Loading…
A Liquid Membrane Mercury Selective Electrode Based on 2-(N-pipyridino Methyl)-1-Cyano Cyclohexanol as a Novel Neutral Carrier
2-(N-pipyridino methyl)-1-cyano cyclohexanol was synthesized, characterized and used as an ionophore in construction of polyvinyl chloride ( PVC ) potentiometric sensor for Hg 2+ determination. The best result was obtained with membrane composition of PVC (29%), sodium tetraphenylborate as ionic add...
Saved in:
Published in: | Journal of analytical chemistry (New York, N.Y.) N.Y.), 2020-10, Vol.75 (10), p.1340-1347 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | 2-(N-pipyridino methyl)-1-cyano cyclohexanol was synthesized, characterized and used as an ionophore in construction of polyvinyl chloride (
PVC
) potentiometric sensor for Hg
2+
determination. The best result was obtained with membrane composition of PVC (29%), sodium tetraphenylborate as ionic additive (1%), 2-(N-pipyridino methyl)-1-cyano cyclohexanol (12%) and dibutylphthalate (58%). The designed electrode showed an acceptable Nernstian slope (29.1 mV/decade) for Hg
2+
over a wide concentration range from 5 × 10
–7
to 1 × 10
–2
M with a detection limit of 2.5 × 10
–7
M. The potential response was independent from pH in the range of 6.0–9.0 and the sensor response time was relatively short (~25 s). The sensor performance was invariable for at least 6 weeks. Electrode selectivity was evaluated by matched potential method. Finally, the proposed sensor was used as an indicator electrode in potentiometric titration of Hg
2+
with ethylenediaminetetraacetic acid and in direct determination of mercury(II) in aqueous samples with admissible accuracy and high reproducibility. |
---|---|
ISSN: | 1061-9348 1608-3199 |
DOI: | 10.1134/S106193482010010X |