having the same optical properties resulted in linear regression slopes of 0.0032 and 0.0030, respectively. The cumulation of the glucose up to 17.8mg/dL in an aqueous host medium that differed two folds in the reduced scattering property caused the linear regression slope to differ between 0.0032 and 0.0019. The R^2 values of all cases were all greater than 0.987. A provisional patent (US#63/053,004) has been obtained for this work.</description><subject>Absorption</subject><subject>Geometry</subject><subject>Glucose</subject><subject>Micrometers</subject><subject>Optical properties</subject><subject>Reflectance</subject><subject>Regression analysis</subject><subject>Scattering</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqNjLsKwjAYRoMgWLTv8INzpUl6c5R6W3Qxe4ltlJSaaP4EN5_dDj6A08fhHL4JiRjnNKkyxmYkRuzTNGVFyfKcR0QI-5auQzhbk9TWeNl6OAyhtajgogxqcwdtYPMKygYEEdxVd3BSnQ4PkB4-dEVH9MohbDV6aVq1INObHFDFv52T5X4n6mPydHb8Qd_0NjgzqoZlfF0WtOIF_6_6Au6YP08</recordid><startdate>20200724</startdate><enddate>20200724</enddate><creator>Piao, Daqing</creator><creator>O'Hara, John</creator><creator>Bukkapatnam, Satish</creator><creator>Ekin, Sabit</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20200724</creationdate><title>Towards Non-Contact Glucose Sensing in Aqueous Turbid Medium at ~1.1 Meters Distance</title><author>Piao, Daqing ; O'Hara, John ; Bukkapatnam, Satish ; Ekin, Sabit</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_24397618363</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Absorption</topic><topic>Geometry</topic><topic>Glucose</topic><topic>Micrometers</topic><topic>Optical properties</topic><topic>Reflectance</topic><topic>Regression analysis</topic><topic>Scattering</topic><toplevel>online_resources</toplevel><creatorcontrib>Piao, Daqing</creatorcontrib><creatorcontrib>O'Hara, John</creatorcontrib><creatorcontrib>Bukkapatnam, Satish</creatorcontrib><creatorcontrib>Ekin, Sabit</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Piao, Daqing</au><au>O'Hara, John</au><au>Bukkapatnam, Satish</au><au>Ekin, Sabit</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>Towards Non-Contact Glucose Sensing in Aqueous Turbid Medium at ~1.1 Meters Distance</atitle><jtitle>arXiv.org</jtitle><date>2020-07-24</date><risdate>2020</risdate><eissn>2331-8422</eissn><abstract>This work demonstrates a non-contact diffuse reflectance approach with a working distance of ~1.1 meters for the potential of glucose sensing. Non-contact diffuse reflectance over 1.1-1.3 micrometers was developed according to a center-illumination-area-detection (CIAD) geometry. The modeled response of diffuse reflectance in the CIAD geometry was examined with phantoms by altering independently the size of the collection geometry and the reduced scattering and absorption properties of the medium. When applied to aqueous turbid medium containing glucose control solutions with the cumulative volume varying over three orders of magnitude, a linear relationship expected for the diffuse reflectance as a function of the medium absorption/reduced-scattering property was observed for four conditions of the glucose-medium composition that differed either in the effective glucose concentration or the host medium scattering property. The cumulation of glucose up to 17.8mg/dL and 8.9mg/dL in the host medium having the same optical properties resulted in linear regression slopes of 0.0032 and 0.0030, respectively. The cumulation of the glucose up to 17.8mg/dL in an aqueous host medium that differed two folds in the reduced scattering property caused the linear regression slope to differ between 0.0032 and 0.0019. The R^2 values of all cases were all greater than 0.987. A provisional patent (US#63/053,004) has been obtained for this work.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2020-07
issn 2331-8422
language eng
recordid cdi_proquest_journals_2439761836
source Publicly Available Content (ProQuest)
subjects Absorption
Geometry
Glucose
Micrometers
Optical properties
Reflectance
Regression analysis
Scattering
title Towards Non-Contact Glucose Sensing in Aqueous Turbid Medium at ~1.1 Meters Distance
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T23%3A56%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=Towards%20Non-Contact%20Glucose%20Sensing%20in%20Aqueous%20Turbid%20Medium%20at%20~1.1%20Meters%20Distance&rft.jtitle=arXiv.org&rft.au=Piao,%20Daqing&rft.date=2020-07-24&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E2439761836%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_journals_24397618363%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2439761836&rft_id=info:pmid/&rfr_iscdi=true