Loading…

Investigating double pulse nanoparticle enhanced laser induced breakdown spectroscopy

Several strategies have been effectively tested in the past to improve the Laser Induced Breakdown Spectroscopy (LIBS) signal, involving peculiar experimental configurations, such as Double Pulse LIBS (DP-LIBS). Recently, sample treatment has proven to be a viable and simple way to enhance the LIBS...

Full description

Saved in:
Bibliographic Details
Published in:Spectrochimica acta. Part B: Atomic spectroscopy 2020-05, Vol.167, p.105845, Article 105845
Main Authors: Poggialini, F., Campanella, B., Legnaioli, S., Pagnotta, S., Palleschi, V.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Several strategies have been effectively tested in the past to improve the Laser Induced Breakdown Spectroscopy (LIBS) signal, involving peculiar experimental configurations, such as Double Pulse LIBS (DP-LIBS). Recently, sample treatment has proven to be a viable and simple way to enhance the LIBS performances; in particular, the Nanoparticle-Enhanced LIBS (NELIBS) methodology uses a deposition of metal nanoparticles (NPs) on the sample to greatly increase the emission of the LIBS plasma. In this work, we investigate the possibility of combining, for the first time, DP-LIBS with NELIBS. The chosen set-up uses two parallel non-collinear laser pulses to ensure the activation of NPs during both pulses, while maintaining the low-pressure environment typical of DP-LIBS. The two laser beams are spatially separated so that the second beam is focused within the shock wave generated by the first one. This configuration allows the exploitation of the combined enhancement of both DP-LIBS and NELIBS. Several tests on copper targets have been performed to determine the best set-up for the maximum magnitude of the signal enhancement by adjusting different parameters such as pulse energies and offset distances. Commercially available silver NPs and NPs prepared by pulsed laser ablation in liquid have been tested and their performances compared with standard DP-LIBS. [Display omitted] •The possibility of combining Double Pulse LIBS and NELIBS has been investigated.•A novel approach based on Spatially Offset (SO) laser pulses has been implemented.•SO-DP-NELIBS has been proven capable of enhancing DP-LIBS performances.
ISSN:0584-8547
1873-3565
DOI:10.1016/j.sab.2020.105845