Loading…

Numerical simulations and optimization of solar air heaters

•The empirical correlations are developed to obtain Nu number and friction factor.•The designs of rectangular section finned surfaces are optimized.•Maximum THP of 2.77 is obtained at optimum values of input parameters.•The optimal size of rectangular section fin has been calculated. Different surfa...

Full description

Saved in:
Bibliographic Details
Published in:Applied thermal engineering 2020-11, Vol.180, p.115744, Article 115744
Main Authors: Korpale, V.S., Deshmukh, S.P., Mathpati, C.S., Dalvi, V.H.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c358t-6a65df01f5ad266b690ebff9cf8b9511d4c4995cf283ee344fa845108f605c303
cites cdi_FETCH-LOGICAL-c358t-6a65df01f5ad266b690ebff9cf8b9511d4c4995cf283ee344fa845108f605c303
container_end_page
container_issue
container_start_page 115744
container_title Applied thermal engineering
container_volume 180
creator Korpale, V.S.
Deshmukh, S.P.
Mathpati, C.S.
Dalvi, V.H.
description •The empirical correlations are developed to obtain Nu number and friction factor.•The designs of rectangular section finned surfaces are optimized.•Maximum THP of 2.77 is obtained at optimum values of input parameters.•The optimal size of rectangular section fin has been calculated. Different surface modification techniques have been used for enhancement of heat transfer from absorber plates of solar air heaters. It is necessary to have accurate values of design parameters within the operational window while designing the heat transfer equipments. The present work is focused on the development of empirical correlations and evaluation of maximum thermohydraulic performance of a rectangular section ribs installed in solar air heaters considering all the design combinations within the given range of input parameters. It is prescribed by design of experiment algorithms particularly with response surface methodology considering four input parameters viz., Reynolds number ranging from 4000 to 20000, relative rib pitch ranging from 5 to 60, relative rib height ranging from 0.065 to 0.252 and relative rib width ranging from 0.5 to 10. The maximum THP obtained is 2.77 at Reynolds number 20000, relative rib pitch 17.22, relative rib height 0.044 and relative rib height 0.5. The optimal values of design parameters have been verified with CFD simulations and experiments. The errors are within acceptable limit proving the accuracy of empirical correlations used for the design of solar artificial air heater and proper selection of model equations.
doi_str_mv 10.1016/j.applthermaleng.2020.115744
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2461032412</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1359431120332269</els_id><sourcerecordid>2461032412</sourcerecordid><originalsourceid>FETCH-LOGICAL-c358t-6a65df01f5ad266b690ebff9cf8b9511d4c4995cf283ee344fa845108f605c303</originalsourceid><addsrcrecordid>eNqNkE9PwzAMxSMEEmPwHSrBtSPOv7WCC5oYICG4wDnKUoelapuStEjw6ekYF26cbNnvPcs_Qi6ALoCCuqwXpu-bYYuxNQ12bwtG2bQCuRTigMygWPJcKqoOp57LMhcc4JicpFRTCqxYihm5ehpbjN6aJku-HRsz-NClzHRVFvrBt_7rZ5IFl6XQmJgZH7MtmgFjOiVHzjQJz37rnLyub19W9_nj893D6uYxt1wWQ66MkpWj4KSpmFIbVVLcOFdaV2xKCVAJK8pSWscKjsiFcKYQEmjhFJWWUz4n5_vcPob3EdOg6zDGbjqpmVBAORPAJtX1XmVjSCmi0330rYmfGqje4dK1_otL73DpPa7Jvt7bcfrkw2PUyXrsLFY-oh10Ffz_gr4BeiN8Fw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2461032412</pqid></control><display><type>article</type><title>Numerical simulations and optimization of solar air heaters</title><source>Elsevier</source><creator>Korpale, V.S. ; Deshmukh, S.P. ; Mathpati, C.S. ; Dalvi, V.H.</creator><creatorcontrib>Korpale, V.S. ; Deshmukh, S.P. ; Mathpati, C.S. ; Dalvi, V.H.</creatorcontrib><description>•The empirical correlations are developed to obtain Nu number and friction factor.•The designs of rectangular section finned surfaces are optimized.•Maximum THP of 2.77 is obtained at optimum values of input parameters.•The optimal size of rectangular section fin has been calculated. Different surface modification techniques have been used for enhancement of heat transfer from absorber plates of solar air heaters. It is necessary to have accurate values of design parameters within the operational window while designing the heat transfer equipments. The present work is focused on the development of empirical correlations and evaluation of maximum thermohydraulic performance of a rectangular section ribs installed in solar air heaters considering all the design combinations within the given range of input parameters. It is prescribed by design of experiment algorithms particularly with response surface methodology considering four input parameters viz., Reynolds number ranging from 4000 to 20000, relative rib pitch ranging from 5 to 60, relative rib height ranging from 0.065 to 0.252 and relative rib width ranging from 0.5 to 10. The maximum THP obtained is 2.77 at Reynolds number 20000, relative rib pitch 17.22, relative rib height 0.044 and relative rib height 0.5. The optimal values of design parameters have been verified with CFD simulations and experiments. The errors are within acceptable limit proving the accuracy of empirical correlations used for the design of solar artificial air heater and proper selection of model equations.</description><identifier>ISSN: 1359-4311</identifier><identifier>EISSN: 1873-5606</identifier><identifier>DOI: 10.1016/j.applthermaleng.2020.115744</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Aerodynamics ; Air heaters ; Algorithms ; Computational fluid dynamics ; Computer simulation ; Design parameters ; Fluid flow ; Heat transfer ; Heaters ; Mathematical models ; Multiple parameters optimization ; Optimization ; Response surface methodology ; Reynolds number ; Solar air heaters ; Solar energy ; Thermo-hydraulic performance (THP)</subject><ispartof>Applied thermal engineering, 2020-11, Vol.180, p.115744, Article 115744</ispartof><rights>2020 Elsevier Ltd</rights><rights>Copyright Elsevier BV Nov 5, 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c358t-6a65df01f5ad266b690ebff9cf8b9511d4c4995cf283ee344fa845108f605c303</citedby><cites>FETCH-LOGICAL-c358t-6a65df01f5ad266b690ebff9cf8b9511d4c4995cf283ee344fa845108f605c303</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,778,782,27911,27912</link.rule.ids></links><search><creatorcontrib>Korpale, V.S.</creatorcontrib><creatorcontrib>Deshmukh, S.P.</creatorcontrib><creatorcontrib>Mathpati, C.S.</creatorcontrib><creatorcontrib>Dalvi, V.H.</creatorcontrib><title>Numerical simulations and optimization of solar air heaters</title><title>Applied thermal engineering</title><description>•The empirical correlations are developed to obtain Nu number and friction factor.•The designs of rectangular section finned surfaces are optimized.•Maximum THP of 2.77 is obtained at optimum values of input parameters.•The optimal size of rectangular section fin has been calculated. Different surface modification techniques have been used for enhancement of heat transfer from absorber plates of solar air heaters. It is necessary to have accurate values of design parameters within the operational window while designing the heat transfer equipments. The present work is focused on the development of empirical correlations and evaluation of maximum thermohydraulic performance of a rectangular section ribs installed in solar air heaters considering all the design combinations within the given range of input parameters. It is prescribed by design of experiment algorithms particularly with response surface methodology considering four input parameters viz., Reynolds number ranging from 4000 to 20000, relative rib pitch ranging from 5 to 60, relative rib height ranging from 0.065 to 0.252 and relative rib width ranging from 0.5 to 10. The maximum THP obtained is 2.77 at Reynolds number 20000, relative rib pitch 17.22, relative rib height 0.044 and relative rib height 0.5. The optimal values of design parameters have been verified with CFD simulations and experiments. The errors are within acceptable limit proving the accuracy of empirical correlations used for the design of solar artificial air heater and proper selection of model equations.</description><subject>Aerodynamics</subject><subject>Air heaters</subject><subject>Algorithms</subject><subject>Computational fluid dynamics</subject><subject>Computer simulation</subject><subject>Design parameters</subject><subject>Fluid flow</subject><subject>Heat transfer</subject><subject>Heaters</subject><subject>Mathematical models</subject><subject>Multiple parameters optimization</subject><subject>Optimization</subject><subject>Response surface methodology</subject><subject>Reynolds number</subject><subject>Solar air heaters</subject><subject>Solar energy</subject><subject>Thermo-hydraulic performance (THP)</subject><issn>1359-4311</issn><issn>1873-5606</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNqNkE9PwzAMxSMEEmPwHSrBtSPOv7WCC5oYICG4wDnKUoelapuStEjw6ekYF26cbNnvPcs_Qi6ALoCCuqwXpu-bYYuxNQ12bwtG2bQCuRTigMygWPJcKqoOp57LMhcc4JicpFRTCqxYihm5ehpbjN6aJku-HRsz-NClzHRVFvrBt_7rZ5IFl6XQmJgZH7MtmgFjOiVHzjQJz37rnLyub19W9_nj893D6uYxt1wWQ66MkpWj4KSpmFIbVVLcOFdaV2xKCVAJK8pSWscKjsiFcKYQEmjhFJWWUz4n5_vcPob3EdOg6zDGbjqpmVBAORPAJtX1XmVjSCmi0330rYmfGqje4dK1_otL73DpPa7Jvt7bcfrkw2PUyXrsLFY-oh10Ffz_gr4BeiN8Fw</recordid><startdate>20201105</startdate><enddate>20201105</enddate><creator>Korpale, V.S.</creator><creator>Deshmukh, S.P.</creator><creator>Mathpati, C.S.</creator><creator>Dalvi, V.H.</creator><general>Elsevier Ltd</general><general>Elsevier BV</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>20201105</creationdate><title>Numerical simulations and optimization of solar air heaters</title><author>Korpale, V.S. ; Deshmukh, S.P. ; Mathpati, C.S. ; Dalvi, V.H.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c358t-6a65df01f5ad266b690ebff9cf8b9511d4c4995cf283ee344fa845108f605c303</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Aerodynamics</topic><topic>Air heaters</topic><topic>Algorithms</topic><topic>Computational fluid dynamics</topic><topic>Computer simulation</topic><topic>Design parameters</topic><topic>Fluid flow</topic><topic>Heat transfer</topic><topic>Heaters</topic><topic>Mathematical models</topic><topic>Multiple parameters optimization</topic><topic>Optimization</topic><topic>Response surface methodology</topic><topic>Reynolds number</topic><topic>Solar air heaters</topic><topic>Solar energy</topic><topic>Thermo-hydraulic performance (THP)</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Korpale, V.S.</creatorcontrib><creatorcontrib>Deshmukh, S.P.</creatorcontrib><creatorcontrib>Mathpati, C.S.</creatorcontrib><creatorcontrib>Dalvi, V.H.</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Applied thermal engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Korpale, V.S.</au><au>Deshmukh, S.P.</au><au>Mathpati, C.S.</au><au>Dalvi, V.H.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Numerical simulations and optimization of solar air heaters</atitle><jtitle>Applied thermal engineering</jtitle><date>2020-11-05</date><risdate>2020</risdate><volume>180</volume><spage>115744</spage><pages>115744-</pages><artnum>115744</artnum><issn>1359-4311</issn><eissn>1873-5606</eissn><abstract>•The empirical correlations are developed to obtain Nu number and friction factor.•The designs of rectangular section finned surfaces are optimized.•Maximum THP of 2.77 is obtained at optimum values of input parameters.•The optimal size of rectangular section fin has been calculated. Different surface modification techniques have been used for enhancement of heat transfer from absorber plates of solar air heaters. It is necessary to have accurate values of design parameters within the operational window while designing the heat transfer equipments. The present work is focused on the development of empirical correlations and evaluation of maximum thermohydraulic performance of a rectangular section ribs installed in solar air heaters considering all the design combinations within the given range of input parameters. It is prescribed by design of experiment algorithms particularly with response surface methodology considering four input parameters viz., Reynolds number ranging from 4000 to 20000, relative rib pitch ranging from 5 to 60, relative rib height ranging from 0.065 to 0.252 and relative rib width ranging from 0.5 to 10. The maximum THP obtained is 2.77 at Reynolds number 20000, relative rib pitch 17.22, relative rib height 0.044 and relative rib height 0.5. The optimal values of design parameters have been verified with CFD simulations and experiments. The errors are within acceptable limit proving the accuracy of empirical correlations used for the design of solar artificial air heater and proper selection of model equations.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><doi>10.1016/j.applthermaleng.2020.115744</doi></addata></record>
fulltext fulltext
identifier ISSN: 1359-4311
ispartof Applied thermal engineering, 2020-11, Vol.180, p.115744, Article 115744
issn 1359-4311
1873-5606
language eng
recordid cdi_proquest_journals_2461032412
source Elsevier
subjects Aerodynamics
Air heaters
Algorithms
Computational fluid dynamics
Computer simulation
Design parameters
Fluid flow
Heat transfer
Heaters
Mathematical models
Multiple parameters optimization
Optimization
Response surface methodology
Reynolds number
Solar air heaters
Solar energy
Thermo-hydraulic performance (THP)
title Numerical simulations and optimization of solar air heaters
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T23%3A38%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Numerical%20simulations%20and%20optimization%20of%20solar%20air%20heaters&rft.jtitle=Applied%20thermal%20engineering&rft.au=Korpale,%20V.S.&rft.date=2020-11-05&rft.volume=180&rft.spage=115744&rft.pages=115744-&rft.artnum=115744&rft.issn=1359-4311&rft.eissn=1873-5606&rft_id=info:doi/10.1016/j.applthermaleng.2020.115744&rft_dat=%3Cproquest_cross%3E2461032412%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c358t-6a65df01f5ad266b690ebff9cf8b9511d4c4995cf283ee344fa845108f605c303%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2461032412&rft_id=info:pmid/&rfr_iscdi=true