Comparison of various shear connectors for improved structural performance in CFS concrete composite slabs

•Development of CFS concrete composite slabs using different shear connectors.•No interaction, partial interaction and full interaction cases were studied.•Strength, stiffness, displacement ductility characteristics were investigated.•Substantial improvement in the strength-to-weight ratio and cost...

Full description

Saved in:
Bibliographic Details
Published in:Engineering structures 2020-10, Vol.220, p.111008, Article 111008
Main Authors: Dar, M. Adil, Subramanian, N., Dar, A.R., Ghowsi, Ahmad Fayeq, Sidiqui, Faizan, Fayaz, Sana, Mir, M. Shoaib
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•Development of CFS concrete composite slabs using different shear connectors.•No interaction, partial interaction and full interaction cases were studied.•Strength, stiffness, displacement ductility characteristics were investigated.•Substantial improvement in the strength-to-weight ratio and cost reduction was achieved.•Flexural strengths and degree of shear interaction was investigated. Composite sections comprising of wisely selected materials has gained popularity in the construction industry, as it may result in utilizing the advantages of two different materials thus resulting in efficient sections, which will not only reduce the dead loads but also provide economical solutions. Cold-formed steel (CFS) concrete composites have been used extensively in building construction, as the inherent weakness of local buckling in the CFS sections under compressive loading is taken care of by the concrete, which has significant compressive strength. This study presents an experimental investigation performed on full-scale simply supported CFS concrete composite slabs under four-point monotonic loading, with an aim to evaluate the effectiveness of the different shear connectors being adopted. The shear connectors were so adopted that they could provide the least possible interaction (for representing the no-interaction condition), partial-interaction and full-interaction between the steel deck sheet and the concrete slab. The performance of the various shear connectors was assessed in terms of strength, stiffness and ductility ratio. Cracking as well as end slippage were also studied. The test results were compared with a conventional RC slab, in terms of structural performance as well as cost and strength-to-weight ratio. The flexural test strengths were compared with the design strength quantified using the Euro Code. The degree of shear interaction was also investigated. It was found that the CFS concrete composite slabs not only performed better structurally but economically as well, in addition to providing significant strength-to-weight ratio, when compared to a conventional RC slab.
ISSN:0141-0296
1873-7323